Pub. 42004-545A
telephone VoIP WiFi Telephone Manual
Page 9 of 29
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-545A.docx
03/20
Models 393-810A, 393AL-810A, and 394AL-812A (Surface Mount
Applications)
1.
Remove the four security screws from the
front panel.
2.
Position the enclosure on the mounting
surface.
The enclosure provides four 0.28-inch
mounting holes in a 7.0
×
8.5-inch hole
pattern.
3.
Secure the enclosure to its mounting surface
with four ¼-inch diameter bolts of the
appropriate length for the surface.
N
OTES
:
•
When using the GAI-Tronics Model
231-001 Pole Mounting Kit, follow the
mounting instructions provided in the
kit.
•
When mounting outdoors, installation of
a (customer-supplied) surge suppresser
on the power line is recommended.
4.
Model 393-810A only
: Create a conduit
access hole using a hole punch equivalent in size to the conduit diameter. Bottom entry is strongly
recommended. Insert a conduit fitting in the access hole.
5.
Install conduit as required (see the Conduit Installation (Surface-Mount Models) section on Page 8).
N
OTE
:
Use silicone sealant or equivalent around and inside all conduit entries.
6.
Pull the power and ground cable through the conduit and terminate the cable (see the Field Wiring
section on Page 14).
N
OTE
:
If mounted outdoors, the installation of a (customer-supplied) surge suppressor on the power
line is recommended.
7.
Connect any desired peripheral devices (see the Auxiliary I/O section on Page 16).
8.
Perform the initial programming of the telephone (see the Programming section on Page 17).
9.
Verify operation by calling to and from another telephone.
10.
Attach the front panel assembly to the rear enclosure using the four security screws.
11.
Torque the screws to 10–12 in·lb.
Figure 5. Model 393-810A VoIP Telephone in a
Non-metallic Enclosure