INSTRUCTION

RCW-M32

IN20015 REV. C, 2019-05-28

C

Caauuttiioonn!! Read and understand the instruction before using the product.

C

Caauuttiioonn!! Ensure that the installation complies with local safety

regulations.

C

Caauuttiioonn!! Before installation or maintenance, the power supply should first

be disconnected. Installation or maintenance of this unit should only be
carried out by qualified personnel. The manufacturer is not responsible
for any eventual damage or injury caused by inadequate skills during instal-
lation, or through removal of or deactivation of any security devices.

Technical Data

Supply voltage

24 V AC/DC (21…27 V AC/DC)

Frequency

868 MHz

Protection class

IP54

Ambient temperature

-10…+50 °C

Ambient humidity

Max. 85 % RH, non-condensing

Dimensions, external (WxHxD)

120 x 112 x 40 mm

Internal serial port, type

RS485, isolated

Internal serial port, built-in protocol

Modbus

Internal serial port, communication
speed

1200 / 2400 / 9600 (default) / 19200 /
38400 /57600 bps

Internal serial port, parity

None (default) / even / odd

Internal serial port, stop bit

1 stop bit (default) / 2 stop bit

Installation

1. Lift the lid to access the terminals.

2. Connect the receiver to the master controller via the RS485

terminal.

3. Connect the receiver to the supply voltage. The display will beep

once and two small LED lights will start blinking on the display.

4. Mount the receiver on any flat surface. If it is installed in a humid

environment, vertical mounting is recommended.

When the receiver is powered on it will automatically forward signals
received from the paired sensors and detectors to the controller.

Wiring

Number

Description

1

Display

2

Joystick with

Menu button

3

Supply voltage terminal

4

RS485 terminal

Settings

The joystick is used to manoeuvre through the channels (see

Table 1

).

For each selected channel four different values are shown subsequently
in the display:

1. Current channel, e.g. 01

2. Received signal strength indicator (RSSI),

S.1…9

S.

= signal strength,

1

= weak signal,

9

= strong signal

S.-

= no sensor is paired on the selected channel

Note that the signal strength abbreviation

S.

should not be mistaken

for number

5

.

3. Value 1 for the sensor or detector (if available),

0

99

. If both value

1 and 2 are available, value 1 always shows the temperature.

4. Value 2 for the sensor or detector (if available),

0

99

. Value 2 can

for example show the humidity.

Table 1 Navigate the channels

Description

Manoeuvre

Time

Activate the display

Press the

Menu

button

1 s

Move to the subsequent channel.

Push UP

1 s

Move to the preceding channel.

Push DOWN

1 s

Jump 8 channels forward.

Push RIGHT

1 s

Leave the menu and inactivate the display.

Push LEFT

3 s

Many default settings can be changed via the display. The joystick is used
to navigate within the menu as shown in

Table 2

. To enter the menu,

press the

Menu button

4 s when the display is inactive. Six levels are

available:

1. A: Pair and unpair sensors

2. B: Modbus addresses, as hexadecimal numbers

3. C: Communication speed (baud rate)

4. D: Parity and stop bit

5. E: Selected frequency

6. F: Current software version

Table 2 Navigating the menu

Description

Manoeuvre

Time

Enter into the menu

Press the

Menu button

when

the display is inactive

4 s

Move between the different levels in
the menu (A-F)

Push UP or DOWN

1 s

Enter into one level

Press the

Menu button

1 s

Move between different values within
one level

Push UP or DOWN

1 s

Leave the menu and inactivate the
display.

Push LEFT

3 s

A complete description on how to read and modify the settings, both via
the display and via Modbus, can be found in the Modbus variable list.

4

3

GND A- B+

G

G0

1

2

RCW-M32