- 1 -
AN 80i Configuration Instructions
Страница 1: ... 1 AN 80i Configuration Instructions ...
Страница 2: ... Configuration Instructions AN80i For connections please refer to Figure 1 For the link distance of three meters and antenna gain of 9 or 15 dBi 10dB attenuator should be used on the client side Figure 1 ...
Страница 3: ...ss AN80i using GUI Open Internet Explorer and access AN80i Web page at IP address http 192 168 25 3 or http 192 168 25 2 IP address of each unit is given on the label attached to the unit Login using admin as User Name and Password Figure 3 Login ...
Страница 4: ...page menu select Configure System to set RF parameters The frequency can be set in steps of 2 5MHz Please note that antenna gain should be entered according to the antenna used After changes are done click on Save button at the bottom of the page ...
Страница 5: ... 5 Figure 5 Configure System ...
Страница 6: ... 6 Figure 6 Configure System continued TxOff or Chg Freq should be selected depending on the test performed When Chg Freq is selected Client should have Auto scan enabled ...
Страница 7: ... 7 The link status can be checked by selecting System Status from the Web page menu Figure 7 System Status ...
Страница 8: ...Password At the prompt type dbg dfs to enter DFS debug mode Commands available for testing purpose evtime Evaluation time 60 sec default value Should not be set less than 10sec resetevents To reset number of events detected txoffdis 1 or 0 To disable enable TxOff after radar detection txofftime To reduce TxOff time after radar detection In sec 1800 default value ...