Regent Lighting Solutions Olympia Pro Скачать руководство пользователя страница 1

1

2

www.regentlight.co.za

www.regentlight.co.za

INSTALLATION INSTRUCTIONS

ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED  ELECTRICIAN

ALL CONNECTIONS TO BE CARRIED OUT BY A QUALIFIED  ELECTRICIAN

1

PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.

PLEASE READ CAREFULLY BEFORE STARTING INSTALLATION.

Electrical products can cause death, injury, or damage to property. 

Installation of this product must be carried out by a qualified electrician, in 

compliance with SANS 10142 or corresponding regulations of the country of 

installation. On completion of installation, the Certificate of Compliance must 

be updated.

Olympia pro

WARNING

Electronic Control Device

Electronic Control Device

WARNING

3 - 13 MAIN REEF SERVICE ROAD, CORNER 

SPRINGBOK AND MAIN REEF ROAD, INDUSTRIA, 

JOHANNESBURG. SOUTH AFRICA.

TEL : +27 11 474 0171

www.regentlight.co.za

REGENT LIGHTING A DIVISION 

OF WAHL INDUSTRIES. 

Save These Instructions for Future Reference

Save These Instructions for Future Reference

ELECTRIC SHOCK 
HAZARD

This equipment is to be
serviced by trained
personnel only.

ELECTRIC SHOCK 
HAZARD

This equipment is to be
serviced by trained
personnel only.

Surface mounted and Suspended option available

 

Olympia pro recessed mounted

DO NOT CONNECT THE FITTING LIVE

June 2021

2

3

L Bracket

Ÿ

If the main supply power (live) 

is on, it will cause damage to 

the luminaries.

Requirements:

Ÿ

Be sure the electricity to the 

system you are working on is  

isolated.

1. Fitting as supplied in Regent 

Lighting Solutions box.

 

 

For non user replaceable light source: The light source contained in this luminaire 

shall only be replacedby the manufacturer or his/her service 

agent or a similar qualied person

1

DO NOT PLUG 

(CONNECT) WHEN 

LIVE AS IT WILL CAUSE 

DAMAGE TO THE 

LUMINAIRE.

2. Hole cut out  365 x 365 mm 
on the ceiling            

3. Insert Olympia frame and 
secure onto soft surface using  
L brackets onto frame.

Regent  Lighting  reserves  the  right  to  change  specifications  modify  designs  and  discontinue  items  without 

incurring  obligation  and  whilst  every  effort  is  made  to  ensure  that  descriptions,  specifications  and  other 

information in this catalogue are correct, no warranty is given in respect thereof and the company shall not be 

liable for any error therein.

TURN OFF POWER  

AT CIRCUIT BREAKER OR FUSE AND TEST THAT THE POWER IS OFF BEFORE WIRING

WARNING: 

TO AVOID FIRE, SHOCK OR DEATH

ALL LUMINAIRES SUPPLIED AND TO BE INSTALLED ABOVE AND BELOW 5 METERS ARE IN COMPLIANCE WITH SANS 

60598 SECTION 3.5.6 ACCORDING TO THE MANUFACTURER GUARANTEE AND WARRANTY

Sensor Version 
optional

365

365

Ceiling cut out

Отзывы: