background image

RS Series 12V & 24V Inverters

(350W model)

Содержание 350W

Страница 1: ...RS Series 12V 24V Inverters 350W model ...

Страница 2: ...IONS INSTALL ACCORDING TO APPROPRIATE AS NZS STANDARD 4 RISK OF ELECTRICAL SHOCK BEFORE PROCEEDING CAREFULLY CHECK THAT THE INVERTER IS NOT CONNECTED TO ANY BATTERIES AND THAT ALL WIRING IS DISCONNECTED FROM ANY ELECTRICAL SOURCES 5 DO NOT CONNECT THE OUTPUT TERMINALS OF THE INVERTER TO AN INCOMING AC SOURCE 1 This appliance is not intended for use by persons including children with reduced physic...

Страница 3: ...y you purchased this unit from 2 Install the inverter in a well ventilated area with reasonable clearance Do not install the inverter in a zero clearance compartment or obstruct the ventilation openings Doing so may result in the inverter overheating and ultimately damage the inverter 3 Depending on the user scenario the AC output of the inverter may require a user installed breaker or fuse In an ...

Страница 4: ...tch 07 1 Function Switch 07 1 Output Voltage 07 2 Output Frequency 07 3 Power Saving 07 2 LED Indication 08 2 Rear Panel Operation 09 1 Remote Port RJ11 09 2 Remote Control Green Terminal 09 3 Chassis Ground 09 4 DC Input Connection 10 3 Protection Features 10 3 Installation 11 1 Mounting 11 2 Ventilation Fan 11 3 DC Wiring Connections 12 4 AC Safety Grounding 13 5 Maintenance 13 4 Two Year Produc...

Страница 5: ...Terminal Set Main Switch to ON 6 Switch the Inverter Main Switch to the ON position Connect DC Cables 3 Connect the DC cables to the Inverters DC Input Terminals Check cable and fuse size Refer section 2 2 4 4 Ensure that the cable is of adequate size and is protected by the correct sized fuse Switch OFF and connect AC loads 7 If the LED is Green switch unit off connect loads to the Inverter AC Ou...

Страница 6: ...attery Low Alarm 10 5V 0 25V 21V 0 5V Battery Low Restart 12V 0 25V 24V 0 5V Battery High Alarm 15V 0 25V 30V 0 5V Battery High Shutdown 15 5V 0 25V 31V 0 5V Battery High Restart 14 5V 0 25V 29V 0 5V Protections Overload Short Circuit DC Over or Under Voltage Over Temp Working Temperature 20 C 50 C Derates to 60 C Storage Temperature 30 C 70 C Working Humidity Max 90 RH non condensing Safety EMC C...

Страница 7: ...6 1 INTRODUCTION 1 3 Dimensions 150 5 91 68 2 68 35 7 1 41 116 0 4 57 22 0 87 127 5 00 187 7 36 ...

Страница 8: ...1 Main Switch The 3 stage switch is for turning ON or OFF and selecting Remote mode Set the power switch to the ON position The inverter will perform self diagnosis and the LEDs will display various colours Set the power switch to the OFF position The inverter will stop and all LEDs will turn off 2 1 2 Function Switch Power saving Output frequency and Output voltage settings can be controlled usin...

Страница 9: ...er 30 seconds and restart 4 times Red Output Short Circuit Shutdown after 2 seconds and restart 4 times Red Over Temperature Red Red Red Red Shutdown High Battery Red Red Red Red Red Red High Battery Orange Orange Orange Orange Orange Orange Low Battery 5 short beeps every 15 sec Orange Orange Orange Shutdown Low Battery Red Red Red 2 2 Rear panel operation A B D C ...

Страница 10: ... Enable ENB 3 Enable ENB Before Installing Make sure that the inverter main switch is at OFF position Before using the remote function make sure the main switch is set to REMOTE Use 20 24AWG cable to connect the remote control terminals 2 2 3 Chassis Ground Always connect chassis ground to battery negative Use 1 5mm or more RISK OF ELECTRICAL SHOCK OPERATION OF THE INVERTER WITHOUT A PROPER GROUND...

Страница 11: ...nals are used refer to table 2 2 4 2 below for suitable lug size with reference to your chosen cable size Table 2 2 4 1 Recommended Cable Fuse Sizing Cable Length 12V Models 24V Models Cable Size mm AWG Inline Fuse Rating A Midi Cable Size mm AWG Inline Fuse Rating A Midi 0 1m 13 6 50 6 10 30 1 2m 13 6 50 6 10 30 2 3m 21 4 50 8 8 30 3 4m 27 3 50 8 8 30 4 5m x x 13 6 30 5 6m x x 13 6 30 Fuse rating...

Страница 12: ...xcessive cable lengths however the unit should not be installed within 300mm or in the same compartment as a battery 8 Use the recommended wire lengths and sizes see section 2 2 4 9 Do not mount the inverter where it will be exposed to the gasses produced by the battery These gasses are very corrosive and prolonged exposure will damage the inverter RISK OF ELECTRICAL SHOCK DO NOT EXPOSE THE INVERT...

Страница 13: ...oltage warnings and shutdowns As the supply cable increases in length or reduces in size gets narrower the voltage drop will increase Batteries are capable of providing very large currents in the case of a short circuit A fuse must be installed on the positive supply cable as close as practical to the battery Failure to do so provides inadequate protection against fire in the case of a short circu...

Страница 14: ...rding to the instructions in this manual are categorised as EPB inverters Neither active nor neutral is referenced to ground and or chassis within the inverter An RCD will not trip when used with this inverter unless a MEN neutral to earth connection is implemented before the RCD External connection of such should be determined as appropriate or not by the licenced electrician The AC output ground...

Страница 15: ...he control of REDARC 7 Warranty claims in respect of a Product must be made in writing to REDARC at the postal address or email address specified in clause 21 within the Warranty Period Such claims must include the following 7 1 details of the alleged defect or fault and the circumstances surrounding the defect or fault 7 2 evidence of the claim including photographs of the Product where the subje...

Страница 16: ...ase contact REDARC Electronics 23 Brodie Road North Lonsdale SA 08 8322 4848 power redarc com au www redarc com au Copyright 2017 REDARC Electronics Pty Ltd All rights reserved MADE IN CHINA www redarc com au WAR350RSInverters REV7 ...