background image

Unit requires 120V to 

operate.

 See “Wiring Diagram” 

section in manual for more 

details. Receptacle is included 

with manual package.

Tested by:

FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

918-610c

MODELS:   L900-NG Natural Gas   L900-LP Propane

LIBERTY

     

L900 Gas Fireplace

FOR YOUR SAFETY
What to do if you smell gas:

 

Do not try to light any appliance

 

Do not touch any electrical switch: 
do not use any phone in your 
building.

 

Immediately call your gas supplier 
from a neighbour's phone. Follow 
the gas supplier's instructions.

 

If you cannot reach your gas 
supplier, call the fi re department.

WARNING:  
If the information in these instructions are not followed exactly, 
a fi re or explosion may result causing property damage, 
personal injury or loss of life. 

FOR YOUR SAFETY
Do not store or use gasoline or other fl ammable vapors and 
liquids in the vicinity of this or any other appliance.

Installation and service must be performed by a qualifi ed 
installer, service agency or the gas supplier.

11/14/07

Owners & 

Installation Manual

Installer

: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

www.regency-fi re.com

TM

Содержание LIBERTY L900-LP

Страница 1: ...hone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department WARNING Iftheinformationintheseinstructionsarenotfollowedexactly a fire or explosion may result causing property damage personal injury or loss of life FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance Installation a...

Страница 2: ...ndard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile Home Standard in Canada This appliance installation must comply with the manufacturer s installation instructions and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223...

Страница 3: ...s 22 Allowable Vertical Terminations 22 Unit Installation with Horizontal Termination 23 Unit Installation with Vertical Termination 24 Horizontal Termination with Flex Vent System 25 High Elevation 26 Gas Line Installation 26 Pilot Adjustment 26 Gas Pipe Pressure Testing 26 SIT 825 Valve Description 26 Back Up Battery Installation within Power Module 27 Conversion Kit 546 969 from NG to LP 28 Bri...

Страница 4: ...rd Title 24 CFR Part 3280 or the current Standard for Fire Safety Criteria for Manufactured Home Installation Sites and CommunitiesANSI NFPA501A and with CAN CSAZ240 MH Mobile Home Standard in Canada This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket permanently located manufactured mobile home where not prohibited by local code...

Страница 5: ...de directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon ...

Страница 6: ...Regency L900 Direct Vent Gas Fireplace 6 INSTALLATION UNIT DIMENSIONS ...

Страница 7: ...and ANSI Standards to make you aware of the following YOUNG CHILDREN SHOULD BE CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE CLOTHING OR OTHER FLAMMABLE MATERIALSHOULDNOTBEPLACED ON OR NEAR THE APPLIANCE INSTALLATION AND REPAIR SHOULD BE DONE BY AN AUTHORIZED SERVICE PERSON THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A PROFESSIONAL SERVICE PERSON MO...

Страница 8: ...g this appliance Have an authorized inspector dealer or installer review your plans before installation Note For vent terminations refer to ExteriorVent TerminationLocations section HEATWAVE DUCT KIT The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warmairfromthefireplacetoremotelocationsin the same room or other rooms in your home Up to two kits may be installed...

Страница 9: ... 3 76mm Side 2 51mm Bottom 2 51 mm Vertical Vent Clearances to Combustibles All Sides 2 51mm Alcove Clearances Min Depth 36 914mm Min Width 84 2134mm Min Height 84 2134mm Alcove side wall must have a minimum of 16 406mm clearance on one side Caution Requirements The top back and sides of the fireplace are defined by standoffs The metal ends of the standoff may NOT be recessed into combustible constr...

Страница 10: ...l clearances from top of front facing are shown in the diagram below Note A non combustible mantel may be installed at a lower height if the framing is made of metal studs covered with a non combustible board Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram ...

