To the New Owner:

Congratulations! 

You are the owner of a state-of-the-art Gas Fireplace by 

REGENCY

®

. The Gem54 has been 

designed to provide you with all  the warmth and charm of a wood fireplace at the flick of a switch.  

The model Gem54 has been approved by AGA for both safety and efficiency.  As it also bears 

our own mark, it promises to provide you with economy, comfort and security for many trouble 

free years to follow.  Please take a moment now to acquaint yourself with these instructions and 

the many features of your Regency

®

 Fireplace.

Содержание GEM54-LPG

Страница 1: ...l your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department 918 784d Regency Gem54 Gas Fireplace 08 21 15 Owners Installation Manual www regency fire com au Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future referen...

Страница 2: ...the warmth and charm of a wood fireplace at the flick of a switch The model Gem54 has been approved by AGA for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace ...

Страница 3: ...r Gem54 ng 24 Venting Arrangements 25 Allowable Vertical Terminations for Gem54 lpg ULPG 25 Unit Installation with Horizontal Termination 26 Unit Installation with Vertical Termination 27 Unit Installation 28 High Elevation 29 Gas Line Installation 29 Pilot Adjustment 29 Gas Pipe Pressure Testing 29 S I T Valve Description 29 Conversion from NG to LPG 30 Conversion from NG to ULPG 30 Aeration Adju...

Страница 4: ...ize 1 x 32 1 x 51 1 x 52 2 95mm 1 70mm 1 61mm Model Approval No AGA 7493 G Code AS4558 NZ5262 Part 918 785 Rev B Colour Black on Grey Size 100 Sept 4 08 no changes to artwork Apr 30 09 Received certification June 10 13 Revised AGA Dec 24 13 Updated E Aus address and code format Distributed by To be installed by an authorised person in accordance with installation instructions provided with the app...

Страница 5: ...DIMENSIONS 59 1499mm 52 5 8 1337mm 48 1 2 1232mm 20 1 2 521mm 19 3 4 502mm 10 5 8 270mm 1 1 2 38mm 31 5 8 803mm 46 3 8 1178mm 35 1 4 895mm 22 3 8 568mm 17 1 8 435mm 5 11 16 144mm FACEPLATE DOOR FRAME OVERLAY DIMENSIONS UNIT DIMENSIONS ...

Страница 6: ...YAWAYTOAVOIDBURNS OR CLOTHING IGNITION YOUNGCHILDRENSHOULDBECARE FULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE 1 The appliance installation must conform with local codes or in the absence of local codes with the current Installation and Building Codes 2 The appliance when installed must be elec trically grounded in accordance with local codes 3 See general construction and assem...

Страница 7: ...l Mounted ON OFF Switch Use the toggle wall switch supplied with the manual package Use of a decor switch causes higher resistance which is a problem on gas fireplaces 10 Final check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer INSTALLATION CHECKLIST 1 Locate appliance a Room location Refer to ...

Страница 8: ...his fireplace and vent system be installed only in accordance with these instructions F B E D A Installed Close to Floor G 48 1219mm 4 102mm 5 11 16 144mm 28 711mm 20 508mm 22 1 2 52 5 8 60 1 2 1537mm Non combustible Material Non combustible Material Non combustible Material Non combustible Material Metal Stud header Wood Stud Wood Stud Clearance Dimension Measured From A Mantel Height min 20 508m...

Страница 9: ...ible material and drywall 3 Prior to taping and mudding it is highly recommended to prime the facing and edges using a quality primer This will ensure proper adhesion of both the tape and mud The optional board is very porous During dry fit ensue that both surfaces being taped are even 4 Tape the seams using a mesh type tape 5 To seal up seams as normal we recommend using a product called Durabond...

Страница 10: ...2mm Non Combustible Drywall 2 0 12 6 4 8 10 Top of Fireplace Opening 13 330mm 3 89mm Standoff Metal Stud On Edge 0 14 Non combustible Facing To Floor 1 25mm 30 762mm 20 21 28 1 8 724mm 51mm 102mm 152mm 203mm 254mm 305mm 356mm Due to the extreme heat this fireplace emits the mantel clearances are critical Combustible mantel clearances from top of front facing are shown in the diagram on the right N...

