918-670g

WARNING:  
Improper installation, adjustment, alteration, service or maintenance can 
cause injury or property damage. Refer to this manual. For assistance or 
additional information consult an authorised installer, service agency or 
the distributor.

FOR YOUR  SAFETY
Do not store or use petrol or other flammable vapours and liquids in the 
vicinity of this or any other appliance.

Installation and service must be performed by an authorised installer
or service agency.

Model:  F180B-2

RENMARK FREESTANDING WOOD FIRE

FPI - FIREPLACE PRODUCTS AUSTRALIA PTY LTD.  

1-3 CONQUEST WAY HALLAM VICTORIA 3803

Содержание F180B-2

Страница 1: ...ssistance or additional information consult an authorised installer service agency or the distributor FOR YOUR SAFETY Do not store or use petrol or other flammable vapours and liquids in the vicinity of this or any other appliance Installation and service must be performed by an authorised installer or service agency Model F180B 2 RENMARK FREESTANDING WOOD FIRE FPI FIREPLACE PRODUCTS AUSTRALIA PTY...

Страница 2: ...wood fire is not properly installed a house fire may result For your safety follow the installation instructions contact local building fire officials or authority having jurisdiction about restrictions and installation inspection requirements in your area The authority having jurisdiction should be consulted before installation to determine the need to obtain a permit ONLY CLEAN APPLIANCE WITH A ...

Страница 3: ...9 Wiring Diagram 10 Installing the Optional Fan 10 PARTS LIST Heater Assembly 11 WARRANTY Warranty 12 Compliance Plate 4 Unit Dimensions 5 INSTALLATION Residential Installation 6 Safety Guidelines and Warnings 6 Brick Installation 6 Clearance to Combustibles 7 Floor Protection 7 OPERATING INSTRUCTIONS Operating Instructions 8 Air Slide Control 8 First Fire 8 Fan Operation 8 Fan is an optional extr...

Страница 4: ...C Updated data as per Matt M May 21 15 Rev D new test results 2 model Sept 25 17 Rev E Updated manufacturing date Model RENMARK F180B 2 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC 2021 2022 2023 2024 2025 TESTED BY HRL TECHNOLOGY PTY LTD TRAMWAY ROAD MORWELL VICTORIA 3840 May 2015 MAXIMUM AVERAGE HEAT OUTPUT BURNING HARDWOOD 10kW without fan fitted OVERALL AVERAGE EFFICIENCY BURNING HARDWOOD 6...

Страница 5: ...Regency Renmark Freestanding Wood Fire 5 DIMENSIONS dimensions 464mm ...

Страница 6: ...egintoglow you areoverfiring Stopaddingfuelandclosethe draftcontrol Overfiringcancauseextensive damage to your heater including warpage and premature steel corrosion Overfiring will void your warranty 6 Do not permit creosote or soot build up in the flue system Check and clean flue at regular intervals Failure to do so can result in a serious flue fire 7 Your Regency heater can be very hot You may...

Страница 7: ... a licensed installer in accordance with AS NZS 2918 2001 Hawkwind Standard 1 Default Kit AHD Special Insulated 2 IMPORTANT 1 The Hawkwind Standard flue kit requires a 130o x 900mm stainless reflective shield between the decromesh casing and ac tive flue If no additional shielding is added to the Standard default Hawkwind kit the rear wall clearance is 325mm 2 The AHD Special Insulated flue kit mu...

Страница 8: ...he unit To increase your draft pull open and to decrease push closed All units have a secondary draft system that continually allows combustion air to the induction ports at the top of the firebox just below the flue baffle OPERATING INSTRUCTIONS With your unit now correctly installed and safety inspected by your local authority you are now ready to start a fire Before establishing your first fire...

Страница 9: ...asoning process MAINTENANCE It is very important to carefully maintain your heater including burning seasoned wood and maintainingacleanheaterandfluesystem Have the flue cleaned before the burning season and as necessary during the season as creosote deposits may build up rapidly Moving parts of your heater require no lubrication The integrity of all heater parts including baffle plates cast iron ...

Страница 10: ... Renmark Freestanding Wood Fire maintenance INSTALLING THE OPTIONAL FAN Note Thermodisc temp switch in the fan control circuit Heater Thermodisc must come up to operating temperature for fan to operate See page 8 ...

Страница 11: ...0106 Neoceram Glass W Gasket 12 1154400 Heat Shiekd L 13 1154500 Heat Shiekd R 14 8010201 Top Panel 15 1141800 Secondary Air Tube 8010611 Steel baffie optional A 7510206 Cast Plate Set optional B 16 8010115 Glass Retainer Bracket 17 1141400 Metal lip inside firebox 18 3720103 Door rope seal 5 ft 19 1141004 Rear Baffle Brick Support Bar 20 1154300 Top Plate 21 1151700B Air Slide Fasteners 3 pcs 5 1...

Страница 12: ... Drawer Heatshields Pedestal 1 All Baffles Steel Ceramic Vermiculite 1 All castings firebox surrounds doors panels etc 1 All Electrical Fans wiring switches etc Fan only 1 Glass Crazing 1 Catalyst Assembly see below for specific details 6 Years Prorated 3 Flue components 1 Firebricks Nil Nil After the original warranty coverage for any of the parts above have expired any repair and or replacement ...

Страница 13: ... for results or costs of workmanship of unauthorised FPI dealers or agents in the negligence of their service work Additional service fees may apply if you are seeking warranty service from a dealer other than the dealer from whom you originally purchased the product At all times FPI reserves the right to inspect reported complaints on location in the field claimed to be defective and determine wh...

Страница 14: ...ing appliances Any unit showing signs of neglect or misuse will not be covered under the terms of this warranty policy and may void this warranty This includes units with rusted or corroded fireboxes which have not been reported as rusted or corroded within three 3 months of installation purchase Any alteration to the unit which causes sooting or carboning that results in damage to the exterior fa...

Страница 15: ...ted to at the option of the supplier one or more of the following i replacement of the goods or the supply of equivalent goods ii the repair of the goods iii the payment of the cost of replacing the goods or of acquiring equivalent goods or iv equivalent goods or v the payment of the cost of having the goods repaired b To the extent that services supplied by the supplier are services other than se...

Страница 16: ...place Products Australia Pty Ltd does not provide installation services Fireplace Products Australia Pty Ltd 1 3 Conquest Way Hallam VIC Australia 3803 Phone 61 3 9799 7277 Fax 61 3 9799 7822 To obtain warranty service in Western Australia and or New Zealand please contact one of our authorised distributors in those areas Western Australia Air Group Australia 28 30 Division St Welshpool WA Austral...

Страница 17: ...low in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchase...

Страница 18: ...18 Regency Renmark Freestanding Wood Fire ...

Страница 19: ...Regency Renmark Freestanding Wood Fire 19 ...

Страница 20: ...__________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial _____________________________________________________________ ...

Отзывы: