Regner 6000.155.369.350 Скачать руководство пользователя страница 1

RA67

IN-LINE ACTUATOR SERIES

User Manual

www.regner.es

Содержание 6000.155.369.350

Страница 1: ...RA67 IN LINE ACTUATOR SERIES User Manual www regner es...

Страница 2: ...ights reserved Specifications are subject to change without notice It is the responsibility of the user to determine the suitability of REGNER products for a specific application No part of this publi...

Страница 3: ...RA67 IN LINE ACTUATOR SERIES 3 00 Contents 01 Preface 4 02 Safety 4 03 Warranty 5 04 Specifications 6 05 Installation 9 06 Maintenance 10 07 Troubleshooting 11 08 Application Policy 11 09 Contact 11...

Страница 4: ...the main power supply when the actuator is not in use to prevent unintentional operation Do not exert force on the side of the actuator Make sure that the cable cannot be pressed upon pulled or subje...

Страница 5: ...olent or abra sive treatment Nonconformities due to reasonable wear and tear of the actuator over time such as faded paint are excluded from warranty REGNER reserves the right to request the return of...

Страница 6: ...o center mm 370 cable length mm M10 mounting hole diameter AEL feedback option Analogic Encoder feedback Limit switches 02 Actuator specifications Basic specifications and actuator features 03 Batch N...

Страница 7: ...with position memory and digital output and it can convert the output signal to an analog signal hall potentiome ter thanks to its advanced electronics Furthermore there is available a pulse hall PWM...

Страница 8: ...led so that the force of the load is exerted on the center of the axis of the actuator Excessive off center loads may cause bending and lead to premature failure To prevent premature wear make sure th...

Страница 9: ...nstalling anc connecting the actuator Make sure that the power supply and the cables can handle the maximum motor current The electronic limit switches will automatically switch off the actuator when...

Страница 10: ...Please contact REGNER Excessive electrici ty consumption 1 Misaligned or excessive load A Align or re duce the load B Run the actuator with no load C Please contact REGNER The motor runs but the spin...

Страница 11: ...sehold or industrial equipment for example REGNER cannot know and check all the conditions in which REGNER products are installed and used The suitability and functional ity of a REGNER product as wel...

Страница 12: ...RA57ACTUATOR Ripoll s 4 17181 Aiguaviva Girona SPAIN Tel 34 972 476 911 Fax 34 972 475 803 info regner es www regner es...

Отзывы: