RETAIN THIS OPERATING MANUAL WITH BOILER. DO NOT DISCARD 

 

 

Electra Steam, Inc.

Instruction Manual for JR06 Steam Generator, JG- and JJ- Models

 

READ THIS FIRST: 

The safeguards and instructions appearing on these pages
are not meant to cover all possible situations that may occur. 

Understand that common sense, caution, and care are
factors which cannot be built into any product. The person
operating the unit must supply these factors.

Read all instructions before installation and operation.

Ensure that the blowdown valve is properly and safely piped.

Do not position your face or body over the fill funnel.

Stand clear of safety valve and scalding steam.

Never open the fill valve when unit is under pressure.

Valves and pipes are hot when under pressure or heating
up. Do not touch!

IF A LEAK IS EVIDENT:  

Steam fittings can become loose during
shipment and subsequently leak. It is easy to
resolve these leaks if you are careful: 

1.

Ensure that the boiler is cold,
drained and has no pressure or
electricity.

2.

Tighten leaking packing nut gently a
quarter of a turn. Do not over tighten,
as this will result in gauge glass
breakage or in valve stem freezing
and valve failure.

3.

Fill boiler and operate normally.

4.

Observe for more leaks and repeat
steps 1 and 2 as required.

7

3

8

1

11 

9

12

10

ASME 

Plate behind

this panel

ASME 
CSD-1 
CRN

1. General

The Reimers JR-series boiler is a portable, hand-filled steam 
generator with a total of 2 gallon capacity, for operation at pressures
from 5 to 85 psi. Designed to the ASME/CSD-1 Boiler Code and 
registered with the National Board of Boiler Inspectors, it is safe
when installed, maintained, and used properly.  
Standard JG-Model equipment includes: Steam pressure gauge (1),
steam valve (2), blowdown valve (3), water-fill funnel (4), check valve 
(5), water fill valve (6) safety valve (7), water level gauge (8),
electronic boiler control (9) and power cord (10). 
JJ-Model equipment includes in addition to standard model
equipment: Steam jet with electric solenoid valve (11) and foot switch
(12). 

Adjustments: 

All controls have been set at the factory and should

require no adjustments 

(Open gauge glass valves)

Modification/Misuse: 

Any modification or misuse of this unit could

result in a dangerous situation. Reimers Electra Steam, Inc. is not
liable for any product that has been modified or improperly used. 

Registration: 

Most states and cities require boiler

registration/inspection. Check with local government authorities. 

Repair: 

Only experienced personnel must attempt repair of this unit.

For repair instructions see chapter 5 of this instruction manual.