Regency FG38-LPG Скачать руководство пользователя страница 6

6

Regency FG38 FireGenie Freestanding Gas Stove

INSTALLATION

CLEARANCES  TO 

COMBUSTIBLES

The clearances listed below are MINIMUM 
distances.  Measure the clearance to both the 
appliance and the chimney connector.  

(The far-

thest distance is correct if the two clearances 
do not coincide.) 

For example, if the appliance 

is set as indicated in one of the fi gures but the 
connector is too close, move the stove until the 
correct clearance to the connector is obtained.  

This unit can be installed on a solid combustible 
surface like a wood fl oor. This unit can also be 
installed directly on carpeting  or vinyl when 
the bottom pedestal cover plate (provided with 
unit) is installed.

This appliance may be installed only with the 
clearances as shown in the situations pictured.  
Do not combine clearances from one type of 
installation with another in order to achieve 
closer clearances. 

Use the minimum clearances shown in the 
diagrams below for all installations.

FG38-NG & FG38-LPG

Reference Dimensions

C  Back Wall to Flue Centerline 10-3/4" / 273 

mm

D  Side Wall to Flue Centerline  20-1/2" / 520 

mm

F  Side Wall to Flue Centerline  11" / 280 mm

Clearances

A  Side Wall to Unit 

7-1/2" / 190 mm

B  Back Wall to Unit 

6" / 155 mm

E  Side Wall to Unit 

2" / 50 mm

M i n i m u m   c e i l i n g 
height is 36" / 914 
mm from top of unit.

If further reduced clear-
ances are needed, ob-
tain requirements for 
construction of a pro-
tected wall from your 
local building authori-
ties and their allowable 
reductions of the listed 
clearances.

DRAFT DIVERTER

This heater has a draft diverter built in. It must 
not be altered, obstructed, or blocked in any way, 
and the unit must be installed so that the draft 
diverter is in the same atmospheric pressure 
zone as the combustion air inlet to the burner. 
This heater must be properly connected to a 
fl ueing system. 

WARNING: Operation of this heater when not 
connected to a properly installed and main-
tained fl ueing system  can result in carbon 
monoxide (CO) poisoning and possible death

.

FLUEING

This heater is a fl ued appliance and must be 
connected to a chimney/fl ue in accordance with 
the installation codes.

Note: 

The rear pedestal cover plate must 
always be fi tted for safety. Electrical 
connections inside.

Flueing Requirements 

A100 mm diameter fl ue is required.  For cosmetic 
or aesthetic purposes 6" outer fl ue can be used 
as long as an approved inner fl ue is installed. 
Fasten but do not penetrate the inner sleeve 
ofthe fl ue when tightening the screw.

The minimum fl ue required is 3.3m from fl oor 
level.
 
Follow all fl ueing manufacturer’s requirements 
and local building codes or AS5601-2004.

 

14)

 This unit can be installed on a solid com-

bustible surface like a wood fl oor as well as 
on carpeting.

INSTALLATION 

CHECKLIST

1) 

Check Clearances to Combustibles, page 
6.

2) 

Install fl ueing, page 6.

3)

  Make gas connections, page 7. 

4)

  If necessary, convert NG to LPG on page 

8.

5)

  Test Gas Pressure, page 7.

6)

  Install log set where indicated on page 9.

7)

  Install Front Door, page 11.

8)

 Test 

for 

fl ue spillage (draft test), page 11.

9)

  Install Remote Control, page 12.

10)

 Final check, page 12.

Before leaving this unit with the customer, the 
installer must ensure that the appliance is fi r-
ing correctly and operation fully explained to 
customer.

This includes:

1)

  Clocking the appliance to ensure the correct 

fi ring rate (rate noted on label) after burning 
appliance for 15 minutes.

2)

  If required, adjusting the primary air to ensure 

that the fl ame does not carbon. First allow 
the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that 
causes sooting or carboning or that results in 
damage is not the responsibility of the manu-
facturer.

Содержание FG38-LPG

Страница 1: ...ult an authorized installer service agency or the gas supplier FOR YOUR SAFETY Do not store or use gasoline or other flam mable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorized installer service agency or the gas supplier PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE Owners Installation Manual LISTINGS AND CODE APP...

Страница 2: ...with all the warmth and charm of a woodstove at the flick of a switch The models FG38 NG and FG38 LPG of this series has been approved by AGA for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of you...

Страница 3: ...t Door Installation 11 Test for Flue Spillage 11 Remote Control optional 12 Final Check 12 Wiring Diagram 12 Operating Instructions Operating Instructions 13 Lighting Instructions 13 Resetting the Unit 13 Shutdown Instructions 13 First Fire 13 Fan Operation 13 Flame Height Adjustment 14 Summary of Controls 14 Normal Operating Sounds of Gas Appliances 14 Copy of Lighting Plate Instructions 15 Maint...

Страница 4: ...ERIALS SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION OPERATE WITH PANELS COVERS OR GUARDS REMOVED FROM THIS APPLIANCE ENCLOSE THIS APPLIANCE DO NOT MODIFY THIS APPLIANCE NEAR THIS APPLIANCE DO NOT 908 602a Australia Only Gas Type NG LPG Model Gas Consumption 38 31 Manifold Pressure 87 2 65 Injector Size 1x 1x 52 FG38 NG FG38 LPG mj mj kPa kPa 33 Serial Number 918 245a Model N...

Страница 5: ... TO EXCESSIVELINTFROMCARPETING ETC IT IS IMPERATIVE THAT CONTROL COM PARTMENT BURNERSANDCIRCULATING AIR PASSAGEWAYS OF THE APPLIANCE BE KEPT CLEAN DUE TO HIGH TEMPERA TURES THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES THISAPPLIANCECANONLY BEFLUEDINACCORDANCE WITH AS5601 2004 OR LO CAL CODES FAILURE TO INSTALL THIS APPLIANCE CORRECTLY MAY CAUSE A SERIOUS HOUS...

Страница 6: ...bustion air inlet to the burner This heater must be properly connected to a flueing system WARNING Operationofthisheaterwhennot connected to a properly installed and main tained flueing system can result in carbon monoxide CO poisoningandpossibledeath FLUEING This heater is a flued appliance and must be connected to a chimney flue in accordance with the installation codes Note The rear pedestal co...

Страница 7: ... and or check the pilot outlet 8 5 The pressure check should be carried out with the unit burning and the setting should be within the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Screw should be snug but do not over tighten S I T Valve Description 1 On Off Solenoid Valv...

Страница 8: ...ve the control box cover by undoing the 3 screws Maneuver through antenna Jumper Location Jumper 15 Adjusting the Outlet Pressure All the adjustments must be carried out in the following order Remove the modulator plastic cap A using needle nose pliers Maximum pressure Turn the unit ON to its highest input rating Screw in the nut B to increase the outlet pressure and screw it out to decrease it Us...

Страница 9: ...e instructions below carefully and refer to the diagrams If logs are broken do not use the unit until they are replaced The gas log kit contains the following a 02 65 Rear Log b 02 56 Middle Left Log c 02 44 Front Left Log d 02 46 Left Top Log e 02 45 Front Right Log f 02 47 Center Log g 02 48 Middle Right Log h Embers 902 151 i Lava 902 154 1 Carefully remove the logs from the box and unwrap them...

Страница 10: ...esitation check that area for any blockage of the burner port F 0 2 4 7 E 02 45 A 02 65 G 02 48 D 0 2 4 6 B 02 56 C 02 44 Cutout Pin D 02 46 B 02 56 A 02 65 6 Place the Left Top Log D 02 46 on the pin on Log B 02 56 and on top of the cutout on Log A 02 65 E 02 45 C 02 44 7 Place Front Right Log E 02 45 on the two pins as shown 8 Place the lava rock in the area between the left and right logs leavi...

Страница 11: ...nsmaking sure the two pieces are flush together See diagram 1 3 Close the door The latch plate must be centered around the alignment pin See diagram 2 If the latch plate interferes with the corner of the stove you may want to angle the plate slightly so the door closes easier Diagram 2 Diagram 3 4 The latches should already be at the proper setting If they are too hard or too easy to close you may...

Страница 12: ... convenient location to mount the hand held transmitter protection from extreme heat is very important By usiing the wall mounting plate to house the transmitter the remote can also be used as a wall thermostat FINAL CHECK Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly This includes 1 Clocking the appliance to ensure the cor rect firing ...

Страница 13: ...before another reset is attempted SHUTDOWN INSTRUCTIONS 1 Press the ON OFF switch once 2 The LED will flash 3 Turn off all electric power to the appliance if service is to be performed FIRST FIRE The FIRST FIRE in your heater is part of the paint curing process To ensure that the paint is properly cured it is recommended that you burn your fireplace for at least four 4 hours the first time you use...

Страница 14: ...operation of a gas regulator or valve Unit Body Firebox Different types and thicknesses of steel will expand and contract at different rates resulting in some cracking and ticking sounds will be heard throughout the cycling process OPERATING INSTRUCTIONS WARNING DO NOT SPRAY AEROSOLS IN THE VICINITY OF THIS APPLIANCE WHILE IN OPERATION ADJUSTING FLAME HEIGHT Therearesixflamesettingsthatcanbeadjust...

Страница 15: ...all a qualified service technician to inspect theapplianceandtoreplaceanypartofthecontrolsystem and any gas control which has been under water This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air LIGHTING INSTRUCTIONS TO TURN OFF GAS APPLIANCE This appliance must be installed in accordance with local codes if an...

Страница 16: ... the flameoftheburnerperiodically makingsure the flames are steady not lifting or floating If there is a problem call an authorized service person 4 The appliance and flueing system must be inspected before use and at least annu ally by an authorized field service person to ensure that the flow of combustion and ventilation air is not obstructed During the annual service call the burners should be...

Страница 17: ...ould be plugged directly into a properly grounded three prong receptacle Donotcutorremovethegrounding prong from this plug Installing Glass 1 Install both center and side glass onto aluminium extrusions as per diagram 2 Place glass assembly into door frame 3 Install retainers by placing 1 drop of glue where previously glued and put in place 4 Install side retainers 5 Install door catch plate 6 Ins...

Страница 18: ...soft cloth on thebaseoftheunitsothatwhenthepedestal doorisopenitdoesn tscratchthepaint See diagram below 5 Open the side pedestal door by unscrewing the 2 Philips screws 6 Disconnect the valve wires from the 9 pin connector located on the right side of the connector Valve wires consist of 2 orange 1 yellow and 2 purple colored wires MAINTENANCE 7 At this point you should disconnect the gas at the ...

Страница 19: ...A N A N A N A N A 910 088 Spark Cable N A N A N A N A N A N A N A 910 084 Control Box 910 527 Manual Control Switch N A N A N A N A 910 080 Valve 910 521 Control Box Cable 1 910 522 Control Box Cable 2 910 523 Control Box Cable 3 910 525 Control Box Cable 4 2 N A 2 2 1 4 3 N A 2 910 912 Ignition Module to Valve Cable N A N A N A 910 906 Reset Switch N A N A 910 083 Ignition Module 1 910 922 Igniti...

Страница 20: ...Pedestal Back 19 756 518 Side Panel Door Assy Right Side 20 756 520 Side Panel Door Assy Left Side 21 560 031 Hinge for Side Panel Part Description Part Description 23 904 258 Side Panel Door Magnet 24 948 255 Door Latch c w Hook 25 750 095 Door Hold Down Bracket 30 750 026 Rear Panel 32 730 028 Firebox Baffle 33 560 535 False Top Assembly 34 590 273 Flue Attachment Bracket 35 590 930 Ult 6 Flue C...

Страница 21: ... Orifice LPG at 31 mj 71 752 528 Rear Log Bracket Assy 72 910 082 Ignition Direct Spark Assy NG LPG 75 730 935 Log Set 78 752 550 Burner Assy NG LPG 910 083 Module Sit 230V 910 084 Control Box ECS 910 088 Wire ECS Module Spark Red 910 089 Wire ECS Module Flame Red 910 086 Remote Control ECS optional 92 Rear Log 93 Left Top Log 94 Center Log 95 Middle Right Log 96 Middle Left Log 97 Front Right Log...

Страница 22: ...107 208 111 105 WRAP DOOR DOOR ASSEMBLY 730 933 Black Wrap Door Complete 101 846 570 Door Gasket Kit 105 Ceramic Paper 107 936 243 Glass Gasket 111 Door Frame Fibre Paper 208 940 325 P Wrap Glass Not available as a replacement part Part Description PARTS LIST ...

Страница 23: ...al It is essential that all submitted claims provide all of the necessary information including purchase date serial type of unit and part or parts requested Regency Fireplace Products are designed with reli ability and simplicity in mind In addition our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our door Regency Indus tries Ltd is pleased to extend th...

Страница 24: ...Printed in Canada Copyright 2009 FPI Fireplace Products International Ltd All rights reserved ...

Отзывы: