N-Tron
®
Series 1000
Unmanaged Gigabit Industrial
Mid-Span POE Injectors
Hardware Guide |
August 2016
Страница 1: ...N Tron Series 1000 Unmanaged Gigabit Industrial Mid Span POE Injectors Hardware Guide August 2016 ...
Страница 2: ...particular purpose In no event shall Red Lion be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits arising out of errors or omissions in this manual or the information contained herein CONTACT INFORMATION AMERICAS Inside US 1 877 432 9908 Outside US 1 717 767 6511 Hours 8am 6pm Eastern Standard Time UTC GMT 5 hours ASIA PACIFIC ...
Страница 3: ...es iv Publication History iv Related Documents iv Document Comments iv Additional Product Information iv Warnings and Cautions iv General Safety Cautions and Warnings v Electrical Safety Warnings v Environmental Safety Cautions and Warnings vi Introduction and Specifications Introduction 1 1 1000 POE 1 1 Key Features 1 1 Key Specifications 1 2 Dimensions 1 3 Regulatory Approvals 1 4 Product Orderi...
Страница 4: ... Connections 2 11 Power Connection Top View 2 11 Grounding Techniques for 1000 Series 2 11 RJ45 Connector Crimp Specifications 2 13 Typical Application 2 13 Connecting the Unit 2 14 Operation and Maintenance Introduction 3 15 Controls and Indicators 3 15 Maintenance 3 16 Verify Troubleshoot Cable Interface 3 16 Cleaning 3 16 Red Lion Controls N Tron 1000 Series Limited Warranty 3 17 ...
Страница 5: ...a Class A digital device as described in the FCC Rules This product complies with Part 15 of the FCC A Rules Operation is subject to the following conditions 1 This device may not cause harmful Interference 2 This device must accept any interference received including interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A di...
Страница 6: ...hanges The latest online version of this document and all product updates can be accessed through the Red Lion web site at http www redlion net documentation Publication History The following information lists the release history of this document Related Documents Visit the Technical Resources page on the Red Lion website at the following link to view available documents related to this product ht...
Страница 7: ...el WARNING Install only in accordance with Local and National Codes of authorities having jurisdiction ALERTE Installer uniquement conformément aux codes locaux et nationaux des autorités ayant compétence Electrical Safety Warnings WARNING Do not work on equipment or cables during periods of lightning activity ALERTE Ne pas travailler sur le matériel ou les câbles pendant les périodes d activité d...
Страница 8: ...ng power input cables Reversing voltage polarity can cause permanent damage to the unit and voids the warranty ATTENTION Respecter la polarité correcte de tension DC lors de l installation des câbles d alimentation d entrée Inversion de polarité de tension peut causer des dommages permanents à l appareil et annule la garantie vi N Tron Series Unmanaged Gigabit Industrial Mid Span PoE Injector Hard...
Страница 9: ...r 5 minutes avant de la toucher WARNING These products are open type devices and are meant to be installed in an enclosure suitable for the environment this is only accessible with the use of a tool in accordance with the National Electrical Code NEC NFPA 70 ALERTE Ces produits sont des appareils de type ouvert et sont destinés à être installés dans un boîtier adapté à l environnement ce n est acc...
Страница 10: ...viii N Tron Series Unmanaged Gigabit Industrial Mid Span PoE Injector Hardware Guide Revised 2016 8 30 Preface Drawing No LP0986 ...
Страница 11: ...ned to provide Power over Ethernet for PoE capable devices where running a power line is either not possible or not cost effective This feature allows an end user to power a PoE camera wireless access point or any other PoE capable device without the need for running separate wires for power This also allows the ability for a centralized battery backup for all connected devices Key Features Compac...
Страница 12: ... Rail 35 mm BTU HR 13 POWER OVER ETHERNET PoE Standard IEEE 802 3af at Gigabit Mid Span PSE PoE Output Power 54 VDC 30W 25 5W at PD Power Pin assignment Pins 4 5 Pins 7 8 PSE Type Type 2 ENVIRONMENTAL NETWORK MEDIA Operating Temperature 40 C to 80 C 10BaseT Cat 3 Cable Storage Temperature 40 C to 85 C 100BaseT Cat 5 Cable Operating Humidity 10 to 95 Non Condensing 1000BaseT Cat 5e Cable Operating ...
Страница 13: ...N Tron Series Unmanaged Gigabit Industrial Mid Span PoE Injector Hardware Guide 1 3 Introduction and Specifications Revised 2016 08 30 Dimensions Drawing No LP0986 Dimensions ...
Страница 14: ...atory Approvals Safety For use in Class I Division 2 Groups A B C and D Hazardous Locations UL 508 Industrial Control Equipment ANSI ISA 12 12 01 2007 for use in Class I and II Division 2 and Class III Divisions 1 and 2 Hazardous Classified Locations Groups A B C D T4A cUL C22 2 No 14 M05 cUL C22 2 No 213 M1987 for use in Class I Division 2 Hazardous Locations EMI EN61000 6 4 EN55011 Class A FCC T...
Страница 15: ... running separate wires for power This also allows the ability for a centralized battery backup for all connected devices Key Features Compact Space Saving Package Full IEEE 802 3 af at Compliance Four 10 100 1000Base T RJ 45 Ports DATA IN Four 10 100 1000Base T RJ 45 PoE Ports DATA POWER OUT Unmanaged Plug and Play Operation Extended Environmental Specifications 40 C to 85 C Operating Temperature...
Страница 16: ...35 mm BTU HR 40 POWER OVER ETHERNET PoE Standard IEEE 802 3af at Gigabit Mid Span PSE PoE Output Power 57VDC 30W 25 5W at PD per port Power Pin assignment Pins 1 2 Pins 3 6 PSE Type Type 2 ENVIRONMENTAL NETWORK MEDIA Operating Temperature 40 C to 85 C 10BaseT Cat 3 Cable Storage Temperature 40 C to 85 C 100BaseT Cat 5 Cable Operating Humidity 10 to 95 Non Condensing 1000BaseT Cat 5e Cable Operatin...
Страница 17: ...N Tron Series Unmanaged Gigabit Industrial Mid Span PoE Injector Hardware Guide 1 7 Introduction and Specifications Revised 2016 08 30 Dimensions Drawing No LP0986 Dimensions ...
Страница 18: ...mp Regulatory Approvals Safety ANSI ISA 12 12 01 2015 Class I and II Div 2 and Class III Div 1 and 2 Groups A B C and D Hazardous Locations T4 UL508 Industrial Control Equipment CAN CSA C22 2 No 213 15 Hazardous Locations CAN CSA C22 2 No 14 13 Industrial Control Equipment EMI FCC Title 47 Part 15 Radio Frequency Devices Subpart B ANSI C63 4 2009 Industry Canada ICES 003 EN 55032 EN 61000 3 2 EN61...
Страница 19: ...in undamaged condition 1 N Tron Series Unmanaged Gigabit Industrial Mid Span PoE Injector 2 Instruction Sheet If the package contents are damaged 1 Contact your carrier 2 File any damage claims with the carrier Installing Mounting Read the following warning before beginning the installation Lire l avertissement suivant avant de commencer l installation WARNING Never install or work on electrical e...
Страница 20: ... Rack Mount Kit P N URMK can be used to mount the POE injectors enclosures to standard 19 racks and our Panel Mount Assembly P N 1000 PM can be used to mount the 1000 Series enclosures to a panel or any other flat surface The 1000 POE4 will require the 1K26 PMK panel mount b To install the unit to 35mm industrial DIN Rail place the top edge of the included mounting bracket on the back of the unit ...
Страница 21: ... que l alimentation en courant continu est appliquée peut provoquer des étincelles et endommager le connecteur d entrée de façon permanente Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation V1 and V2 plugs must be connected to separate DC Voltage sources Use wire sizes of 16 10 gauge The power cord should be limited to less than 3 meters in order to...
Страница 22: ...an alternative grounding method both V legs of the power input connector are connected to chassis internally on the PCB Connecting a drain wire to earth ground from one of the V terminal plugs as shown here will ground the switch and the chassis The power leads from the power source should be limited to 3 meters or less in length Note The 1000 POE4 power input V pins are isolated from chassis grou...
Страница 23: ...RJ45 Connector Crimp Specifications 2 13 N Tron Series Unmanaged Gigabit Industrial Mid Span PoE Injector Hardware Guide RJ45 Connector Crimp Specifications Please reference the illustration below for your Cat5 cable specifications Typical Application ...
Страница 24: ...RJ45 connector Connect the other end to the far end station The total length of cable should not exceed 100 meters Although power is being applied to the Ethernet port the power does not boost data on the lines CAUTION Creating a port to port connection on the same injector i e loop is an illegal operation and will create a broadcast storm which will crash the network ATTENTION Création d un port ...
Страница 25: ...uction Drawing No LP0986 Section 3 Operation and Maintenance Introduction The N Tron Series Unmanaged Gigabit Industrial Mid Span PoE Injectors provide operating status information through the LED indicators located on their front panels Controls and Indicators Front Panels From Top to Bottom V1 V1 Power LED V2 V2 Power LED Power Supply ...
Страница 26: ...e LED Green PoE power is being applied to the corresponding port OFF No PoE Power is applied to the corresponding port Maintenance Maintenance is limited to verifying the cable interface and unit cleaning Verify Troubleshoot Cable Interface 1 Make sure either V1 or V2 Power LED is Green 2 Make sure you are supplying sufficient current for the 1000 POE 1000 POE4 and all the powered devices plugged ...
Страница 27: ... BY LAW COURSE OF DEALING COURSE OF PERFORMANCE USAGE OF TRADE OR OTHERWISE Customer shall be responsible for determining that a Product is suitable for Customer s use and that such use complies with any applicable local state or federal law b The Company shall not be liable for a breach of the warranty set forth in paragraph a if i the defect is a result of Customer s failure to store install com...