background image

Data Logging 

Thermometer

Instruction 

Manual

R2450SD

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание R2450SD

Страница 1: ...Data Logging Thermometer Instruction Manual R2450SD REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 2: ...10 RTD Pt100 Ohm Measurement Mode 10 Measuring the Difference Between Two Measurements T1 T2 11 Data Hold 11 Recording Maximum and Minimum Readings 11 12 Backlight 12 Setup Mode 12 14 Setting the Time and Date dAtE 13 Setting the Data Logging Sampling Rate SP t 13 Enabling Disabling Auto Power Off PoFF 13 Enabling Disabling the Beeper bEEP 13 14 Setting Data Decimal Format dEC 14 Formatting the SD...

Страница 3: ...l and Recycling 22 Product Support 22 Introduction Thank you for purchasing your REED R2450SD Data Logging Thermometer Please read the following instructions carefully before using your instrument By following the steps outlined in this manual your meter will provide years of reliable service Product Quality This product has been manufactured in an ISO9001 facility and has been calibrated during t...

Страница 4: ...surements simultaneously Accepts Type K J R S E T thermocouples and RTD probes Temperature differential T1 T2 Max Min and Data hold functions User selectable C F Real time data logger with integrated SD memory card User selectable sampling rate from 1 to 3600 seconds Easy to read backlit LCD display Tripod mount for long term monitoring Low battery indicator and auto shut off Included Beaded Wire ...

Страница 5: ... 3600 seconds External Memory Yes expandable up to 16GB with SD card optional Auto Shut off Yes after 10 minutes off Kick Stand Yes Tripod Mountable Yes Low Battery Indicator Yes Power Supply 6 x AA Batteries or AC Adapter optional Data Output Yes RS 232 Product Certifications CE Operating Temperature 32 to 122 F 0 to 50 C Storage Temperature 14 to 140 F 10 to 60 C Operating Humidity Range Less th...

Страница 6: ... F 0 to 1700 C 1 F 1 C Type S 32 to 2732 F 0 to 1500 C 1 F 1 C RTD Range Resolution Pt100 Ohm 327 9 to 1562 F 199 9 to 850 C 0 1 F 0 1 C 1 F 1000 Note RTD Pt100 Ohm is an optional accessory R2450SD RTD Accuracy Specifications Thermocouple Accuracy Type K 148 0 to 58 1 F 0 4 1 8 F 58 0 to 999 9 F 0 4 1 F 1000 to 2372 F 0 4 2 F 100 0 to 50 1 C 0 4 1 C 50 0 to 999 9 C 0 4 0 5 C 1000 to 1300 C 0 4 1 C...

Страница 7: ... 0 4 1 F 1000 to 1652 F 0 4 2 F 100 0 to 50 1 C 0 4 1 C 50 0 to 900 0 C 0 4 0 5 C Type R 32 to 3092 F 0 5 5 F 0 to 1700 C 0 5 3 C Type S 32 to 2732 F 0 5 5 F 0 to 1500 C 0 5 3 C RTD Range Pt100 Ohm 327 0 to 999 9 F 0 4 1 8 F 1000 to 1562 F 0 4 2 F 199 9 to 850 0 C 0 4 1 C Note Stated Thermocouple RTD accuracy values are specific to the meter The accuracy of the input probe should be considered whe...

Страница 8: ...ight Button 2 Up T1 T2 Button 3 TIME SET Button 4 LCD Display 5 HOLD Button 6 REC Button 7 Down Type Button 8 Enter Log Button 9 Thermocouple Input Jacks T1 T4 10 PT1 RTD Input Jack 11 PT2 RTD Input Jack 12 RS 232 Output Jack 13 Power Adapter Input 14 Tripod Mounting Screw 15 Battery Cover 16 Kickstand 17 SD Card Slot REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 9: ... Channel 5 Date Time Stamp 6 T4 Channel 4 Thermocouple Input Indicator 7 Data Logging Status Indicator 8 Temperature Unit of Measure 9 Temperature Measurement for T4 Thermocouple Channel 10 Temperature Measurement for T3 Thermocouple Channel 11 T3 Channel 3 Thermocouple Input 12 Thermocouple Input Type 13 Maximum and Minimum Indicator 14 Record Mode Indicator 15 Data Hold Indicator 16 Low Battery ...

Страница 10: ...utton until the desired type appears on the LCD and release to confirm selection 3 The LCD will display the temperature values for the channels in use If an input jack is not in use or the measurement is out of temperature range the screen will display RTD Pt100 Ohm Measurement Mode 1 Connect up to two 2 RTD probes R2450SD RTD to the RTD input jacks labeled PT1 PT2 2 Once one or two RTD probes are...

