Model

C-380

Refrigerant  

Leak Detector

Instruction

Manual

Pantone 534 Blue

Pantone 123 Yellow

Pantone 485 Red

Pantone 123 Yellow

Pantone 534 Blue

Black

Rich Black - 

20/20/20/100

Blue -  100/80/30/5

Yellow - 0/27/100/0

Red - 10/100/100/5

Yellow - 0/27/100/0

Blue -  100/80/30/5

Only if you REALLY need them:

Pantone 534 Blue -  100/80/30/5

Pantone 485 Red - 10/100/100/5

Pantone 123 Yellow - 0/27/100/

INSTRUMENTS

1.888.610.7664 

[email protected]

REED-Direct.com

Содержание C-380

Страница 1: ...nts www com Model C 380 Refrigerant Leak Detector Instruction Manual Black Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Pantone 123 Yellow 0 27 100 1 888 610 7664 info REED Direct com REE...

Страница 2: ...0 5 Pantone 485 Red 10 100 100 5 Table of Contents Safety 3 Features 3 Specifications 4 Instrument Description 5 Operating Instructions 6 8 Power Up Reset 6 Testing the Unit 6 Measuring 6 Ambient Conc...

Страница 3: ...nsure your safety and the proper use of this unit Features Detects and pinpoints even the smallest leaks of refrigerant gases An increasing tick rate sounds as a leak is pinpointed and the red indicat...

Страница 4: ...Hi 6g year L 30g year R404A 407C 410A Hi 8g year L 40g year Alarm Settings Buzzer Tricolour LED bar indicator Sensor Advanced ionization detection Response Time Less than 1 second Warm up Time 10 seco...

Страница 5: ...80 30 5 Only if you REALLY need them Pantone 534 Blue 100 80 30 5 Pantone 485 Red 10 100 100 5 Instrument Description 1 Sensor 2 Sensor Protector 3 LED Leak Indicators 4 Low Sensitivity Button 5 High...

Страница 6: ...serves as an ambient concentration reset button see ambient concentration reset for more information Press ON OFF once to turn on the refrigerant leak detector The LED leak indicators will then illumi...

Страница 7: ...ity switch to HIGH before search ing for any additional leaks When you ve finished testing for leaks turn the unit OFF and store it in a cool dry clean place to protect the sensor and unit from any po...

Страница 8: ...cally This unit s sensor has a limited operative period and under normal operation it should stay operative for over a year To prolong the sensor s life cycle ensure that the sensor s surface is free...

Страница 9: ...attery indicator will illuminate The batteries should be replaced as quickly as possible 1 Loosen the battery cover screw and remove the battery cover located on the bottom of the instrument as shown...

Страница 10: ..._____________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________...

Страница 11: ..._____________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________...

Страница 12: ..._____________________________________ ________________________________________________ ________________________________________________ ________________________________________________ _______________...