5 Product specifications
30 of 80
FlexiMova
®
mm - Design and Installation
.
Table 23
: Personal protective equipment - PPE
Mandatory PPE for all authorised operators
GLOVES
(To protect hands against direct contact when working live or close to live parts
1000 V - EN 60903:2003)
GLOVES
(For protection against heat)
ELECTRICALLY INSULATING FOOTWEAR
(To protect the wearer against electric shock when working live or close to live parts
EN 20344:2004/A1:2007, EN 20347:2004/A1:2007, EN 50321:1999)
FOOT PROTECTION
(Protective and safety footwear)
PROTECTIVE CLOTHING
(For protection of the body against direct and indirect action of current by contact or at a
distance when working live with low voltage EN 340:2003, EN 11612:2008 and EN 50286:1999)
HELMET
(Head protection against direct contact up to 440 V – EN 397:1995/A1:2000)
FACE SHIELD
(Face protection against UV rays – electric arcs - working live or close to low-tension live
parts - EN 166:2001, EN 168:2001, EN 170:2002)
5.14
Tools
The tools (screwdrivers, shears, pliers, etc.) used by authorised persons for
servicing the product must be suitable
a
.
nd comply with the current regulations and bear the following marking:
Double triangle symbol.
Manufacturer’s name.
Year of manufacture.
5.15
Protective devices
5.15.1
Fuses
The input bridge must be protected against overload or sudden current surges
with
rapid
or
ultra rapid fuses
sized according to the product’s rated output
current (
IaN
) and technical characteristics.
The tables below indicate the maximum
I
2
t
(A
2
/s) value of the fuse
recommended by the Manufacturer to ensure correct protection of the
product. The tables have been prepared in compliance with the relevant
regulations (EC normative references). When selecting the appropriate fuse,
the following factors must be taken into consideration :
The nominal value of the fuse’s rms current which
must be greater
than the declared nominal output current.
The temperature derating, therefore possible oversizing.
Overload index and service class.
The rated voltage (
≥
600 VAC).
The I
2
t value of the fuse used which
must be less than
the value
indicated in the following table.
.
.
.
.
.
.