background image

Solar Regulator

SRPA0120 

SRPA0240 

SRPA0360

Содержание Solar SRPA0120

Страница 1: ...Solar Regulator SRPA0120 SRPA0240 SRPA0360 ...

Страница 2: ...regulator may result in overcharging the battery The solar panel s negative wire must be connected direct to the regulator only 4 Check the battery manufacturer s data for your battery and ensure that the voltage of the charging profile you select does not exceed the manufacturer s recommended maximum charging voltage If the Absorption voltage for your battery type is too high please select anothe...

Страница 3: ...inutes and seek medical assistance immediately 1 The Solar Regulator will achieve best results when proper battery maintenance is regularly performed This includes but is not limited to checking water and specific gravity levels of the battery CONTENTS The Solar Regulator 1 Warning Safety Instructions 1 Contents 2 1 Introduction 3 1 1 Dimensions 3 1 2 Regulator Function 3 2 The Solar Regulator 4 2...

Страница 4: ...o the AGM battery type setting A REDARC remote monitor SRPA RM is required to change the battery type 3 153 mm 98 mm SRPA0120 103mm SRPA0240 108mm SRPA0360 135 mm 28 mm Solar Panel Input Battery Output Solar Panel LED1 Indicator Battery LED2 Indicator RJ45 Remote Monitor Connector RJ45 Connector Cap ...

Страница 5: ...Orange Over temperature 4 LED1 flashing green 1 flash second The regulator is charging the battery and all functions are normal LED2 flashing green 1 flash second The battery is full and all functions are normal LED1 off There is no charge from the solar panel Check the solar panel is connected correctly and the panel is in full sunlight LED2 solid green The battery is connected and the voltage ra...

Страница 6: ...y Current Draw 10mA 4 5mA Battery Charging Limit Voltage 16V 32V Boost Reconnect Charging Voltage 13 2V 26 4V Power Rating 120W SRPA0120 240W SRPA0240 360W SRPA0360 240W SRPA0120 480W SRPA0240 720W SRPA0360 Current Limit 10A SRPA0120 20A SRPA0240 30A SRPA0360 Boost Charge 100 of available solar charge will be used until absorption voltage is reached Charge Type and Operating Frequency PWM 50Hz Cha...

Страница 7: ...e select another charging profile SRPA RM will be required to change from default setting Care should be taken to not expose the regulator to moisture For optimum operation the regulator should be mounted in an environment where the temperature is normally below 45 C and does not exceed 55 C Battery clip SRC0009 is intended for a portable short term connection and should not to be left connected p...

Страница 8: ...I style bolt down fuses as they ensure a low resistance connection The REDARC FK40 and FK60 fuse kits are recommended Blade type fuses are not recommended as they can result in high resistance connection which causes excess heat and may damage the fuse holder and or the wiring Self resetting circuit breakers are not recommended as they may trip prematurely due to the heat generated by the current ...

Страница 9: ...or By Default SRPA0120 SRPA0240 and SRPA0360 Regulators are set to AGM 3 3 2 REDARC CABLE RANGE Part Number Length Description SRC0007 10m Anderson to Anderson Cable SRC0008 1 5m Anderson to Anderson Cable SRC0009 1 5m Anderson to Battery Clip SRC0010 1 5m Anderson to Battery Terminal SRC0011 Series Anderson to Anderson Connector SRC0012 Parallel Anderson to Anderson Connector SRC0014 5m Anderson ...

Страница 10: ...4 SYSTEM WIRING 4 1 12V STANDARD SYSTEM 10m SRC0007 1 5m SRC0008 or 5m SRC0014 1 5m SRC0009 or SRC0010 Solar Regulator Optional Remote Monitor Solar Panel or Blanket 9 ...

Страница 11: ... SRC0008 or 5m SRC0014 Fuse Ratings Regulator Fuse Size SPRA0120 15A SPRA0240 SPRA0360 40A 30A Fuses are not supplied For other installations appropriate sized fuses must be used and should be determined according see Redarc FK40 Solar Regulator Optional Remote Monitor Solar Panels or Blankets in series 10 ...

Страница 12: ...or 5m SRC0014 SRC0012 Parallel Cable Fuse Ratings Regulator Fuse Size SPRA0120 15A SPRA0240 SPRA0360 40A 30A Fuses are not supplied For other installations appropriate sized fuses must be used and should be determined according see Redarc FK40 Solar Regulator Optional Remote Monitor Solar Panels in Parallel Fuse ...

Страница 13: ...5m SRC0008 or 5m SRC0014 SRC0012 Parallel Cable Fuse Ratings Regulator Fuse Size SPRA0120 15A SPRA0240 SPRA0360 40A 30A Fuses are not supplied For other installations appropriate sized fuses must be used and should be determined according see Redarc FK40 Solar Regulator Optional Remote Monitor Solar Panels in Parallel 12 ...

Страница 14: ...y Redarc that are designed for use in recreational vehicles and boats not otherwise specifically referred to in this clause 1 and 1 8 any component of or accessory for any product in clause 1 1 to 1 7 inclusive manufactured or supplied by Redarc Offer and duration of product warranties 2 Subject to this clause 2 Redarc warrants that its Solar Products will be free under normal application installa...

Страница 15: ... electrician or technician in accordance with the instructions of Redarc 11 If the Solar Product is found to be working satisfactorily on return to Redarc or upon investigation by Redarc the Purchaser must pay Redarc s reasonable costs of testing and investigating the Solar Product in addition to shipping and transportation charges Where Redarc is in possession of the Solar Product the Solar Produ...

Страница 16: ...meets the stringent quality levels of all REDARC products For free technical assistance please contact REDARC Electronics 23 Brodie Road North Lonsdale SA 08 8322 4848 power redarc com au www redarcsolar com au Copyright 2016 REDARC Electronics Pty Ltd All rights reserved This product is manufactured in China WARSOLARREG REV5 2016 Anderson Power Products Inc All rights reserved ...