Regency FG38 FireGenie Freestanding Gas Stove
9
INSTALLATION
AERATION
ADJUSTMENT
The burner aeration is factory set but may need
adjusting due to either the local gas supply or
altitude.
FG38 with 38 mj NG
FG38 with 31 mj LPG
FG38-NG
15 mm Fully Open
FG38-LPG
6.4 mm open
Caution: Carbon will be produced if the air
shutter is closed too much.
Note: Any damage due to carboning re-
sulting from improperly setting the
aeration controls is NOT covered
under warranty.
Embers
Embers
The "02" refer numbers (i.e. 02-65) are
molded into the rear of each log.
LOG SET
INSTALLATION
Read the instructions below carefully and
refer to the diagrams. If logs are broken
do not use the unit until they are replaced.
The gas log kit contains the following:
a)
02-65 Rear
Log
b)
02-56 Middle Left Log
c)
02-44 Front Left Log
d)
02-46 Left
Top
Log
e)
02-45 Front Right Log
f)
02-47 Center
Log
g)
02-48 Middle Right Log
h)
Embers
902-151
i)
Lava 902-154
1)
Carefully remove the logs from the box and
unwrap them. The logs are fragile, handle
with care -
do not force into position.
2)
Sprinkle the embers on the left and right
sides of the fi rebox base.
C)02-44
Pins on Rear Log Support
A)02-65
B)02-56
3)
Place Rear Log A)02-65 on the two pins on
the rear log support.
4)
Place the Middle Left Log B)02-56 on the
two pins as shown.
5)
Place Front Left Log C)02-44 onto the 2
front pins as shown.