background image

Owners &

Installation

PLEASE KEEP THESE INSTRUCTIONS FOR 

FUTURE REFERENCE

 

Manual

Dec-21-11

919-096

WARNING:  
Improper installation, adjustment, alteration, service or maintenance can 
cause injury or property damage. Refer to this manual. For assistance or 
additional information consult an authorised installer, service agency or 
the distributor.

FOR YOUR SAFETY
Do not store or use petrol or other fl ammable vapours and liquids in the 
vicinity of this or any other appliance.

Installation and service must be performed by an authorised installer, 
service agency or the gas supplier.

Model:  F175B-1

Alterra F175B-1 Freestanding Wood Fire

Содержание Alterra F175B-1

Страница 1: ...fer to this manual For assistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer service agency or the gas supplier Model F175B 1 Alterra F175B 1 Freestandi...

Страница 2: ...rea Keep those REGENCY FIRES burning SAFETY NOTE If this wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine...

Страница 3: ...ation 6 Side Panel Installation 7 Fan Installation 7 Clearance to Combustibles 8 Floor Protection 8 OPERATING INSTRUCTIONS Operating Instructions 9 Air Slide Control 9 First Fire 9 MAINTENANCE Maintenance 10 Creosote 10 Ways to Prevent Keep Units Free of Creosote 10 Glass Maintenance 10 Door Latch Adjustment 10 Wood Storage 10 PARTS LIST Stove Assembly 11 WARRANTY Warranty 15 ...

Страница 4: ... TO AS NZS 4013 1999 TEST REPORT NUMBER HCMG 06 024 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2011 2012 2013 Fireplace Products Australia Pty Ltd 21 23 South Link Dandenong VIC 3175 TESTED BY HRL TECHNOLOGY PTY LTD TRAMWAY ROAD MORWELL VICTORIA 3840 2007 Date of Manufacture Serial Number 919 095 396 NOTE Regency units are constantly being improved Check the label on the unit and if there is ...

Страница 5: ...Regency Alterra Freestanding Wood Fire 5 UNIT DIMENSIONS PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP PP ...

Страница 6: ... down holes inside the pedestal 11 Do not connect this unit to a chimney serving another appliance SAFETY GUIDELINES AND WARNINGS 1 Never use petrol petrol type lantern fuels kerosene charcoal lighter fuel or similar liquids to start or freshen up a fire in your heater Keep all such liquids well away from the heater while it is in use 2 Keep the door closed during operation and maintain all seals ...

Страница 7: ...LATION SIDE PANEL INSTALLATION FAN INSTALLATION F H A 2 speed fan is supplied and needs to be fitted to the rear of the unit with screws supplied Install side panels with screws as shown in diagram Diagram 1 Side Panel Install Diagram 1 Fan Install ...

Страница 8: ... fibre sheet which has a thermal resistance of 0 8m2 k w for 4mm sheets of cement fibre sheet The flue pipe shall extend not less than 4 6m above the top of the floor protector NOTE Installation must be carried out by a licensed installer in accordance with AS NZS 2918 2001 IMPORTANT 1 The Universal Default flue kit requires one 130o x 900mm stainless reflective shield fitted to the rear of the ac...

Страница 9: ...ports at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire it is important that you fully understand the operation of your draft control CAUTION THIS APPLIANCE MUST BE MAINTAINEDANDOPERATEDATALLTIMES IN ACCORDANCE WITH THES...

Страница 10: ...hen ignited this creosote can result in an extremely hot fire WARNING Thingstorememberincase of a chimney fire 1 Close all draft and damper controls 2 CALL THE FIRE DEPARTMENT Ways to Prevent and Keep Unit Free of Creosote 1 Burn stove with the draft control wide open for about 10 15 minutes every morning during burning season 2 Burn stove with draft control wide open for about 10 15 minutes every...

Страница 11: ...20103 Door Seal Gasket 12 1393000 Pedestal Assembly Part Description 13 1390003 Bottom Rear Plate 14 1396000 Fan Kit Assembly 15 1390004 Black Right Panel 1390007 SS Right Panel 16 1395000 Top Panel 17 1390005 Black Left Panel 1390008 SS Left Panel 18 1390009 Rear Shield 19 4030214 M6X30 Hex Bolt 20 1390011 Fan Air Deflector 21 1390006 Inner Heat Shield 22 4030207 M6X50 Hex Bolt 23 1390010 Clearan...

Страница 12: ...Regency Alterra Freestanding Wood Fire 12 NOTES ...

Страница 13: ...Regency Alterra Freestanding Wood Fire 13 NOTES ...

Страница 14: ...Regency Alterra Freestanding Wood Fire 14 NOTES ...

Страница 15: ...Fireplace Products will not be liable for results or costs of workmanship from unauthorised service persons or dealers At all times Regency Fireplace Products reserves the right to inspect product in the field which is claimed to be defective All claims must be submitted to Regency Fireplace Products by authorized selling dealers It is essential that all submitted claims provide all of the neces s...

Страница 16: ...PLACE PRODUCTS AUSTRALIA PTY LTD 21 23 SOUTH LINK DANDENONG SOUTH VICTORIA 3175 AUSTRALIA NOTE PLEASE RETAIN YOUR INVOICE AS PROOF OF PURCHASE FOR WARRANTY VERIFICATION INCORRECT INSTALLATION IS NOT COVERED BY WARRANTY A SERVICE OR CALLOUT FEE WILL BE CHARGED IN THESE CIRCUMSTANCES ...