FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

920-132a

Classic™

I1150

Wood Insert

03.10.21

Owners & Installation Manual

Installer:

 Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

www.regency-fire.com
French Manual: https://bit.ly/30s3wce
Manuel en Français : https://bit.ly/30s3wce

Tested by:

0219WN027S

Содержание PROFIBUS I1150S

Страница 1: ...t 03 10 21 Owners Installation Manual Installer Please complete the details on the back cover and leave this manual with the homeowner Homeowner Please keep these instructions for future reference www...

Страница 2: ...the building envelope It is against federal regulation to operate this wood heater in a manner inconsistent with operating instructions in this manual This heater is designed to burn natural wood onl...

Страница 3: ...actory Built Fireplace 9 Altering the Fireplace 9 Draft 9 Installing Your Insert 10 Faceplate Trim Optional Bottom Faceplate Fan Support Installation 11 Fan Blower 15 Brick Installation 16 Baffle Inst...

Страница 4: ...T PI CES OBLIGATOIRES POUR L INSTALLATION GAINE DE CHEMIN E HOMOLOGU E EN ACIER INOXYDABLE DE 5 5 PO 140mm ou 6 PO 152mm PI CE EN OPTION VENTILATEUR PI CE NO 172 917 CARACT RISTIQUES LECTRIQUES 115 VO...

Страница 5: ...sert 5 dimensions 1 1 2 38mm With Standard Flue Adaptor 6 152mm Diameter STANDARD FLUE ADAPTOR Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue Measurement from back of faceplate...

Страница 6: ...Insert dimensions 1 1 2 38mm 455 With Offset Flue Adaptor 6 152mm Diameter OFFSET FLUE ADAPTOR Regency Inserts are designed to use either a 5 5 140mm or 6 152mm flue Measurement from back of faceplate...

Страница 7: ...r Canada measured from the fuel loading door Unit I1150 Adjacent Side Wall to Side A Mantel to Top of Unit B Top Facing to Top of Unit C Side Facing D Minimum Hearth Extension E Minimum Hearth Side Ex...

Страница 8: ...naccessible once you have installed your Regency Insert you should either remove or secure it in the open position 6 Inspect your fireplace and chimney prior to installing your insert to determine tha...

Страница 9: ...for any damage or flaws such as burnouts metal or refectory warping 3 Inspection to a minimum of NFPA 211 Level II is recommended All repairs must be made prior to installing an insert The fireplace...

Страница 10: ...the rear of the unit into the fireplace See Diagram 3 En sure that the unit is centered in the existing fireplace and lined up with the flue adaptor 4 Slide the unit back until the flue adaptor is sli...

Страница 11: ...Reproductive Harm www P65Warnings ca gov FACEPLATE TRIM FAN OPTIONAL BOTTOM FACEPLATE FAN SUPPORT INSTALLATION Regular Faceplate Dimensions shown with bottom faceplate fan support attached Oversize F...

Страница 12: ...lder can then be slid into the tool bracket as shown Digital monitor operating door tool bracket Tool holder slid into tool bracket Tool holder Diagram 2A Rear View 4 Position the assembled faceplate...

Страница 13: ...completed faceplate trim assembly to the insert Ensure to align the side faceplate slots with the hex bolts in the mounting brackets and tighten to secure in place Secure the Regency logo plate to the...

Страница 14: ...screws See Diagram 9 Diagram 9 Rear Bottom View Note Fan not exactly as shown 18 Secure the bottom faceplate to the 3 sided faceplate using the 4 supplied bolts washers 19 Discard both side trims tha...

Страница 15: ...sconnec tion when servicing controls Wiring errors can cause improper and dangerous operation WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug f...

Страница 16: ...tions Do not use a grate LyTherm sheet Order of firebrick install a Rear Firebrick b Firebox floor install brick over LyTherm Sheet c Right and left side Firebricks Fire bricks Size 1 4 1 4 x 7 2 4 1...

Страница 17: ...ight base brick and right side wall brick 5 Install leftandrightbafflecoverplate installationofleftbaffleshownbelow Baffle Installation 4 Install the right and left side baffles right side baffle show...

Страница 18: ...our glass by impact purchase your replacement from an authorized Regency dealer only Remove the door from the stove and remove the screws securing the glass retainer Position the glass in the door mak...

Страница 19: ...a tight seal If door is too tight a washer can be removed Recheck door to ensure there is still a tight seal The handle should be approxi mately in the 8 o clock position when door is fully closed Dia...

Страница 20: ...ff both bolts and slide deflector downward push deflector to the back wall of the unit and manoeuver out Install new deflector and hand tighten bolts Ensure positive location of the deflector prior to...

Страница 21: ...may take a minimum of a full year to dry enough Drying may also take longer in damp climates There are a few ways to tell if wood is dry enough to burn efficiently Use as many indicators as possible...

Страница 22: ...Never build a roaring fire in a cold stove Always warm your stove up slowly 3 During the first few fires keep the combustion rate at a moderate level and avoid a large fire Only after 5 or 6 such fir...

Страница 23: ...your stove 4 If you have smoke detectors prevent smoke spillage as this may set off a false alarm 5 Donotoverfireheater Ifthechimneyconnector flue baffle or the stove top begin to glow you are over fi...

Страница 24: ...d before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your stove require no lubrication 4 A small hot fire is preferable to a large s...

Страница 25: ...into hole on left side air channel Align tab on right side air channel with notch on right hand end of air tube Firmly grip center of air tube with vise grips use hammer to tap vise grips from left to...

Страница 26: ...r tubes vermiculite baffles see manual for details 2 Loosen the two 7 16 bolts nuts to remove replace vertical baffle 3 Repeat steps to install new vertical deflector NOTE ENSURE BAFFLE IS PUSHED UP A...

Страница 27: ...e paper should not pull out easily if it does try adjusting the door latch if that doesn t solve the problem replace the door gasket Check and lubricate door hinge latch Use only high temperature anti...

Страница 28: ...l Accent 12 846 306 Replacement Glass Includes Gasket Size 9 1 8 X 15 5 8 13 936 241 Replacement Glass Gasket Sold per foot 4 Feet required 14 846 570 Door Gasket Repair Kit 15 075 077F Glass Retainer...

Страница 29: ...I1150 Regency Wood Insert 29 parts list Main Assembly 1 22 2 18 21 21 4 17 16 8 5 26 6 3 19 24 9 11 25 9 15 13 10 14 12 7 20 20 27...

Страница 30: ...8 000 x 30 DEG BRICK 5 802 147 1 3 500 x 4 500 BRICK 4 802 152 2 2 000 x 9 000 BRICK 3 902 111 3 9 000 x 4 500 STANDARD BRICK 2 RD 14289 2 4 500 x 7 000 BRICK 1 RD 14288 2 4 250 x 7 000 BRICK Brick P...

Страница 31: ...64 65 60 62 61 64 65 60 62 58 59 60 Faceplate Right Side Regular Oversize 61 Faceplate Left Side Regular Oversize 62 Faceplate Top Regular Oversize 64 Bottom 1 Piece Faceplate 65 Fan Support N S 171 5...

Страница 32: ...1 Catalyst Combustor 10 Years Prorated Venting Chimney 1 Screens 1 See specific warranty details in regards to the catalyst combustor in unit manual Conditions Warranty protects against defect in manu...

Страница 33: ...ct chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels such as unseasoned cordwood mill ends construction lumber or debris off cuts treat...

Страница 34: ...the above limitations or exclusions may not apply to you Customers located outside the U S should consult their local provincial or national legal codes for additional terms which may be applicable t...

Страница 35: ...for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Pr...