Страница 11: ... itself 3 The unit does not have to be completely enclosed in a chase You must maintain clearances from the vent to combustible materials See Clearances section Combustible materials can be laid against the side and back standoffs and the stove base FRAMING FINISHING 26 1 2 673mm 6 152mm 5 127mm 2 51mm 76 1930mm 12 1 4 311mm 17 1 2 445mm Header On Edge Drywall Non Combustible Material 50 3 4 1289m...

Страница 12: ...off securely to the top with 2 screws per standoff on opposite corners Side Nailing Strips shown folded out FINISHING TEMPLATE In order to maintain a clean face the L900 allows for a 1 8 in overlap of finishing material such as rock or tile on both the left and right hand sides of the unit top and bottom sides do not allow for an overlap this overlap must not be exceeded or the glass door will no l...

Страница 13: ...losing warm room air up the chimney Note These flue pipes must not be connected to any other appliance The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Eachdirectventgasappliancemustuseit sown separate vent system Common vent systems are prohibited Vent Restrictor Plate...

Страница 14: ...tor vent outlet min 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet min 72 1 8m 3 91cm above if within 10 3m horizontally M Clearance above paved sidewalk or a paved driveway located on public property min 84 2 1m N Clearance under veranda porch deck or balcony min 33 8...

Страница 15: ...tion Cap AstroCap XL TM Part 946 623 P Vent Guard if required Part 946 506 P Wall Thimble Mandatory in all Horizontal Terminations Vinyl Siding Standoff Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from FPI may be used for Flex installations 3 Horizontal vent must be supported every 3 feet 4 Awallthimbleismandatoryforallhorizontalterminations d...

Страница 16: ...Length Vertical Terminal Storm Collar Flashing Ceiling Firestop 24 Pipe Length Adj Pipe Length 11 14 5 8 90 Elbow o AstroCap XL Termination Cap Part 946 623 P Wall Thimble Mandatory in all Horizontal Terminations Vinyl Siding Standoff Optional Vent Guard if required Part 946 506 P When using Rigid Vent other than Simpson Dura Vent 3 screws must be used to secure rigid pipe to adaptor The FPI Astro...

Страница 17: ... 17 24 Galvanized Disc See 58DV 16A Disc See 58DV 16A N A N A Adjustable Length 17 24 Black Disc See 58DV 16AB Disc See 58DV 16AB N A N A Extension Pipe 8 1 2 Galvanized 58DVA 08A N A from FPI 58DVA 08A N A from FPI N A N A Extension Pipe 8 1 2 Black 58DVA 08AB 58DVA 08AB N A N A Extension Pipe 16 Galvanized 58DVA 16A N A from FPI 58DVA 16A N A from FPI N A N A Extension Pipe 16 Black 58DVA 16AB 5...

Страница 18: ... Fab Sure Seal Round Support Radiation Sheild N A N A N A N A Flat Flashing N A N A N A N A Attic Insulation Shield 12 58DVA IS N A from FPI 58DVA IS N A from FPI N A N A Basic Horizontal Termination Kit A N A N A 5DT HKA N A Horizontal Termination Kit B 58DVA KHA N A 5DT HKB N A Vertical Termination Kit 58DVA VCH 1291 5DT VKC N A High Wind Vertical Cap N A N A N A N A High Wind Horizontal Cap DIS...

Страница 19: ...OR SETTING Vent restrictor at 0 factory set no adjustment required unless otherwise indicated Refer to the Vent Restrictor Position section for details on how to change the vent restrictor to Set 1 Set 2 or Set 3 if required A vent guard is required when the AstroCap is installed above grade at 7 feet or lower A vent guard may also be required in other installations as per local codes refer to Ext...

Страница 20: ...orizontal One 90o elbow Two 45o elbows Option V H V V1 H H1 A 2 Min 1 Max 5 Min 2 Max B 3 Min 1 Max 6 Min 3 Max C 4 Min 3 Max 8 Min 6 Max D 5 Min 4 Max 10 Min 8 Max E 5 Min 4 Max 11 Min 10 Max With these options max total pipe length is 30 feet with min of 11 feet total vertical and max 10 feet total horizontal Please note min 1 foot between 90o Please note minimum 1 foot between 90o elbows is req...

Страница 21: ... C 4 Min 5 Max 8 Min D 5 Min 6 Max 9 Min E 6 Min 8 Max 10 Min One 90o elbow Two 45o elbows With these options max total pipe length is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required VENT RESTRICTOR SETTING Vent restrictor at 0 factory set no adjustment required INSTALLATION ...

Страница 22: ...s Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles as listed in the Clearances section Refer to Vent Restrictor Position section for details on how to change the vent restrictor to Set 1 Set 2 or Set 3 if required Note Must use optional flue adapter when using Rigid Pipe Part 770 994 INSTALLATION Maximum 40 ft 12 2m Minimum 8 6 2 6m M...

Страница 23: ...with special twist lock connections to connect the venting system to the appliance flue outlet A twist lock appliance adaptor is required 3 In conjunction with the Simpson Dura Vent Direct Vent GS system Install the adaptor after the unit is set in its desired location Put a bead of high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the inner collar Slip th...

Страница 24: ...heceiling to the position of the appliance flue exit andmarkthelocation where the vent will penetratetheceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previously drilled in the ceiling and mark the spot where the ventwillpenetratetheroof Determineifceiling joists roof rafters or other framing will obstruct the venting system You may wish to relocate theappli...

Страница 25: ... where the use of a firestop or wall thimble reduces the required clearance to 1 1 2 38mm Werecommendframinga11 279mm x 11 279mm inside dimensions hole to give structural rigidity for mounting the termination 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termin...

Страница 26: ...leaks with a soap and water solution or gas leak detector Do not use open flame for leak testing HIGH ELEVATION This unit is approved in Canada for altitude 0 to 4500 ft CAN1 2 17 M91 GAS LINE INSTALLATION Since some municipalities have additional local codes it is always best to consult with your local authorities and the CAN CGA B149 installation code For USA installations follow local codes and ...

Страница 27: ...2 screws one on each side 8 Install the 9V battery and the AA battery 2 Loosen the 2 screws that hold the left side heat shield in place BACK UP BATTERY INSTALLATION within Power Module Power Module Power Module a Release the 2 door latches on the left and right side at the top of the firebox b Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up ...

Страница 28: ... top of the firebox b Swing the door out from the top and release the hinges on the left and right side of the door by lifting them up Latch c Placethedooronasoftsurfacetoprevent scratching Hinge Door Latch Location 2 Remove the grate by undoing the 2 screws on the right and left side 3 Remove the front burner by removing the screw Grate Front Burner Front Burner Removed THIS CONVERSION MUST BE DO...

Страница 29: ...ifice 50 See image below Use another wrench to hold onto the elbow behind the orifice Front Burner Orifice Rear Burner Orifice 8 Remove the pilot shield by removing the 2 screws 9 Removetheclipfromthepilotheadassembly using a flat head screw driver 10 Remove the NG pilot orifice with the Allen Key and replace with LP pilot orifice 11 Re install the pilot head and pilot shield Pilot Shield Clip 16 Us...

Страница 30: ...el by undoing the 8 screws 23 Locate the control box shown below and remove the J9 jumper using needle nose pliers 24 Re install the left side panel 25 Re install the rear log support bracket 26 Adjust the burner aeration settings to the LP settings and install the burners Front Burner 1 4 Rear Burner 3 8 27 Re install the grate 28 Re install the glass door 29 Re install the right heat shield 30 C...

Страница 31: ...h c Placethedooronasoftsurfacetoprevent scratching Hinge Door Latch Location Heat Shield 4 Loosen the 2 screws that hold the left side heat shield in place 5 Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield Bracket Heat Shield 6 Unplug the power source 7 Remove the log set if installed 8 Remove interior...

