P36E-10 Zero Clearance Direct Vent Gas Fireplace
|
26
installation
• Vent must be supported at offsets.
• Firestops are required at each floor level and whenever
passing through a wall.
• Maintain clearances to combustibles.
Note: Must use optional rigid pipe adaptor when using
rigid vent systems (Part # 510-994).
RIGID PIPE VENTING ARRANGEMENTS
VERTICAL TERMINATIONS
(Propane & Natural Gas)
The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using two 90
o
elbow, with
Rigid Pipe
vent systems for Propane and Natural Gas.