AN-80i
Installation Guidelines
70-00073-01-08-b
Proprietary Redline Communications © 2011
Page
44
of 58
May 27, 2011
3.4.5
Line Protector Mast Mounting Kit
The LP mast mount kit can be used to mount the surge protector device to a 51 to 177
mm (2 to 7 in) mast.
Note: The Polyphaser IX-PLMNT Pole-Kit kit is not available directly from Redline, and
must be ordered separately (if required) from a telecom equipment distributor.
1. Align assembly bracket (4) mounting holes with mounting holes at the bottom of the mounting
box.
2. Insert screws (3) through the mounting box, and assembly bracket (4) and secure with #8
flange nut (2).
3. Slide hose clamp (1) through both slotted grooves of bracket (4), secure hose clamp to mast.
Figure 33: Ethernet Surge Protection - Mast Mounting Kit
Table 13: Ethernet Line Protector - Mounting Kit Parts List
Item
Qty
Description
1
1
Metal Hose Clamp: 51 to 177 mm (2 to 7 in)
2
2
8-32 Hex HD Flange Nut 18-8 SS
3
2
8-32 Screw 3/4" Phillips Pan SS
4
1
Mounting Bracket Al