safety decal
This is a copy of the label that accompanies each
P36E Zero Clearance Direct Vent Gas Fireplace.
We have printed a copy of the contents here for
your review. The safety label is located on the
front inside base of the unit.
NOTE:
Regency units are constantly being
improved. Check the label on the unit and if
there is a difference, the label on the unit is the
correct one.
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible con
-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Copy of the Safety Decal
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
360
360
DOOR SEAL: Please
check that the door is
properly sealed
Minimum Clearances to Combustibles /
Degagement Minimum De Materiaux Combustibles
Serial No./ No de serie
919-469a
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.
Duplicate S/N
0" Clearance to
combustibles from:
Sides, bottom and rear of unit
Mantel Clearances from Top:
(A) Min. 12" (305mm)
Side Wall Clearance
from Side Facing
B) 6"
Alcove Clearances:
Max. Depth 36" (914mm)
Min. Width 48" (1219mm),
Min. Height 72" (1229mm)
Minimum Vent Clearances:
Horizontal Top 2" (51mm)
Horizontal Side 1-1/2" (38mm)
Horizontal Bottom 1-1/2" (38mm)
Vertical Vent 1-1/4" (32mm)
(
See Instruction Manual for detailed instructions)
É
É
QUIP A L'UISINE POUR GAZ PROPANE
PROPANE GAS: Model P36E-LP10
11” WC/C.E. (2.73 kPa)
10" WC/C.E. (2.49 kPa)
6.4" WC/C.E. (1.59 kPa)
Minimum supply pressure
Manifold pressure High
Manifold pressure Low
Pression d'allimentation minimum
Pression la tubulure d' chappement lev e
à
é
é é
Pression la tubulure d' chappement basse
à
é
28,500 Btu for altitude 0 - 4500 ft.
Maximum Input
Minimum Input
Orifice size
Altitude
28,500 Btu/h (8.35 Kw/h)
22,000 Btu/h (6.44 Kw/h)
#52 DMS
0-4500 ft/pi (0-1372m)
D bit Calorifique maximum
é
D bit Calorifique minimum
é
Dimensions de l'orifice
L'altitude
NATURAL GAS: Model P36E-NG10
Minimum supply pressure
Manifold pressure high
Manifold pressure low
Orifice size
Minimum input
Maximum input
Altitude
APPAREIL FONCTIONNANT AU NATURAL GAS
CONCU POUR ETRE POELE: Mod le P36E-NG10
é
Pression d'allimentation minimum
Pression à la tubulure d' chappement lev e
é
é é
Pression à la tubulure d' chappement basse
é
Grandeur de l'injecteur
D bit Calorifique minimum selon
é
D bit Calorifique maximum selon
é
l'altitude
5” WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0..87 kPa)
1.6" WC/C.E. (0.27 kPa)
# 37 DMS
19,500 Btu/h (5.71 kW)
29,500 Btu/h (8.65 kW)
0-4500 ft/pi (0-1372 m)
Part #: 919-469a
Colour: Everything black on grey except what is highlighted is printed red.
Material: 2 ml silver matt polyester (DPM SMS)
Size: 100%
Oct 23/2014: Created decal.
Apr.27/15: Rev.A-Added screen part #
*Printer: Continue number sequence from 918-853 - do not restart at 0
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the United
States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard
This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual
for details.
Fan (Part # 438-917) Option: HeatWave Kit # 946-556
Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.
Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si ces
normes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.
Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.
This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.
For use with glass doors certified with the appliance only Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil
Made in Canada/
Fabrique au Canada
FPI Fireplace Products International Ltd.Delta, BC, Canada
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -
Listed:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
CANADA and U.S.A.
é
Certified to:
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2014/ CSA 2.33-2014
Tested to:
4001172
B
B
32"
Ceiling
W
all
W
all
A
ELECTRICAL SUPPLY/ALIMENTATION ELECTRIQUE:
115V_60HZ less than/moins de 2 AMP
For Use Only with Barrier (Part #515-005 with Vignette) or (Part #515-929 Installed with Louvers) Follow installation instructions.
Utiliser uniquement avec l’écran ( n ° 515-005 avec Vignette) ou ( n ° 515-929 Installation avec Louvers) Suivre les instructions d'installation.
Содержание P36E-LP10
Страница 59: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 59 59 parts list ...
Страница 63: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 63 63 notes ...
Страница 68: ......
Страница 69: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 69 69 notes ...
Страница 70: ...70 P36E 10 Zero Clearance Direct Vent Gas Fireplace 70 notes ...
Страница 71: ......