![Redline RDL-3000 SC Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/redline/rdl-3000-sc/rdl-3000-sc_user-manual_1429320016.webp)
RDL-3000
User Manual
70-00158-01-DRAFT
Proprietary Redline Communications © 2010
Page
16
of 142
November 25, 2010
1.2.2
UL Information
1.
The suitability of the supplied Ethernet cable is subject to the approval of Authority
Having Jurisdiction and must comply with the local electrical code.
2.
The equipment must be properly grounded according with NEC and other local
safety code and building code requirements
3.
To meet the over-voltage safety requirements on the telecommunications cables, a
minimum 26 AWG telecommunication line cord must be used.
4.
"Pour être en conformance avec les exigences finies de sûreté de sur-tension sur les
câbles de télécommunications un fil de télécommunication ayant un calibre minimum
de 26 AWG doit être utilisé."
5.
Reminder to all the BWA system installers: Attention to Section 820-40 of the NEC
which provides guidelines for proper grounding and, in particular, specifies that the
cable ground shall be connected to the grounding system of the building, as close to
the point of cable entry as is practical.
6.
RDL-3000 must be installed in compliance with relevant articles in National
Electrical Code-NEC (and equivalent Canadian Code-CEC) including referenced
articles 725, 800 and 810 in NEC.
7.
RF coaxial cable connecting an antenna to the RDL-3000 must comply with the
local electrical code.