background image

Содержание dld5x

Страница 1: ......

Страница 2: ...tempt to perform any internal servicing Repairs and service should be performed only authorised service centres of Redback Lasers This instrument complies with the safety Classification standards of laser radiation 2 CAUTION Class II laser 1mW at 635nm Do NOT stare into laser beam or aim at another person Follow relevant Australian Standards Copyright CMI LasersTM RedBack lasersTM and Level1Lasers...

Страница 3: ...for all types of indoor installation work whether its electricians transcribing points from floor to ceiling air conditioning installers windows and garage doors In fact this dot Line laser can just about do anything indoors Other features of the DLD5X include a sturdy magnetic base Tripod mounting options heavy duty construction with rubberised casing and Std AA Size battery operation The DLD5XTM...

Страница 4: ... Control Panel 2 Plumb Dot Up Laser Output 3 3x Horizontal Dots at 90o 4 Plumb Dot Down Laser Output 5 Screw to remove magnetic Base 6 Pendulum Lock Power On Off 7 Vertical Line Output 8 Horizontal Line Output 9 5 8 Survey Tripod Thread 9 ...

Страница 5: ... batteries to prevent any possible damage caused by leaking batteries Important never mix new and old batteries or batteries of different type e g Alkaline and Super heavy duty The DLD5X operates on 3 x standard AA batteries first remove the magnetic base from laser to expose underside locate battery compartment and pull latch to open battery compartment Insert batteries as indicated and close bat...

Страница 6: ... and ready to self level If the lasers flash together with a loud beeping sound then the DLD5XTM is out of self levelling range and the laser housing needs to be set up more level on the ground or tripod until the beeping stops the DLD5X is now in self levelling range The pendulum lock helps protect the laser level when not in use always store and transport your DLD5XTM with the lever in the Locke...

Страница 7: ...uds The DLD5X can also be mounted directly onto a camera style tripod utilising the same thread in the base of the laser that the magnetic base attaches to Once unlocked pressing the Line button will toggle between Horizontal Line Vertical LIne Both lines and lines off Pressing the Dot Button will toggle between Horizontal dots Plumb Up Down dots All dots and dots off The DLD5X has a manual mode i...

Страница 8: ... optional receiver with the lines in pulse mode Using with Optional Electronic Line Receiver The DLD5XTM can be used with an optional electronic Line receiver such as the RedBack LLR705 or LR200 To use a receiver the DLD5X needs to be switched into Pulse Mode by pressing the pulse button this makes lines visibly a little less bright but is required for the receiver to pick the lines up note dots c...

Страница 9: ...alia prior to despatch and should under normal conditions not go out of calibration A calibration certified sticker with the date and name of technician is located on the laser itself It is worth checking calibration from time to time particularly after any known knocks or drops An easy way to continually check calibration is to always double check you work with the laser located in a different po...

Страница 10: ...heck calibration from time to time See page 9 For service contact Redback Lasers www redbacklasers com au Q I hear a continuous beeping when turned on A This is the out of level alarm indicating that the DLD5XTM is outside of self levelling range re level the laser housing and try again Q The Laser does not power up A Check the pendulum lock has been unlocked rotated into the Unlock position Q The...

Страница 11: ...11 www redbacklasers com au Notes ...

Страница 12: ...s that our products will be free from defects in material and workmanship for the warranty period CMI promises to repair or replace free of charge the product or part of product if found to be faulty due to defective workmanship or materials within the duration of the warranty as long as the following terms and conditions are met Product must not have been misused or abused must not have incurred ...

Отзывы: