Safety information
Safety precautions:
Before commencing mounting work on roofs, it must
be ensured in all cases that the non-personal fall protection and fall-arrest
systems required by DIN 18338 (Roof Covering and Roof Sealing Works)
and DIN 18451 (Scaffolding Works) are in place. Other country-speci
fi
c
regulations must be observed!
If non-personal fall protection or fall-arrest systems cannot be installed for
technical reasons, all personnel must be secured by means of suitable
safety harnesses!
Only use safety harnesses (safety belts, lanyards and straps, shock
absorbers, fall arresters) that were tested and certi
fi
ed by authorized
testing bodies.
If non-personal fall protection or fall-arrest systems are not provided,
orking without the use of suitable safety harnesses may lead to falls from
heights and therefore cause serious or lethal injuries!
Ladders not properly secured against sinking in, sliding or falling over may
lead to dangerous falls!
Whenever you are near live overhead electric cables where contact is
possible, only work if:
- it is ensured that they are voltage-free and this is secured for the
duration of work.
- the live parts are secured by covering them or cordoning them off.
- the prescribed safety distances are maintained.
Voltage radius
:
3 m......................1000 - 11000 V
4 m......................11000V - 22000 V
5 m..................... 22000 V - 38000 V
> 5m in case of unknown voltages
The manufacturer hereby guarantees to take back products identi
fi
ed with
an eco-label and to recycle the materials used.Only the heat transfer medi-
um speci
fi
ed may be used!
Safety harnesses should be
fi
xed above the users whenever possible.
Safety harnesses should only be fastened to suf
fi
ciently load-bearing
structures or
fi
xing points!
Never use damaged ladders (e.g., wooden ladders with split runners
or rungs, or bent or buckled metal ladders). Never try to repair broken
runners, rungs or steps on wooden ladders!
Ensure that ladders are put up safely. Observe the correct leaning angle
(68° - 75°). Prevent ladders from sliding, falling over or sinking into
the ground (e.g. using wider feet, feet suited to the ground or hooking
devices).
Only lean ladders against secure points. Secure ladders in traf
fi
c areas by
suitable cordoning.
Contact with live electric overhead cables can be lethal.
Wear protective goggles when drilling and handling evacuated tube collec-
tors (danger of implosion)!
Wear safety shoes when carrying out installation work!
Wear cut-proof safety gloves when mounting collectors and handling
evacuated tube collectors (danger of implosion)!
Wear a helmet when carrying out installation work!
1
m......................
Voltages up to
1000 V
Содержание Ashburn KPI1
Страница 1: ...EN ver 1 1 Installation and Operation Manual KPI1 Inroof Solar Collector 6904180...
Страница 5: ...5 Transport note ATTENTION Do not lift collectors by the connections or the screw threads...
Страница 24: ...24 Connection diagram Connecting bend Installation battens Attachment brackets...
Страница 27: ...27 Notes...
Страница 28: ...02 2012 REGULUS spol s r o Do Kout 1897 3 CZ 143 00 Praha 4 http www regulus eu E mail sales regulus cz...