Step 8
Ensure RF cables are not located next to high voltage cables. Ensure all cables are clearly
labelled.
Step 9
Log all of your results and store the inspection results with your maintenance records.
Rebooting the Devices
Most changes that you make to the sector controller configuration require that you save
the changes and then reboot the device in order to activate your changes.
Changes made to the subscriber unit configuration may also require that you save the
changes and then reboot the device in order to activate your changes.
This procedure is service impacting and should only be performed during a scheduled
maintenance window. However, in general the interruption is only a few minutes and could
be done during a period of low network activity.
Rebooting the AN100U/UX
Step 1
Log into the sector controller and scroll to the bottom of the main menu.
Step 2
Click on the Reboot button at the bottom of the main menu.
The device will terminate all of its connections and reboot itself. This will typically take 1-2
minutes. Any configuration changes that were made will now be active.
Step 3
Verify your changes and ensure the device is operating as expected.
Backing up, restoring and upgrading the sector controller software is covered in the
RedMAX AN100U/UX Base Station User Guide.
Rebooting the Subscriber Unit
Step 1
Log into the sector controller and click SS Info in the menu.
Step 2
Click on the Reset button at the top of the page.
The device will terminate all of its connections and reboot itself. This will typically take 1-2
minutes. Any configuration changes that were made will now be active.
Step 3
Verify your changes and ensure the device is operating as expected.
Redundant Power Supply
The redundant power supply (RPS) is a stand-alone power supply that can be used as a
backup power supply for deployments of up to six AN100UX base stations. The RPS can
support one AN100UX unit with a failed power supply. It is not intended to be used as an
uninterruptable power supply (UPS).