REEFE DIAPHRAGM LINEAR AIR PUMP INSTRUCTION MANUAL                           

MODELS: RB80 – RB90 – RB100 

Thank you for purchasing a REEFE Linear Air Pump.  These pumps feature double air chambers to 
produce a high volume of air and strong air pressure. High performance and low noise; weatherproof 
design, suitable for indoor and outdoor use; fast heat dissipation, non-oil lubricated design to provide 
uncontaminated air delivery.  REEFE Diaphragm Air Pumps are especially developed for a high air 
output, even in deep water.  The pump is also suitable for aerating breeding systems, waste water 
treatment systems  with  multiple  air  outlets.   For  optimum  performance  and  safety, please  read  this 
instruction manual carefully and keep it handy for future reference.   

 
PRODUCT FEATURES 

1.  Artificial rubber diaphragms to ensure a steady air output and pressure. 
2.  Advanced air-delivery system and muffler for low noise. 
3.  Special cut-off switch if the Diaphragm splits, to avoid pump damage.  
4.  Compact design with long service life and low energy consumption. 
5.  Aluminium alloy case provides quick heat-dissipation and reduces overall weight. 

 

INSTALLATION 

1.  Installation and electrical wiring must adhere to state and local codes and must be completed before using the pump. These 

pumps  come  with  an  earthed  power  plug  and  all  electrical  installations  must  be  earthed.  Any  Electrical  work  must  be 
performed by a licenced Electrician.  

2.  IMPORTANT; The Pump must be connected to a suitable electrical circuit, protected by a RCD (safety switch), all warranty is 

void if there is no RCD protection. Do not use an extension lead, the pump must be connected directly to a power outlet. All 
warranty is void if this instruction is not followed.  Note: Use of extension leads may cause low voltage supply to the motor, 
causing blown fuses, tripping of motor overload, or burnt out motor, which will not be covered by the Warranty. If the pump is 
hard-wired to the electrical circuit, we are not responsible for the costs involved if the product needs to be replaced, as we 
have no control over the installation method. We do not recommend hard-wiring this product.  

3.  IMPORTANT:  use a DRIP LOOP in the power cable so as any water or condensation that forms on the cable will drip off the 

cable and not enter the power outlet.  

4.  Surge Protection - We recommend that a surge protector is used to protect the electronics of this pump, as damage due to 

power surges is not covered by the Warranty. 

5.  IMPORTANT: ALWAYS disconnect from the power supply before touching the pump.  
6.  MOUNTING: This product must be installed on a flat, horizontal surface, protected from the weather. Mount the product on a 

stable, rigid surface.  If necessary, additional rubber mounts will reduce noise and vibration. 

7.  PLUMBING:  Remove the plug from the discharge port. Connect with pipe and fittings that are the same size or larger than the 

pump discharge port, suitable to your installation; ensure all pipes are secured well to prevent leakage.  Using larger bore pipe 
and avoiding sharp bends will improve performance.   

8.  AIRSTONES:  Use new and sufficiently large air stones or diffusers with suitable discharge capacity.  Place them no deeper 

than 3m in the water body.  Bends in the air pipe, air stones that are placed too deep, air stones that are too small, old or dirty 
air stones, will drastically reduce performance.  When the pump is on, never fully close off the pump outlet.  Ensure that the 
pump can discharge sufficient air at all times, otherwise overheating will lead to damage.  

9.  ACCESSORIES: Use only recommended air fittings and pipework or tubing that is designed for pressure not less than 0.7bar 

(10psi).  

10.  BACKFLOW: To prevent any water flowing back into the pump when turned off, it is critical to install the pump above water 

level.  If a non-return valve is used on the outlet pipe, the pump may be installed lower than the waterline, at the installers risk, 
we do not recommend this type of installation.  Pump must NEVER BE SUBMERGED IN WATER.  

11.  Install relief valve and gauge at the discharge, to allow you to monitor performance 
12.  To guarantee longest possible service life, install the pump in a well-ventilated, dry, moisture and dust-free place.  Dirt, dust, 

Chlorine fumes, other gases and moisture will shorten the service life of this pump and/or can be hazardous. NEVER use the 
pump if it is not in a place with clean fresh air.  Please note that in an ambient temperature above +40°C, the diaphragm will 
prematurely age and will be more likely to crack

.

 

 
DIAPHRAGM BREAKAGE SWITCH 

The Diaphragm Breakage Switch system stops the pump when the diaphragm is split or punctured.  This causes an unusual longer 
stroke of the magnet, which then actuates the microswitch on top of the motor cover (inside the pump, part number 6 & 8 in the below 
diagram) and automatically shuts down the power.  See DIAPHRAGM REPLACEMENT instructions below .  

 

 
FILTER SPONGE CLEANING INSTRUCTIONS 

Any dust or foreign matter lodged in the pump inlet will cause abnormal noises and/or result in failure of the pump.  The filter sponge 
must be inspected after the first 500 hours of operation, and cleaned or replaced at least every three months.   

1.  Unplug the pump first before cleaning & replacement work. Remove the air inlet cover from the top of the housing. 
2.  Remove the filter sponge from the air inlet.  At the same time, remove any dust or foreign matter from the air inlet, the air inlet 

cover  and  the  filter  sponge  mounting  surface.    If  the  sponge  is  soiled,  a  piece  of  new  sponge  is  needed  or  you  can  use  a 
neutral  detergent  to  wash  the  old  sponge.    Remember  to  rinse  it  thoroughly  with  water  and  dry  it  out  in  the  sun  before 
reinstalling.  Detergent is detrimental to fish and other aquatic life. 