Insulation 

Tester

Instruction 

Manual

R5600

 

REED Instruments

1-877-849-2127 | [email protected] | www.reedinstruments.com

Содержание 800837002044

Страница 1: ...Insulation Tester Instruction Manual R5600 REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 2: ...Power Function 8 Low Resistance Continuity Measurements 9 AC DC Voltage Measurement 9 Auto Power Off 9 Data Hold 9 Backlight 9 Battery Replacement 10 Applications 10 Application Notes 10 12 Power Tool...

Страница 3: ...rument Dismantling your product other than for the purpose of replacing batteries may cause damage that will not be covered under the manufacturer s warranty Servicing should only be provided by an au...

Страница 4: ...500V or 1000V test voltages and insulation resistance up to 2000M Lock function and hanging strap for handfree operation Lo function for testing connections Datahold function Double molded plastic ho...

Страница 5: ...esolution 0 1M 1M 1mA General Specifications Range Selection Autoranging Manual Display LCD with dual display Display Hold Yes Sampling Rate 2 5 times seconds Backlit Display Yes Continuity Check Audi...

Страница 6: ...0 200 x 92 x 50mm Weight 25oz 700g Instrument Description 3 4 5 6 7 8 9 HOLD LOCK CONTINUOUS TEST V v HOLD LOCK DC AC R5600 Insulation Tester K M 1 LCD Display 2 HOLD Button 3 TEST Button 4 Rotary Sw...

Страница 7: ...nd electrical shock Insulation Resistance Measurements Warning Do not perform any Insulation Resistance measurements if there is AC Voltage present on the device being tested 1 Connect the test leads...

Страница 8: ...ot include components which will be damaged by the 1000V applied Many normal components of an installation are likely to be damaged if tested at 1000V Examples are power factor correction capacitors l...

Страница 9: ...DCV position 3 Connect the test leads IN PARALLEL to the circuit being measured 4 Note the measured value Auto Power Off To preserve battery life the meter is programmed to turn off after 15 minutes...

Страница 10: ...to the device s housing i e chuck blade etc and the other lead to the end of the power cord AC Motors Testing Disconnect the motor from the line by disconnecting the wires from the motor terminals or...

Страница 11: ...tator If the resistance measurement indicates a weakness raise the brushes off the commutator and separately test the armature field coils and brush rigging by connecting one lead to each of them indi...

Страница 12: ...turn 3 Check insulation resistance between conductors by connecting meter leads to conductors in pairs Accessories and Replacement Parts R5600 STAND Replacement Kickstand CA 05A Medium Soft Carrying C...

Страница 13: ...fective because of improper material or workmanship under normal use and maintenance REED Instruments total liability is limited to repair or replacement of the product REED Instruments shall not be l...

Страница 14: ...ts com Please visit www REEDINSTRUMENTS com for the most up to date manuals datasheets product guides and software Product specifications subject to change without notice All rights reserved Any unaut...

Страница 15: ...TEST MEASURE WITH CONFIDENCE CHECK OUT OUR LATEST PRODUCTS REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...

Страница 16: ...REED Instruments 1 877 849 2127 info reedinstruments com www reedinstruments com...