Страница 32: ...d the valve tray to the firebox and slightly pull out the valve tray 20 Disconnect the black and red wires from the solenoid valve 22 Completely pull out the valve tray Wires Valve Tray Slightly Removed Modulating Coil Heat Shield Valve Tray 17 Disconnect the 2 connectors from the modulating coil 18 Remove the DC Sparker wires 1 wire for the ignitor and 2 wires to the module box 23 Replace the fro...

Страница 33: ...ctions to the valve and solenoid valve 35 Cut the cable tie that holds the wires connected to the Control Module and pull out Note An extra cable tie is included with the LP Kit for re installation Cable Tie Control Module 36 Remove the J9 jumper using needle nose pliers 37 Re install the control module 38 Re install the base brick panel 39 Re install the rear log support bracket 40 Plug in the po...

Страница 34: ...elease the hinges on the left and right side of the door by lifting them up Latch c Place the door on a soft surface to prevent scratching 2 Unwrap the brick panels from the protective wrapping Note The logs must not be in the unit 3 Remove the 2 brick panel clips on the inside left and right side of the firebox by removing the screw Hinge Door Latch Location Screw Brick Panel Clip 4 Place the 2 s...

Страница 35: ... slot of the exterior base brick panel The top of the brick panel is held in place by a magnet that sits against the bracket as shown in the image below Repeat for left side exterior brick panel Outerbox of Firebox Tab Bracket Exterior Brick Panel Installation L e f t Side Brick Panel Base Brick Panel Slot Top Brick Panel Top Brick Panel Right Side Brick Panel Brick Panel Clip 6 Place the top bric...

Страница 36: ... 902 179 Vermiculite 1 Carefully remove the logs from the box and unwrap them The logs are fragile handle with care do not force into position 2 Place log 03 41 on the rear log support pins The 03 reference numbers i e 03 41 are molded into the rear of each log 3 Place log 03 42 on the front left side of the burner Place the right end of the log into the pin and rest the notch on the left end of t...

Страница 37: ...Embers on inside of grate 6 Line up the two holes on the underside of log 03 44 with the pins on logs 03 41 and 03 42 and fit in place 03 44 03 41 03 42 7 Line up the two holes on the underside of log 03 45 with the pins on logs 03 41 and 03 43 and fit in place 03 45 03 41 03 43 5 Place the left end of log 03 43 into the pin while fitting the notch onto the burner tube Slide the right end of the l...

Страница 38: ...l gas supply or altitude Open the air shutter for a blue flame or close for a more yellow flame In order to adjust the aeration the logs grate and burners will need to be removed to be able to access the shutters Minimum Air Shutter Opening NG Front Burner 1 4 Rear Burner 1 2 LP Front Burner 1 4 Rear Burner 3 8 CAUTION Labelallwirespriortodisconnection when servicing controls Wiring errors can cause...

Страница 39: ...g NOTE The main burner will always start on HIGH and resume it s last setting after 20 seconds of operation NOTE Whentheglassiscoldandtheappliance is lit it may cause condensation and fog the glass This condensation is normal and will disappear in a few minutes as the glass heats up DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT FIRST FIRE DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT...

Страница 40: ...ake a very slight whisper sound Gas Control Valve As the gas control valve turns ON and OFF a dull clicking sound may be audible this is normal operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process OPERATION DURING POWER O...

Страница 41: ... turn the gas control knob Never use tools If the knob will not push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas ...

Страница 42: ...caps pipe and fittings It may be caused by having excessive lateral runs too many elbows and exterior portions of the system being exposed to cold weather 4 Inspect joints to verify that no pipe sections or fittings have been disturbed and consequently loosened Also check mechanical supports such as Wall Straps or plumbers tape for rigidity LOG REPLACEMENT The unit should never be used with broken l...

Страница 43: ... on each side 9 Replace the 9V battery and the AA battery 3 Loosen the 2 screws that hold the left side heat shield in place BACK UP BATTERY REPLACEMENT within Power Module Power Module Power Module a Release the 2 door latches on the left and right side at the top of the firebox b Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up Hinge Door La...

Страница 44: ...Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield 3 Loosen the 2 screws that hold the left side heat shield in place Power Module Power Module with Cover Removed Circuit Board Removed POWER MODULE REPLACEMENT 10 Replace the circuit board 11 Reverse steps to re install 5 Unplug the power source Heat Shiel...

Страница 45: ...shield in place 4 Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield Control Module 9 Replace the control module 10 Reverse steps to re install CONTROL MODULE REPLACEMENT 5 Unplug the power source a Release the 2 door latches on the left and right side at the top of the firebox b Swingthedooroutfromthetopa...

Страница 46: ...exterior brick panels 2 Remove the glass door Battery Cover DC SPARKER REPLACEMENT a Release the 2 door latches on the left and right side at the top of the firebox b Swingthedooroutfromthetopandrelease the hinges on the left and right side of the door by lifting them up Hinge Door Latch Latch Location Heat Shield Bracket Heat Shield 11 Replace the DC sparker 12 Reverse steps to re install 6 Loosen...

Страница 47: ...d 3 Loosen the 2 screws that hold the left side heat shield in place 4 Lift up and pull out the heat shield slightly to clear the screwheads and then hang it on the top bracket located directly above the heat shield Bracket Heat Shield 5 Unplug the power source 6 Remove the log set 7 Remove the interior brick panels 8 Remove the grate by undoing the 2 screws on the right and left side 9 Remove the...

Страница 48: ...tom Brick Panel 13 Loosen the 2 screws that hold the right side heat shield 14 Lift up and pull out the heat shield slightly to clear the head screws and then hang it on the top bracket located directly above the heat shield Bracket Heat Shield 15 Disconnect the inlet gas line from the valve 16 Disconnect the 2 connectors from the modulating coil 17 Disconnect the 2 red wires and 1 black wire from...

Страница 49: ...or Frame Assembly with Glass 940 354 P Glass 13 546 013 One Piece Faceplate 15 521 021F Control Arm 16 521 019 Bracket Control Arm 17 546 070 Heat Shield Valve 18 521 024 Gas Line Screen Plate 20 546 901 Brick Panel Set Standard Brown 546 902 Brick Panel Set Standard Red Left Side Panel Interior Top Panel Interior Back Panel Interior Right Side Panel Interior Right Side Panel Exterior Base Panel E...

Страница 50: ...Regency L900 Direct Vent Gas Fireplace 50 PARTS LIST PARTS LIST ...

Страница 51: ...840470 Gasket Pilot Assembly 46 521 007 Valve Tray 47 546 025 Valve Bracket 48 910 460 Valve NG 825 SIT Electric 910 461 Valve LP 825 SIT Electric 546 574 P Valve Assembly NG 546 576 P Valve Assembly LP 910 008 Pilot Assembly NG 910 009 Pilot Assembly LP 904 617 NG Orifice 30 904 622 NG Orifice 47 904 241 LP Orifice 56 904 641 LP Orifice 50 PARTS LIST Part Description 910 937 Valve Solenoid 910 929 Co...

Страница 52: ...Regency L900 Direct Vent Gas Fireplace 52 NOTES ...

Страница 53: ...Regency L900 Direct Vent Gas Fireplace 53 NOTES ...

Страница 54: ...Regency L900 Direct Vent Gas Fireplace 54 NOTES ...

Страница 55: ...ransportation Prepaid if requested Porcelain Enamel Absolute perfection is either guaranteed nor commercially possible Any chips must be reported and inspected by an authorized dealer within three days of installation Reported damage after this time will be subject to rejection It is the general practice of FPI to charge for larger higher priced replacement parts and issue credit once the replaced...

Страница 56: ...__________________________________________ Printed in Canada Regency Liberty AstroCap HeatWave Heat Release and FireWizard are trademarks of FPI Fireplace Products International Ltd Register your Regency online at http www regency fire com Copyright 2007 FPI Fireplace Products International Ltd All rights reserved FPI fireplaces are designed with reliability and simplicity in mind In addition our in...