Technical Specifications
Table 39
:
Spec. - RDL-3000 Technical Specifications
RF:
T502 Radio:
RF Band:
4.940 - 5.850 GHz (TDD)
1
Rx Sensitivity:
-89 dBm @ 3 Mbps max.
Center Freq. Steps: 2.5 MHz
2
Channel Size:
5, 10, 20 MHz (firmware selectable)
1
Rx Sensitivity:
-98 dBm @ 3 Mbps max., 5 MHz channel, BPSK
System Capability:
LOS, Optical-LOS, and Non-LOS
> 50 dB Rx Dynamic Range
Maximum Tx Power: 25 dBm (Ave. Max.)
1,3
Minimum Tx Power: -10 dBm
Dynamic Frequency Selection (DFS)
Automatic link distance ranging
Ethernet Data Rate:
Up to 100 Mbps average rate (20 MHz chan.)
4
PoE Cable:
Up to 91 m (300 ft)
5
Over The Air Encryption: AES-128 and AES-256
Node Authentication:
X.509 certificates
Network Attributes:
802.3x Ethernet flow control
Automatic link ranging
DHCP pass-through, Transparent bridge
802.1Q VLAN classification
CIR/PIR Support
Modulation/Coding:
BPSK 1/2, QPSK 1/2, 16 QAM 1/2, 16 QAM 3/4, 64 QAM 2/3 and
64 QAM 3/4
MAC:
Time Division Multiple Access (TDMA)
Automatic Repeat Request (ARQ) error correction (per link)
Dynamic adaptive modulation (per link)
Packet fragmentation, Concatenation
Network Services:
Transparent to 802.3 Services and applications
Duplex Technique:
Dynamic TDD (time division duplex) (per link)
Wireless Transmission:
OFDM (orthogonal frequency division multiplexing)
Network Service:
10/100 Ethernet (RJ-45)
System Configuration:
HTTP/HTTPS (Web) interface, SNMP, SSH, Telnet (CLI), TFTP
Network Management:
SNMP v2c or v3: standard and proprietary MIBs
Power Requirements:
Standard IEEE 802.3at PoE (25 W max.)
Operating Temperature: -40 C to 60 C (-40
o
F to 140
o
F)
Dimensions/Weight:
290.7 mm x 268.4 mm x 63.5 mm (11.45 in x 10.57 in x 2.50 in)
Ingress Protection:
IP67
Weight:
2.7 Kg (6 lb) without bracket or antenna
Storage Temperature:
-50 C to 70 C