Страница 11: ...on Combustible materials can be laid against the side and back standoffs and the stove base 4 If material such as brick stone etc extends past the faceplate depth when finishing around the faceplate the minimum opening dimen sions noted below must be adhered to ensuring for the removal of the faceplate FRAMING FINISHING 1 Frame in the enclosure for the unit with framing material IMPORTANT Header m...

Страница 12: ...1295mm E Corner Wall Length 72 1829mm F Corner Facing Wall Width 101 7 8 2586mm G Vent Centerline Height 44 1118mm H Non combustible facing height 20 508mm I Gas Connection Opening Height 1 1 2 38mm J Gas Connection Height 4 102mm K Gas Connection Inset 7 1 4 184mm L Gas Connection Opening Width 3 1 4 83mm Framing depth measurement is noted with the side nailing strips set as far forward on the fi...

Страница 13: ...The Top Standoff Nailing Strip side nailing strips and standoffs must be correctlypositionedandattachedtotheunitbeforeslidingtheunitintoposition STANDOFF ASSEMBLY The side rear and bottom standoffs are shipped in a flat position and must be folded into shape and attached see diagram 1 1 Remove the standoffs from the unit 2 Take each standoff and bend into the correct shape Bend up at the bend line...

Страница 14: ...e in place 3 Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown 4 Once the vent restrictor plate is in the required position secure with screws VENT RESTRICTOR POSITION Vent Restrictor Settings for Gem54 NG Vent Restrictor Settings for Gem54 LP Gem54 ULPG 108mm 76mm 51mm Vent Restrictor Set 1 Vent Restrictor Set 2 Vent Restrictor Set 3 SET 2 THIS HO...

Страница 15: ...ndow door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation see also Note I Appliances up to 150 MJ h input 500 Appliances over 150 MJ h input 1500 k Vertically below an openable window door or non mechanical air inlet or any other opening into a building with the exception of sub floor ventilation I For mechanical air inlets including spa...

Страница 16: ... Exterior Vent Termination Locations section FPI Direct Vent Flex System Termination Kits include all the parts needed to install the Gem54 using a flexible vent Notes 1 Liner sections should be continuous without any joints or seams 2 Only Flex pipe purchased from FPI may be used for Flex installations 3 Horizontal vent must be supported every 3 feet 0 9m 4 Awallthimbleismandatoryforallhorizontal...

Страница 17: ... mounting surface of termination cap For siding other than vinyl furring strips may be used instead of the vinyl siding standoff to create a level surface to mount the vent terminal The Terminal must not be recessed into siding Measure the wall thickness including furring strips If a Vinyl Siding Standoff is required it must be usedwithvinylsiding measuretooutsidesurface of wall without siding and...

Страница 18: ... N A N A N A Ceiling Support 58DVA DC 5DT CS 5DSP TE 5DE45 Cathedral Support Box 58DVA CS 5DT CSS 5DRS TE 5DE45B Wall Support Band 58DVA WS 5DT WS B 5DWS N A Offset Support 58DVA ES N A from FPI 5DT OS N A N A Wall Thimble Black 58DVA WT 5DT WT 5DWT TE 5DE90 Wall Thimble Support Ceiling Support 58DVA DC N A from FPI N A N A TE 5DE90B Firestop Spacer 58DVA FS 5DT FS 5DFS N A Trim Plate Black 58DAV ...

Страница 19: ...946 606 Starter collar reducer 5 x 8 to 4 x 6 5 8 946 625 Vinyl Siding Standoff AstroCap XL Note When using Metal Fab Sure Seal Rigid Piping please note that the Adaptor 4DDA must be used in conjunction with FPI Rigid Pipe Adaptor 510 994 Offset Pipe Selection Use this table to determine offset pipe lengths Pipe Length L 5 x 8 Venting For specific instructions on venting components visit the manuf...

Страница 20: ... at each floor level and whenever passing through a wall A wall thimble is mandatory for all horizontal terminations due to high temperatures VENT RESTRICTOR SETTING Vent restrictor factory set no adjustment required unless otherwise indicated Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 1 to Set 2 or Set 3 if requir...

Страница 21: ...vel and whenever passing through a wall A wall thimble is mandatory for all horizontal terminations due to high temperatures VENT RESTRICTOR SETTING Vent restrictor factory set no adjustment required unless otherwise indicated Refer to the Vent Restrictor Position section for details on how to change the vent restrictor from the factory setting of Set 1 to Set 3 if required Note Regency Direct Ven...

Страница 22: ...ween 90o elbows is required VENT RESTRICTOR SETTING Vent restrictor factory set at Set 1 no adjustment required One 90o elbow Two 45o elbows Option V H V V1 H H1 With these options max total pipe length is 9m with min of 3 4m total vertical and max 2 7m total horizontal A 6m Min 3m Max 9m Min 6m Max B 6m Min 6m Max 1 5m Min 1 2m Max C 9m Min 6m Max 2 1m Min 1 5m Max D 1 2m Min 9m Max 2 7m Min 1 8m...

Страница 23: ...talpipelength is 9m with min of 2 7m total vertical and max 2 4m total horizontal A 6m Min 6m Max 1 2m Min B 9m Min 1 2m Max 1 8m Min C 1 2m Min 1 5m Max 2 1m Min D 1 5m Min 1 8m Max 2 4m Min E 1 8m Min 2 4m Max 2 7m Min Please note minimum 3m between 90o elbows is required VENT RESTRICTOR SETTING Vent restrictor factory set at Set 1 no adjustment required ...

Страница 24: ... to centerline Minimum length of pipe between elbows 12 305mm Maximum 27 ft 8 2m 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 Vertical Height Feet 32 34 36 38 6 8 Horizontal Feet 2 0 4 10 12 16 18 14 20 Vent Restrictor on Set 2 Vent Restrictor on Set 3 Vent Restrictor on Set 1 factory setting VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS FOR GEM54 NG The shaded area in the diagram shows al...

Страница 25: ...nterline Maximum 27 ft 8 2m 0 2 4 6 40 8 10 12 14 16 18 20 22 24 26 28 30 Vertical Height Feet 32 34 36 38 6 8 Horizontal Feet 2 0 4 10 12 16 18 14 Vent Restrictor on Set 3 Vent Restrictor on Set 4 Vent Restrictor on Set 1 factory setting Minimum length of pipe between elbows 12 305mm VENTING ARRANGEMENTS ALLOWABLE VERTICAL TERMINATIONS FOR GEM54 LPG ULPG The shaded area in the diagram shows all a...

Страница 26: ...with special twist lock connections to connect the venting system to the appliance flue outlet A twist lock appliance adaptor is required 3 In conjunction with the Simpson Direct Vent Prosystem installtheadaptoraftertheunitis set in its desired location Put a bead of high temperature silicone inside the outer section of the adapter and a bead of Mill Pack on the innercollar Sliptheadapterovertheex...

Страница 27: ...ue exit andmarkthelocation where the vent will penetrate the ceiling Drill a small hole at his point Next drop a plumb bob from the roof to the hole previously drilled in the ceiling and mark the spot where the vent will penetrate the roof Determine if ceiling joists roof rafters or other framing will obstruct the venting system You may wish to relocate the appliance or to offset as shown in Diagr...

Страница 28: ...279mm x 11 279mm inside dimensions hole to give structural rigidity for mounting the termination 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit Locate the centerline of the termination and mark wall accordingly Cut an 11 279mm hole in the wall inside dimension Note If installing termination on a siding covered wall a vinyl siding standoff or vinyl furrin...

Страница 29: ...at gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante valve should be supplied in or near the unit or as per local codes for ease of servicing this appliance Gem54 NG SYSTEM DATA Min Supply Pressure 1 13 kpa Low Setting Man Pressure 0 4kpa Max Manifold Pressure 0 87 kpa Injector Siz...

Страница 30: ...ntains one ULPG Conversion Kit 476 967 ULPG Conversion Kit Contains Qty Part Description 1 904 390 Burner Orifice 52 1 918 272 Decal Converted to ULPG 1 918 273 Red ULPG label 1 904 529 5 32 Allen Key 1 910 037 LPG Injector Pilot Orifice 1 918 798 Instruction Sheet 1 Warning Turn off the unit by way of the wall switch or remote Allow unit to cool at least 10 min prior to removing the faceplate 2 S...

Страница 31: ...nders on burner tray located behind the burner on either side of the pilot assembly 8 Lift out the 2 burner tray extenders Burner tray extenders Burner tray 14 Remove burner orifice with a 1 2 wrench and discard Use another wrench to hold on to the elbow below the orifice see below Pilot Cap Pilot Orifice 12 Pull off the pilot cap to expose the pilot orifice see below 13 Unscrew the pilot orifice ...

Страница 32: ...se until snug do not overtighten 21 Verify that if the conversion is from NG to LPG the screw must be re assembled with the red o ring visible Fig 5 22 Re assemble the black protection cap Fig 6 WARNING Also check that the pilot and main burner injectors are appropriate for the gas type Fig 1 Fig 2 Fig 3 Fig 4 LPG Configuration Red o ring visible Fig 5 Fig 6 23 Attach the label This unit has been ...

Страница 33: ...ltitude Open the air shutter for a blue flame or close for a more yellow flame Minimum Air Shutter Opening NG 13mm LP Full open 22 mm ULPG Full open 22mm CAUTION Label all wires prior to disconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges CAUTION Carbonwillbeproducedifair...

Страница 34: ...ot be considered a defect Black Enamel panels will discolor a little during normal operation This is normal and should not be considered a defect All hand and finger marks MUST be cleaned off with a soft cloth and a stainless steel cleaner Most stainless steel cleaners leave a film residue on the surface of the panels Use an ammonia based cleaner ie glass cleaner to remove this film before applyin...

Страница 35: ...o removing faceplate Glass Crystals shown on Burner OPTIONAL PEBBLE INSTALLATION FOR FIREBOX BASE There is an optional pebble package to choose from 1 Natural River Pebbles Spread the pebbles evenly on the exposed base of the firebox Pebbles are NOT to be placed anywhere on the burner or over top of the Cobalt Blue Glass Crystals or optional Ceramic Spa Stones Warning Turn off the unit by way of t...

Страница 36: ...llowing are recommended settings for NG and LP units when using the log set NG 1 2 LP Full Open 2 Attach the 12 pin clips to the bottom cover not the burner in the exact locations indicated by an X as shown in Diagram 2 below Note Front and back measurements originate from the centre line of burner Side measurements originate from front edge of the bottom cover see Diagram 3 Note Units may have di...

Страница 37: ...ystal installation section in this manual Pin clips installed dots indicate dimple locations Actual dimples pin clips are black not white as shown Diagram 6 Diagram 8 Diagram 7 6 If installing optional pebbles install pebbles before log installation 5 Place platinum embers on glass crystals as shown in diagram 7 ...

Страница 38: ... 10 9 Install the following a Glass door b Faceplate and door frame Refer to these sections in the HZ54 manual for detailed instructions Diagram 9 Diagram 10 Diagram 11 Log Set Installed shown with optional pebbles 7 Place logs A B on the burner rest logs on the pin clips as shown in diagram 9 Note Logs should be oriented exactly as shown in diagram 9 A B B A C D D C ...

Страница 39: ...is will keep the Faceplate in position after it has been installed Before you start Stainless must be inspected for scratches and dimples prior to installation All claims to be recorded at this time Claims for damage after installation will not receive consideration To protect the finish during installation and handling cotton gloves MUST be worn at all times while handling the panels even when re...

Страница 40: ... to be installed once the top fascia is in place 2 Install the fascia to the unit by hooking the left and right side mounting brackets into the mounting slots at the side of the firebox as shown below It is recommended that you use the first mounting slot the one closest to the door frame overlay out of the 5 so that the faceplate and door frame overlay are flush with one another See diagram below...

Страница 41: ...ned up and flush with the top fascia Completed Faceplate Door Frame Overlay Installation IMPORTANT NOTE To ensure the gap between the door frame and the faceplate are equal from side to side you may need to slide the faceplate slightly to the left or right accordingly Also if necessary the faceplate may be adjusted up and down by loosening the top screw as shown in the diagram below and sliding th...

Страница 42: ...ficult to remove Use a non abrasive cleanerandDONOTATTEMPTTOCLEAN THE GLASS WHILE IT IS HOT TheFIRSTFIREinyourheaterispartofthepaint curing process To ensure the paint is properly cured it is recommendedyou burnyourfireplace for at least four 4 hours the first time When first operated the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from ma...

Страница 43: ...Regency Gemfire Gas Fireplace 43 43 INSTALLATION OPERATING INSTRUCTIONS COPY OF LIGHTING PLATE INSTRUCTIONS OFF a ...

Страница 44: ... panel cover located on the left hand side floor of the firebox Fan Access Panel 6 After extenders have been removed Remove the 2 screws that secure the burner tray at the base of the firebox 7 Slide the burner to the left and lift it out Location of screws securing burner 4 Loosen 6 screws that secure the burner extenders on burner tray located behind the burner on either side of the pilot assemb...

Страница 45: ...3 to the right 12 Remove from unit bracket and attached 6 section of 3 duct from elbow at left side and set aside 13 Remove ground wire 16 Remove fan assembly by sliding to the left and lifting out through the fan access panel This will disconnect right side duct from fan assembly 15 Carefully disconnect spade connectors 17 Reverse steps when service is completed Once re installed make sure 3 duct...

Страница 46: ...en servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for yourprotectionagainstshockhazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug Noelectricalpowersupplyisrequiredforthegas c...

Страница 47: ...Cap and shine a flashlight down the Vent Remove any bird nests or other foreign material 3 Check for evidences of excessive condensation suchaswaterdropletsforming in the inner liner and subsequently dripping outthejoints Continuouscondensationcan cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs toomanyelbows andexteriorportions ofthesystembeingexposedtoc...

Страница 48: ...low it to cool down to room temperature prior to handling 2 Turn off the gas supply to the unit 3 Remove the faceplate by lifting it up off the hinges on the sides of the firebox 4 Remove the door frame overlay by swinging out 45o from the bottom and lift up and out 5 Remove the glass door a Remove the 3 screws shown below at the bottom of the glass door b Swing the door out 45o from the bottom an...

Страница 49: ...lift up and out 3 Disconnect the spark electrode wire from the DC spark box shown in the image below 4 RemovethebatterycoverfromtheDCSpark Box 4 Remove the DC spark box bracket assembly by lifting the bracket tab out from the firebox DC Spark Box Bracket Assembly partially removed Generator Wires 5 Disconnect the 2 DC spark generator wires from the DC Spark box located just behind the bracket tab ...

Страница 50: ...the bottom and lift up and out 5 Remove the glass door a Remove the 3 screws shown below at the bottom of the glass door b Swing the door out 45o from the bottom and lift up and out 6 Remove the burner tray by undoing the 2 screws in between the bot tom cover and burner on the firebox Carefully lift the burner up and out ensuring not to spill the glass crystals Aerial View of the inside of the uni...

Страница 51: ...screws 12 Slightly lift out valve tray 13 Disconnect the inlet gas line 14 Replace valve and reverse steps 7 Remove bottom cover by undoing 3 screws securing it to the firebox base lift up and out Aerial View of the inside of the unit shown 9 Disconnect the DC Sparker leads at the valve 10 Unplug the Ignitor wire from the DC Sparker DC Sparker Lead Ignitor Wire ...

Страница 52: ...ilot Assembly LP 8 904 688 Orifice 32 904 645 Orifice 51 910 096 Pilot Hood 3 way 910 036 Pilot Orifice NG 910 037 Pilot Orifice LP 910 341 Thermopile 910 386 Thermocouple 910 007 Electrode 910 432 Pilot Tube 9 476 101 Burner Extenders 904 658 Inlet Gas Flex Line SS 370 055 Flue Collar Gasket 476 023 Plate Relief Gasket 476 055 Valve Tray Gasket 521 035 Inner Flue Collar Gasket 940 359 P Flush Gla...

Страница 53: ... Reflective Stainless Steel Panels 31 476 944 Faceplate Door Frame Overlay Black 476 947 Faceplate Door Frame Overlay Stainless Steel 946 671 Cobalt Blue Glass Crystals 946 672 Natural River Pebbles 476 540 Door frame w Glass 32 476 532 Screen Assembly ACCESSORIES 30 32 31 ...

Страница 54: ...tallations must be performed by a qualified gas fitter and installed according to all applicable local and national codes Also all service work must be carried out by a qualified gas service person provided by the selling dealer It is the responsibility of the installer to ensure that the appliance is firing as per rating plate Any part or parts of this unit which in our judgement show evidence of...

Страница 55: ...ldings 28 30 Division St 1 3 Conquest Way 17 Mainstreet Place Welshpool WA 6106 Hallam VIC 3803 Te Rapa Ha 3200 08 9350 2200 03 9799 7277 07 849 7535 NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION OR GAS PRESSURE SETTINGS ARE NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...

Страница 56: ...______________________________ Date Installed _______________________________________________________ Serial No ___________________________________________________________ Register your Regency warranty online www regency fire com au Reasons to register your product online today View and modify a list of all your registered products Request automatic email notification of new product updates Stay ...