MOSAIC M1S - MASTER MODULE
E
n
g
li
s
h
TECHNICAL FEATURES
PARAMETER
VALUE
PFH
d
(IEC 61508:2010)
1,44E-08
Rated voltage
24VDC
20%
Dissipated power
3W max
Digital INPUTS
(No./description)
8 / PNP active high according to EN 61131-2
INPUT FBK/RESTART
(No./description)
4 / EDM control / possible Automatic
or Manual operation with RESTART button
Test OUTPUT
(No./description)
4 / to check for short-circuits - overloads
Signaling OUTPUTS
(No./description)
4 / programmable - PNP active high
OSSD (No./description)
4 single outputs (or 2 dual channel outputs), cat. 4
400mA@24VDC max
Interface type C class 3 (ZVEI CB24I)
Slot for MCM card
Available
Connection to PC
USB 2.0 (Hi Speed) - Max cable length: 3m
Connection to slave units
via MSC 5-way ReeR proprietary bus
Precise, complete compliance with all standards, instructions and
warnings in MOSAIC handbook is essential for the correct operation of
MOSAIC controller.
ReeR therefore declines any responsibility for all and anything resulting
from failure to comply with all or some of the aforesaid instructions.
The MSD software and manuals are available at URL:
https://www.reersafety.com/download