background image

RS Series 12V Inverters

R-12-400RS-NA

Содержание R-12-400RS-NA

Страница 1: ...RS Series 12V Inverters R 12 400RS NA ...

Страница 2: ...ERFORMED IN ACCORDANCE WITH LOCAL AND NATIONAL CODES STANDARDS AND WIRING RULES INSTALLATION MUST BE PERFORMED BY QUALIFIED PERSONAL WHO MEET ALL LOCAL AND GOVERNMENTAL CODE REQUIREMENTS FOR LICENSING AND TRAINING FOR THE INSTALLATION MAINTENANCE AND CONNECTION OF ELECTRICAL POWER SYSTEMS SAFETY REGULATIONS RELEVANT TO THE INSTALLATION AND USE LOCATION SHALL BE FOLLOWED DURING INSTALLATION OPERATI...

Страница 3: ...ttery to explode 8 Batteries are capable of providing very large currents in the case of a short circuit A fuse must be installed on the positive supply cable as close as practical to the battery Failure to do so provides inadequate protection against fire in the case of a short circuit Only use high quality copper cable and keep the cable length short refer to Section 2 2 4 page 10 for more infor...

Страница 4: ...2 2 1 Chassis Ground 9 2 2 2 Remote Port RJ 11 9 2 2 3 Remote Control Green Terminal 9 2 2 4 DC Input Connection 10 3 INSTALLATION 11 3 1 Mounting 11 3 2 Ventilation Fan 12 3 3 Safety Before Installing DC Wiring Connections 12 3 3 1 Loads Are Disconnected 12 3 4 Check Cable and Fuse size 13 3 5 Chassis Ground Connection 13 3 6 DC Wiring Connections 14 3 7 AC Safety Grounding 14 3 8 Turning The Inv...

Страница 5: ...BAT Low Shutdown 10 5 0 3 VDC BAT Low Alarm 10 5 0 3 VDC BAT Low Restart 12 5 0 3 VDC BAT High Shutdown 16 0 0 3 VDC BAT High Alarm 16 0 0 3 VDC BAT High Restart 14 5 0 3 VDC Input Protection 2 Reverse Polarity Internal Fuse Others Over Under Temperature Protection by heat sink Temperature 176 F 80 C 4 F 20 C Environment Operating Temp 4 104 F Derates to 140 F 20 40 C Derates to 60 C Storage Temp ...

Страница 6: ...5 1 INTRODUCTION 1 2 Dimensions 5 91 150 mm 2 68 68 mm 1 41 35 7 mm 4 57 116 0 mm 0 87 22 mm 5 0 127 mm 5 36 136 2mm 7 36 187 mm RESET ...

Страница 7: ...rmance 200 1 Sec 1 Min Continue 115 110 0 Voltage V Power W 10 5V 16V Figure 1 3 1 400RS NA Voltage Performance 41 50 59 68 77 86 95 104 113 122 131 140 40 60 Temperature F C 11V Watt 500 400 300 200 100 0 Figure 1 3 2 400RS NA Temperature Performance ...

Страница 8: ... switch is for turning the AC mains output to either ON OFF or selecting the Remote mode When setting the power switch to the first ON position or the second ON position only to be used when operating the inverter through the REMOTE RS inverter remote the LEDs will glow GREEN After setting the power switch to the OFF position the inverter will stop and the LEDs will turn off 2 1 2 Function Switch ...

Страница 9: ...e over spec Red Red Red Red Red Red Check input voltage Reduce input voltage to meet inverter s specification Under Voltage Input DC voltage under spec 1 long beep 2 short beeps Red Red Red Check input voltage and recharge battery Check all input connections and cables Once input conditions are within specification try turning power switch off and on again Over Load 400 460 W VA 100 115 2 long bee...

