Manual - TC.P Quadro
TopControl application
2016-08-05
190/330
V04.52
6
“General setup” group on the <FUNCGEN> tab
2
1
2
4
3
Fig. 111
“General setup” group on the <FUNCGEN> tab.
<FUNCGEN> tab
– “General setup” group
1
“General enable”, check box
Selected:
The function generator is switched on.
Parameters can be entered.
Cleared
The function generator is switched off
Entire register is not available.
No parameters can be entered.
2
“Used Function Blocks”,
group of check boxes
The following reference values can be selected separately or in combination
to define one or more function blocks: “Voltage”, “Current”, “Power”
3
<Import from file...>/<Export to file...>,
buttons
Saves or loads a function sequence from the file system on the computer. For
further information see Fig. 113, page 193.
4
<Load from Flash...>/<Store to Flash…>,
buttons
Saves or loads a function sequence from the internal non-volatile memory
(flash) in the TopCon power supply.
For further information see Table 111, page 192.
Table 110