background image

Wiring to Motion Light &

Standard Fixture

(Standard)

Two Motion Lights

RED to
BLACK

BLACK

BLACK

WHITE

WHITE

BLACK

OPTIONAL WIRING:

One Motion Light

BLACK

WHITE

1. Connect Bare wire

to ground screw

3. Black to black

2. White to white

Ground

Screw

Notch

Junction

Box

Screws

Fixture

Screw

Fixture

Screw

Remove ground screw and 2 fixture screws
from the mounting plate. Flip plate over and
rotate 90

°

. Re-insert ground screw. Insert the

2 fixture screws in the holes near the junction
box screws holes. Route wires through notch
in adaptor plate.

When wiring to additional standard
fixture only
: Strip the motion sensor's
red  wire and connect to the standard
light's black wire. Connect all white wires
together. Total fixture ratings must not
exceed 400W (3.3 A.).

Turn power off at circuit breaker.

INSTALLATION

Junction

Box

Horizontal Junction Boxes Only:

1. Remove

two nuts.

2. Remove

Mounting Plate.

4. Screw in mounting

plate to junction box.

MAX

SENS

MIN

3. Set sensitivity range

on fixture back.

Caulk fixture  and mounting surface
with silicone weather sealant.

Install  three 60W bulbs in candelabra
style lights.

Slide the fixture onto

the mounting screws

and tighten nuts.

Отзывы: