Страница 1: ...ST 882 Model Infrared Thermometer reedinstruments www com Instruction Manual ...

Страница 2: ...d preparation Safety and Fire inspectors Plastic molding Asphalt Marine and screen printing measures ink and dryer temperatures Diesel and Fleet maintenance Field of View Meter s field of view is 8 1 meaning that if the meter is 8 inches from the target the diameter of the object under test must be at least 1 inch Other distances are shown below in the field of view diagram Refer to the chart prin...

Страница 3: ... F RESPONSE TIME Less than 1 second OVER RANGE INDICATION LCD will show 1 POLARITY Automatic no indication for positive polarity Minus sign for negative polarity EMISSIVITY 0 95 fixed value FIELD OF VIEW D S Approx 8 1 ratio D distance S spot Has 90 encircled energy at the focal point DIODE LASER Output 1mW Wavelength 630 670nm class 2 II Laser product SPECTRAL RESPONSE 6 14um POWER OFF Automatic ...

Страница 4: ...n Accuracy 5 C to 20 C 58 F to 4 F 0 1 C 5 C 9 F 20 C to 280 C 4 F to 536 F 2 of reading or 2ºC 4 F 201 C to 538 C 330 F to 1000 F 1 C 2 of reading or 2ºC 4 F Note Accuracy is given at 18 C to 28 C 64 F to 82 F less than 80 RH Emissivity 0 95 fixed value Field of View Make sure that the target is larger than the unit s spot size The smaller the target the closer you should be to it When accuracy i...

Страница 5: ... SCAN display icon will appear in the upper left hand corner of the LCD 4 While continuing to squeeze the Trigger a Push the Laser button to turn on the laser pointer When the laser is on the laser icon will appear on the LCD over the temperature Aim the red beam approximately a half inch above the point of test pressing the Laser button again turns the laser off b Select the temperature units C o...

Страница 6: ...t temperatures Several minutes is required after a low temperature is measure before a high temperature measurement can be measured This is a result of the cooling process which must take place for the IR sensor 6 BATTERY REPLACEMENT 1 When battery power is not sufficient the LCD will display Replacement with a 9V battery is required 2 Open the battery cover take out the battery from instrument an...

Страница 7: ...Page 1 Locating a Hot Spot To find a hot spot aim the thermometer outside the area of interest then scan across with an up and down motion until you locate hot spot Reminders 1 Not recommended for use in measuring shiny or polished metal surfaces stainless steel aluminum etc See Emissivity below 2 The unit cannot measure through transparent surfaces such as glass It will measure the surface temper...

Страница 8: ...80 Sand 0 90 Charcoal powder 0 96 Earth 0 92 to 0 96 Lacquer 0 80 to 0 95 Water 0 92 to 0 96 Lacquer matt 0 97 Ice 0 96 to 0 98 Rubber black 0 94 Snow 0 83 Plastic 0 85 to 0 95 Glass 0 90 to 0 95 Timber 0 90 Ceramic 0 90 to 0 94 Paper 0 70 to 0 94 Marble 0 94 Chromium oxides 0 81 Plaster 0 80 to 0 90 Copper oxides 0 78 Mortar 0 89 to 0 91 Iron oxides 0 78 to 0 82 Brick 0 93 to 0 96 Textiles 0 90 ...

Страница 9: ...______________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ ________________________________________________ __________________________________________...