• Measures temperature, humidity, heat index,
and dew point
• Displays day, date, & time
• Stopwatch/chronograph mode with 1/100
second resolution
• 99 lap and 30 lap/split memory
• 12 or 24 hour clock operation
• Silent operation option
• Dual power: solar panel & battery
• 1 ATM water resistant (IPX4 rated)
Features
Instrument Description
Timing Capacity
: 9:59:59"
Accuracy
: ±3 seconds/day
Lap Memory
: 30 laps
Heat Index Range
: 70 to 122°F (22 to 50°C)
Temp. Range
: 23 to 122°F (-5 to 50°C)
Accuracy:
±1.8°F (1.0°C)(32 to 104°F(0 to 40°C))
±3.6°F (2°C)
Humidity Range
: 1 to 99% RH
Accuracy:
±5% RH (40% to 70%)
±8% RH (Other)
Dimensions
: 2.65 x 3.6 x 0.9"
(67.5 x 92 x 23mm)
Weight
: 2.93oz (83g)
In Normal time mode, press the Start/Stop
or the Lap/Reset button to turn the Key
Tone on and off.
Press the Light button to turn the backlight
on. The backlight will stay on for 5 seconds.
Shows minute, second and day of the week.
Press the Mode button once to select Normal mode.
1.
Month
4.
Key tone symbol
2.
Day of week
5.
Date
3.
Time
1.
LCD
2.
Lap/Reset button
3.
Recall button
4.
Mode button
5.
Start/Stop button
6.
Solar panel
7.
Light button
Set a specific time for the alarm to go off.
Press the Mode button eight times to enter Alarm
Time mode. Press and hold the Recall button to
modify the alarm time. The first digit flashing is the
hour. Press the Start/Stop button to adjust the
number. Press the Lap/Reset button to adjust the minute and the Start/Stop button
to adjust the number. Press the Mode button to save the countdown time, or wait 30
seconds. The alarm is automatically turned on after the time is set. Press any button to
stop the alarm when it is going off. The alarm will ring for 30 seconds.
1.
Normal time
3.
Alarm icon
2.
Alarm time
4.
Alarm mode
In Normal time mode, press and hold the Recall button to enter Time and Calendar
setup mode. The first digit flashing is the second. Press the Start/Stop button to bring
the seconds to 00. Press the Lap/Reset button to adjust the minute and the Start/Stop
button to adjust the number. Press the Lap/Reset button to adjust the hour and the
Start/Stop button to adjust the number. Continue adjusting the year, month, and date.
The last setting switches between the 12 & 24 hour clock. Press the Start/Stop button to
switch between the two. Press the Mode button to save and exit the Time and Calendar
setup mode, or wait 30 seconds.
In order to conserve the batteries, make sure the solar panel is exposed to light. If the
LCD appears dim even in sufficient light you will need to replace the batteries. Remove
the screws from the back of the Stopwatch and place a new CR2032 battery in the
battery compartment. Be sure to observe the correct polarity.
Countdown a specific amount of time and how
many times the countdown has cycled. Press the
Mode button seven times to select Countdown mode.
Press and hold the Recall button to modify the
countdown time. The first digit flashing is the hour.
Press the Start/Stop button to adjust the number. Press the Lap/Reset button to
adjust the minute and the Start/Stop button to adjust the number. Press the Lap/
Reset button to adjust the second and the Start/Stop button to adjust the number.
Press the Mode button to save the countdown time, or wait 30 seconds. The
maximum time you can set is 9:59:59. Press the Start/Stop button to start and stop
the countdown. The maximum countdown cycle amount is 99 cycles.
1.
Countdown Cycle Times
2.
Current lap time
3.
Stopwatch
Combines the temperature & humidity to display the
human-perceived temperature. Press the Mode button
three times to select Heat Index mode. Press the Start/
Stop button to switch between °C/°F.
1.
Heat Index Temperature
Dew Point is the temperature at which the air can no
longer "hold" water vapor and must condense. Press
the Mode button four times to select Dew Point mode.
Press the Start/Stop button to switch between °C/°F.
1.
Dew Point Temperature
Displays the ambient temperature and humidity.
Press the Mode button twice to select Temperature
and Humidity mode. Press the Start/Stop button to
switch between °C/°F.
1.
Humidity
2.
Temperature
Specifications
Key Tone setting
Backlight
Normal time mode
Alarm Time mode
Time and Calendar setup mode
Battery Replacement
Heat Index mode
Dew Point mode
Measure the time spent per lap. Press the Mode
button five times to select Lap mode. Press the
Start/Stop button to start the first lap. Press the
Lap/Reset button to log the first lap and start the
second lap. Press the Mode button to exit Lap mode.
1.
Lap number
2.
Current lap time
3.
Stopwatch
Lap mode
Countdown mode
Measure the whole split time from the beginning.
Press the Mode button six times to select Split Time
mode. Press the Start/Stop button to start. Press the
Lap/Reset button to log the first split and start the
second split. Press the Start/Stop button to stop
measuring and to display the split data. Press the Mode button to exit Split mode.
1.
Split number
2.
Current split time
3.
Stopwatch
Split Time mode
Temperature and Humidity mode
reedinstruments
www
com
Model
SW700
Heat Index Stopwatch
REED Instruments
1-877-849-2127 | [email protected] | www.reedinstruments.com