Страница 11: ... T2 button for 2 seconds Data Hold 1 While taking a measurement press the HOLD button to freeze the current measurement s on the display 2 While in this mode a HOLD symbol will appear on the display 3 Press the button again to resume normal operation Note When the Data Hold feature is active all buttons except the POWER button are disabled Recording Maximum and Minimum Readings 1 Press the REC but...

Страница 12: ... seconds to enter Setup Mode 2 Press the SET button continuously to scroll through the following parameters Parameter Description dAtE Set the time and date SP t Set the data logging sampling rate PoFF Enable or disable the auto power off function bEEP Turn the beeper on or off dEC Set the decimal format USA 20 00 or European 20 00 Sd F Format the SD memory card t CF Select the temperature unit of...

Страница 13: ...30 60 120 300 600 1800 and 3600 seconds 2 Press the ENTER button to confirm selection and skip to next parameter Note At any time you can press the POWER button to exit the setup mode and resume normal operation Enabling Disabling Auto Power Off PoFF Follow steps 1 and 2 when PoFF appears on the LCD 1 Press the and buttons to select between ON enabled or OFF disabled With the Auto Power OFF featur...

Страница 14: ... Select NO to abort 2 Press the ENTER button to confirm selection 3 Press the ENTER button again to re confirm 4 The meter will format the SD card while flashing For and automatically return to the Setup menu when formatting is complete 5 Press the POWER button to exit Setup mode and resume normal operation Note It is recommended that new SD cards be formatted prior to first use If the formatting ...

Страница 15: ...button is pressed to manually log a reading on the inserted SD card at any time In order to setup the meter for manual data logging follow steps 1 through 5 below 1 Set the data logging sampling rate to 0 seconds see Setting the Data Logging Sampling Rate section for details 2 Press and hold the LOG button for 2 seconds at which point the lower portion of the LCD will display P X X memory position...

Страница 16: ...he meter is powered Off remove the SD memory card from the SD card slot 2 Insert the SD memory card into the computer 3 Open the file s with Excel See sample below Place Date Time Value Unit Value Unit Value Unit Value Unit 1 7 10 2019 4 13 07 22 7 T1 KTemp C 22 7 T2 KTemp C 22 7 T3 KTemp C 24 T4 KTemp C 2 7 10 2019 4 13 37 35 T1 KTemp C 38 T2 KTemp C 36 T3 KTemp C 37 T4 KTemp C 3 7 10 2019 4 14 0...

Страница 17: ...oes not have a probe inserted 4 The last measurement value will be displayed on the left side of the LCD while the offset adjusted value will be displayed on the right as shown below SEt oFS 23 7 23 7 5 Press the and buttons to adjust the offset value 6 Press the ENTER button to save the adjusted value and resume normal operation Note The above offset adjustment will be applied to all four inputs ...

Страница 18: ...e a probe inserted 5 The last measurement value will be displayed on the left side of the LCD while the offset adjusted value will be displayed on the right as shown below SEt oFS 23 7 23 7 7 Press the and buttons to adjust the offset 8 Press the ENTER button to save the adjusted value and resume normal operation Note The above offset adjustment will be made for the selected input jack not both At...

Страница 19: ...ttings Bits per second 9600 Data bits 8 Parity None Stop bits 1 41010100000221 Channel T1 22 1 C Reading Decimal Place 0 3 Positive 0 Negative 1 C 01 F 02 Channel T1 1 T2 2 T3 3 T4 4 4 41010100000221 Canal T1 22 1 C Lecture Position décimale 0 3 Positif 0 Negatif 1 C 01 F 02 Canal T1 1 T2 2 T3 3 T4 4 4 3 5mm Terminal to RS 232 Serial Connection REED Instruments 1 877 849 2127 info reedinstruments ...

Страница 20: ...ial and Commercial Temperature Applications R D and Educational Establishments Food Service Accessories and Replacement Parts R2920 Surface Thermocouple Probe R2930 Right Angle Thermocouple Probe R2940 Air Gas Thermocouple Probe R2950 Immersion Thermocouple Probe R2960 Needle Tip Thermocouple Probe TP 01 Beaded Thermocouple R2450SD RTD PT100 Ohm RTD Temperature Probe R1500 Tripod RSD ADP NA Power ...

Страница 21: ...I record for Battery life will depend on a number of factors Quality of Battery Whether the beeper is ON or OFF Whether the backlight is ON or OFF Environmental Conditions during data logging As a reference using alkaline batteries with both the backlight and beeper on while automatic data logging at a 2 second sampling rate the batteries will last approximately 14 hours Product Care To keep your ...

Страница 22: ... or by email at info reedinstruments com to discuss the claim and determine the appropriate steps to process the warranty Product Disposal and Recycling Please follow local laws and regulations when disposing or recycling your instrument Your product contains electronic components and must be disposed of separately from standard waste products Product Support If you have any questions on your prod...

Страница 23: ...Test Measure with Confidence Check out our latest Products REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...

Страница 24: ...REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com ...