P121 - P121LC/RC - P131 Zero Clearance Direct Vent Gas Fireplace

Model

P121/P131-NG2

P121/P131-LP2

Fuel Type

Natural Gas

Propane

Minimum Supply Pressure

5” W.C. (1.25 kPa)

12” W.C. (3.00 kPa)

Manifold Pressure - High

3.8” W.C. (0.95 kPa)

11” W.C. (2.74 kPa)

Manifold Pressure - Low

1.1” W.C. (0.27 kPa)

2.9” W.C. (0.72 kPa)

Orifi ce Size

#31 DMS

#50 DMS

Minimum Input 

20,500 BTU/h (6.01 kW)

20,600 BTU/h (6.04 kW)

Maximum Input

40,000 BTU/h (11.72 kW)

39,000 BTU/h (11.43 kW)

Vent Sizing

4” Inner / 6-5/8” Outer

4” Inner / 6-5/8” Outer

P

Gas Line

Inlet

Electrical

Inlet

BACK

N

O

M

A

D

C

G

E

B

F

P121 See Thru

P131 Pier

P121RC Right Corner

P121LC Left Corner

Unit Dimensions

Description

P121

P121LC/RC

P131

A

Front Face Width

43-1/2” 

(1105mm)

41-1/2” 

(1054mm)

41-1/2” 

(1054mm)

B

Total Firebox Width

46-1/4” 

(1175mm)

44-1/2” 

(1130mm)

44-1/2” 

(1130mm)

C

Front Face Height

36” (914mm)

36” (914mm)

36” (914mm)

D

Height w/ Standoff

42” (1067mm)

42” (1067mm)

42” (1067mm)

E

Unit Depth

25” (635mm)

26-13/16” 

(681mm)

25” (635mm)

F

Top Offset Depth

21-1/8” 

(537mm)

21-1/8” 

(537mm)

21-1/8” 

(537mm)

G

Inset to Standoff

4-3/4” 

(121mm)

4-3/4” 

(121mm)

3” (76mm)

H

I

J

K

Combustible

Material

3”

Extension

Trim

Non-Combustible

Material *

Top of

Unit

8”

Greyed out framing will not apply to all units.

Please refer to the manual.

L

Framing  Dimensions Description

P121

P121LC/RC

P131

H

Framing Width

46-3/4” 

(1187mm) 

45” 

(1143mm)

**

45” 

(1143mm)

**

I

**

Framing Height 

**

42-1/2” 

(1080mm)

42-1/2” 

(1080mm)

42-1/2” 

(1080mm)

J

**

Framing Depth

**

25” (635mm)

**

26-13/16” 

(681mm)

25” (635mm)

**

K

Vent Centerline Height

42-13/16” (1072mm)

L

Framed Chase Ceiling

48-1/4” (1226mm)

M

Electrical Inlet Height

2” (51mm)

2” (51mm)

2” (51mm)

N

Electrical Inlet Inset

11-3/8” 

(289mm)

13-5/16” 

(338mm)

11-3/8” 

(289mm)

O

Gas Connection Height

1-11/16” 

(43mm)

1-11/16” 

(43mm)

1-5/8” (41mm)

P

Gas Connection Inset

11-1/2” 

(292mm)

11-1/2” 

(292mm)

11-1/2” 

(292mm)

**

 Refer to the manual for variations effected by fi nishing material 

thickness.

P121-P131 Gas Fireplace

If the provided 3” extension trim is not installed the P121(LC/RC)/
P131 must be installed with non-combustible facing up to 8” above 
the fi replace.  Otherwise combustible facing may be used above the 
extension trim.

Approved Venting Systems

Flex Vent Systems:

FPI AstroCap™ Flex Vent

Rigid Pipe Vent Systems:

Simpson Dura-Vent® Direct Vent GS
American Metal Products Ameri Vent  
Security Secure Vent® 
Selkirk Direct-Temp.

Please refer to Page 11 (Exterior Vent Terminations) 

for additional guidelines on vent locations.

69

June 2007 Regency Product Specifi cations Book

Gas Fireplaces

Gas Fir

eplaces

Содержание P121-LP2

Страница 1: ...erial Top of Unit 8 Greyed out framing will not apply to all units Please refer to the manual L Framing Dimensions Description P121 P121LC RC P131 H Framing Width 46 3 4 1187mm 45 1143mm 45 1143mm I Framing Height 42 1 2 1080mm 42 1 2 1080mm 42 1 2 1080mm J Framing Depth 25 635mm 26 13 16 681mm 25 635mm K Vent Centerline Height 42 13 16 1072mm L Framed Chase Ceiling 48 1 4 1226mm M Electrical Inle...

Страница 2: ...clearances are critical Combustible mantel clearances from top of the louvers are shown in the diagram below Mantel may be installed anywhere in the shaded area or higher Note If desired a non combustible mantel may be installed at a lower height Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour Note Ifthefireplaceisinstalled without the 3 ...

Страница 3: ...orizontal sections must be supported every 3 feet P121 P131 Gas Fireplace Snorkel Terminations Snorkel Terminations For installations requiring a vertical rise on the exterior of the building 14 inch and 36 inch tall Snorkel Terminations and the Riser Vent are available Follow the same installation procedures as used for standard Horizontal Termination NEVER install the snorkel upside down Below G...

Страница 4: ...feet Total horizontal sections must not exceed 8 feet Minimum of 1 foot between 90 elbows is required A 1 Min 2 Max B 2 Min 4 Max C 3 Min 6 Max D 4 Min 8 Max IMPORTANT When installing this unit vertically the 45 elbow when installed in conjunction with the Rigid Pipe Adapter will protrude past the unit 1 38mm when measured from the rear standoffs Note A 1 32mm clearance from the elbow must also be...

Страница 5: ...Min B 4 Max 2 Min C 6 Max 3 Min D 8 Max 4 Min Vertical Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V V1 H H1 Maximum total pipe length of all sections must not exceed 37 feet Total horizontal sections must not exceed 12 feet Minimum of 1 foot between 90 elbows is required A 2 Min 3 Max B 3 Min 6 Max C 4 Min 9 Max D 5 Min 12 Max Vertical Venting with Th...

Страница 6: ...orizontal Terminations This diagram shows allowable venting configurations using one 45 Note Must use optional flue adapter Part 770 994 when using Rigid Pipe Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the termination is lower than the specified mi...

Страница 7: ... 3 Max 2 Min 6 Max C 5 Max 3 Min 9 Max D 8 Max 5 Min 12 Max Horizontal Venting with Three 3 90 Elbows Initial vertical section Two 45 elbows One 90 elbow Option V V1 H H1 Maximum total pipe length of all sections must not exceed 37 feet Total horizontal sections must not exceed 12 feet Minimum of 1 foot between 90 elbows is required A 2 Min 3 Max B 3 Min 6 Max C 4 Min 9 Max D 5 Min 12 Max Horizont...

Отзывы: