B36XT Gas Fireplace
Regency Bellavista B36XT Gas Fireplace
Unit Dimensions
Description
B36XT
A
Width (at front including standoffs)
40 - 5/16”
B
Width (at back of unit)
33”
C
Height Front Face
35-1/4”
D
Height (including standoffs)
41 - 5/16”
E
Glass Viewing Area (Height)
21”
F
Glass Viewing Area (Width)
30-3/8”
G
Height from Base of Unit
to Bottom Louver Opening
1”
H
Width Front Face
36”
I
Unit Depth (excluding standoffs)
17-5/16”
J (Rear Vent)
Unit Depth (including rear fl ue)
20-1/4”
J (Top Vent)
Unit Depth (including standoffs)
20-5/16”
K (Top Vent)
Height to Top Vent
35-1/4”
L (Rear Vent)
Height to Rear Vent Centerline
26-1/2”
Model
B36XT-NG
B36XT-LP
Fuel Type
Natural Gas
Propane
Minimum Supply Pressure
5” W.C.
(1.25 kPa)
11” W.C.
(2.74 kPa)
Manifold Pressure - High
3.5” W.C.
(0.87 kPa)
10” W.C.
(2.49 kPa)
Manifold Pressure - Low
1.6” W.C.
(0.40 kPa)
6.4” W.C.
(1.60 kPa)
Orifi ce Size
#35 DMS
#51 DMS
Minimum Input
21,500 BTU/h (6.3 kW)
25,000 BTU/h (7.33 kW)
Maximum Input
31,000 BTU/h (9.09 kW)
31,000 BTU/h (9.09 kW)
Vent Sizing (Rear Vent)
5” Inner / 8” Outer
5” Inner / 8” Outer
Vent Sizing (Top Vent)*
5” Inner / 8” Outer
5” Inner / 8” Outer
*Optional Reducer Available.
See Price Pages & Manual for more details
Approved Venting Systems
Flex Vent Systems:
FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems:
Simpson Direct Vent Pro®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit.
Some specifi cations may change without notice.
You must use the actual manual for exact installation specifi cations.
Framing
Dimensions
Description
B36XT
M
Framing Width
40-5/8”
N**
Framing Height
41-1/2”
O (Top Vent)
Framing Depth - Top Vent
20-1/2”
O (Rear Vent)
Framing Depth - Rear Vent
20-3/4”
P (Top Vent)
Corner Wall Depth
48-5/8”
P (Rear Vent)
Corner Wall Depth
53” (Astrocap XL)
61-1/2” (all other approved caps)
Q (Top Vent)
Corner Facing Wall Width
68-3/4”
Q (Rear Vent)
Corner Facing Wall Width
75” (Astrocap XL)
87” (all other approved caps)
R (Rear Vent)
Framed Chase Ceiling -
Rear
41-1/2”
R (Top Vent)
Framed Chase Ceiling - Top
50-1/2”
S (Rear Vent)
Vent Centerline Height -
Rear
26-1/2”
S (Top Vent) 5” x 8”
Vent Centerline Height - Top
44-1/4”/Rigid
|
42-1/8” Flex
S (Top Vent) 4” x 6-5/8”
49” Rigid
T
Gas Connection Height
1-1/2”
U
Gas Connection Inset
4-1/8”
V
Gas Connection Width
3-1/4”
Framing Dimensions:
**
Important: Framing height requires consideration of the hearth
depth. Dimension N = N + the thickness of installed hearth.
M
N
O
Q
P
R
U V
T
Opening for gas
connection
11" (279mm)
dia. Hole through
wall Vent.
Non-Combustible
Header
(steel stud)
Drywall
(or other
facing)
W
Non-Combustible Facing
S
S
Non-Combustible
Header
(steel stud)