In the event all CAT5e patch cables are short (i.e. All Ethernet devices are located in the same local cabinet and/or
referenced to the same earth ground), it is permissible to use fully shielded cables terminated to chassis ground at
both ends in systems avoid low level analog signals.
RJ45
Connector
Crimp
Specifications
2.8
NTCD
‐
CFG
Configuration
Device
Warning/Avertissement:
•
Do not use, connect, or disconnect unless the area is known to be non-hazardous. Connection or disconnection
in an explosive atmosphere could result in an explosion.
•
Ne pas utiliser, de connecter ou déconnecter sauf si la zone est connue pour être non dangereuse. Connexion
ou la déconnexion dans une atmosphère explosive pourrait entraîner une explosion.
NTCD-CFG-M12
NTCD-CFG
Configuration Device
Ideal for saving or restoring switch configuration
parameters quickly without the need for a computer
or software. One configuration device per switch is
recommended.