37
REER S.p.A. - Via Carcano, 32 - 10153 Torino, Italy - Internet: www.reersafety.com - e-mail: [email protected]
8541205 - rev
.1 - 02/09/2019
Electrical connections/Operating modes
SAFEGATE TRX
ACTIVE ELEMENT
24VDC (1), Brown
GND (2), Blue
PE
PE (5), Pink
+24Vdc
GND
SEL_B (11), Pink/Grey
4 SENSORS, SEQUENTIAL, TIMEOUT 30s
24VDC (1)
OSSD1 (3)
(Brown) (White)
4 SENSORS, SEQUENTIAL, TIMEOUT ∞
24VDC (1)
OSSD2 (4)
(Brown) (Green)
2 SENSORS, “TX” MODE, TIMEOUT 30 s
OSSD2 (4)
OSSD1 (3)
(Green)
(White)
2 SENSORS, “TX” MODE, TIMEOUT 9 hours
OSSD1 (3)
OSSD2 (4)
(White)
(Green)
2 SENSORS, “L” MODE, TIMEOUT 30 s
OSSD1 (3)
24VDC (1)
(White)
(Brown)
2 SENSORS, “L” MODE, TIMEOUT 9 hours
OSSD2 (4)
24VDC (1)
(Green)
(Brown)
4 SENSORS CONCURRENT, TIMEOUT 30 s
OSSD2 (4)
OSSD2 (4)
(Green)
(Green)
4 SENSORS CONCURRENT, TIMEOUT 9 hours OSSD1 (3)
OSSD1 (3)
(White)
(White)
MUTING OPERATION
1 - WIRING CONFIGURATION
MUTING MODES OF OPERATION (MANUAL MODE)
SEL_A (6), Yellow
* (See diagram 2 for Override/EDM/Mu�ng Enable
configura�on in Manual)
OVERRIDE1_RST, (10)
Violet
OVERRIDE2 (9), Red
EDM (8), Grey
MUT_ENABLE (7)
Black
}
*
}
*
APPENDIX A1: SM - SMO MODELS WIRING SAMPLES - MANUAL MODE