Страница 10: ...is connection prior to any other connection 2 2 2 Remote Port RJ 11 The R 12 400RS NA inverter can be used with the REMOTE RS remote controls To enable use the main switch on the inverter must be set to the REMOTE position Pin Number Signal Description 1 1 Reserved 2 GND Same Polarity as Battery Negative 3 4 5 RMT Remote controller panel positive 6 2 2 3 Remote Control Green Terminal Pin Number Te...

Страница 11: ...le 2 2 4 1 The size of the cable should be thick enough to maintain a voltage drop of less than 2 when carrying the maximum input current This will help prevent frequent low input voltage warnings and shutdown The following sizes of cables and fuses are recommended for connection of the supply batteries to inverter see table 2 2 4 1 below for suitable cable sizing for your installation CAUTION BAT...

Страница 12: ... Close to batteries Avoid excessive cable runs between battery and inverter to reduce the voltage drop across the cable For safety reasons however even when installed in a well ventilated area the inverter should not be installed within 12 300 mm of the battery The inverter must never be installed within the same enclosed compartment with the battery 8 Use the recommended wire lengths and sizes se...

Страница 13: ... so may result in the inverter overheating and ultimately damage the inverter 3 3 Safety Before Installing DC Wiring Connections 3 3 1 Loads Are Disconnected Make sure all loads are disconnected from the inverter s AC output and ensure that the inverter main switch is set to the OFF position before connecting DC cables Figure 3 3 1 Ensuring loads are disconnected Figure 3 3 2 Switch is set to OFF ...

Страница 14: ... inverter or other appliances installed in the system 3 5 Chassis Ground Connection Connect Chassis Ground Terminal to the ground of vehicle this applies to all negative ground vehicles Chassis Ground must be connected to the ground of vehicle prior to making any other connections to the inverter CAUTION REVERSE POLARITY CONNECTION WILL BLOW THE INTERNAL FUSE AND MAY CAUSE PERMANENT DAMAGE TO THE ...

Страница 15: ...CONNECTIONS ARE TIGHT TORQUE TO 1 5 FT LBF 2 8 NM LOOSE CONNECTIONS COULD RESULT IN OVERHEATING AND CAN BE A POTENTIAL HAZARD DO NOT OPERATE THE INVERTER WITH DAMAGED OR SUBSTANDARD WIRING SELECTING THE WRONG CABLE OR FUSE SIZE COULD RESULT IN HARM TO THE INSTALLER OR USER AND OR DAMAGE TO THE INVERTER OR OTHER APPLIANCES INSTALLED IN THE SYSTEM THE INSTALLER IS RESPONSIBLE FOR ENSURING THAT THE C...

Страница 16: ...I socket s connect loads to the Inverter AC output Turn the inverter switch to ON Figure 3 8 1 Switching Inverter ON Figure 3 8 2 Correct Inverter Status 3 9 Connecting AC If all LEDs are green switch unit OFF it is safe for installer to plug the AC cord s into the GFCI socket s connect loads to the Inverter AC output Turn the inverter switch to ON 3 10 Maintenance Turn the unit OFF before cleanin...

Страница 17: ... radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourag...

Страница 18: ...mithfield NC 27577 Australia and New Zealand www redarc com au power redarc com au REDARC Electronics Pty Ltd 23 Brodie Road North Lonsdale SA 51600 Australia USA 1 704 247 5150 Canada 1 604 260 5512 Mexico 52 558 526 2898 Australia 1300 REDARC 1300 733 272 New Zealand 64 9 222 1024 UK and Europe 44 0 20 3930 8109 Design and specifications are subject to change without notice Copyright 2021 REDARC...

Страница 19: ...18 NOTES ...

Страница 20: ...3 North America power redarcelectronics com www redarcelectronics com Australia and other Global regions power redarc com au www redarc com au 1300 REDARC 1300 733 272 New Zealand power redarcelectronics co nz www redarcelectronics co nz 64 9 222 1024 United States 1 704 247 5150 Canada 1 604 260 5512 Mexico 52 558 526 2898 UK Europe power redarcelectronics eu www redarcelectronics eu 44 0 20 3930...

Отзывы: