background image

DESCRIPTION

The CUB7P is an 8-digit miniature programmable counter with large 0.35

inch (8.90 mm) high digits. It has an LCD read-out available in Positive Image
Reflective, Negative Image Transmissive with yellow/green backlighting, or red
backlighting. Backlight units require an external 9 to 28 VDC power supply. 

The CUB7P is available in either Low Speed Contact, High Speed Logic or

Voltage versions. The Contact versions (CUB7P0xxx) operate from a switch
contact or an NPN open collector transistor. The Logic versions (CUB7P2xx)
operate from 3 VDC logic output or from an NPN open collector transistor. The
Voltage versions (CUB7P1xxx) operate from a signal voltage of 10 to 300 V
(AC 50/60 Hz or DC).

The CUB7P has a programmable prescaler that can be set for any value

between 0.0001 and 1.9999. The decimal point position can be set anywhere
from 0 (no D.P.) to 0.000000 or no Leading Zero Blanking. Both the prescaler
and DP selection are accessed using the front panel PGM and RESET push
buttons. See Programming for details. Note that the count, prescaler and DP
values will be lost if the battery is removed. See BATTERY INSTALLATION
for additional information.

The CUB7P counters use a CMOS LSI chip, mounted on a gold-plated

substrate, that is electrically connected by ultrasonic wire-bonding. Proven
micro-electronic assembly and manufacturing techniques provide these units
with the reliability and dependability required for industrial service.

The CUB7P series is housed in a lightweight, high impact plastic case with a

clear viewing window. The sealed front panel with the silicone rubber buttons
meets NEMA 4X/IP65 specifications for wash-down and/or dusty
environments, when properly installed.

SAFETY SUMMARY

All instructions that appear in the bulletin or on equipment, all safety related

regulations, and all local codes must be observed to ensure personal safety and
to prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

CAUTION: Read complete

instructions prior to installation

and operation of the unit.

CAUTION: Risk of electric shock.

1

!

3 (8 Digit 0.35") LCD DISPLAY OPTIONS (Reflective, Red

Transmissive, Yellow/Green Transmissive. 9 to 28 VDC power
supply required for versions w/ LED backlighting)

!

AVAILABLE WITH LOW SPEED CONTACT (30 Hz MAX.), HIGH

SPEED LOGIC (10 KHz MAX.) OR VOLTAGE INPUTS (10 TO 300
VAC/DC)

!

PRESCALER FROM 0.0001 TO 1.9999

!

SELECTABLE DECIMAL POINTS

!

REPLACEABLE INTERNAL LITHIUM BATTERY PROVIDES UP

TO 6 YEARS OF UNINTERRUPTED OPERATION (Battery Included)

!

WIRE CONNECTIONS VIA SCREW CLAMP TYPE TERMINALS

!

FRONT PANEL AND REMOTE RESET INPUT

!

NEMA 4X/IP65 SEALED FRONT BEZEL

MODEL CUB7P PROGRAMMABLE  ELECTRONIC 8-DIGIT COUNTER

DIMENSIONS  In inches (mm)

Note: Recommended minimum clearance (behind the panel) for mounting clip installation

is 2.1" (53.4) H x 5.5" (140) W.

PANEL CUT-OUT

Bulletin No.  CUB7P-B
Drawing No.  LP0441
Released  5/02

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion-controls.com

!

BOTH FRONT PANEL PROGRAM AND RESET BUTTONS ARE

INDIVIDUALLY ENABLED

AUDIN - 8, avenue de la malle - 51370 Saint Brice Courcelles - Tel : 03.26.04.20.21 - Fax : 03.26.04.28.20 - Web : http: www.audin.fr - Email : [email protected]

Содержание CUB7P0

Страница 1: ...r viewing window The sealed front panel with the silicone rubber buttons meets NEMA 4X IP65 specifications for wash down and or dusty environments when properly installed SAFETY SUMMARY All instructio...

Страница 2: ...AL INPUT LS terminal 4 See Count Edge under Programming for incrementing edge of input signal Contact Input CUB7P0xx 30 Hz max from Switch Contact or solid state Transistor Switch to Common witha50 du...

Страница 3: ...ble to the unit to suppress power line interference Install them near the power entry point of the enclosure The following EMI suppression devices or equivalent are recommended Ferrite Suppression Cor...

Страница 4: ...d to be mounted into an enclosed panel The viewing window and reset button are factory sealed for a washdown environment A sponge rubber gasket and mounting clip are provided for installing the unit i...

Страница 5: ...en the LS input and Common Any off state leakage current may prevent the counter from operating properly WARNING If voltage input is connected to circuits above 30 Vrms any lead may be at hazardous li...

Страница 6: ...put voltage the neutral of the single phase AC signal is connected to Terminal 1 COM and line hot is connected to Terminal 4 LS The DC supply for the backlighting is connected as shown in the drawing...

Страница 7: ...ctive Counter w Red Backlighting Counter w Yel Grn Backlighting Counter Positive Image Reflective PART NUMBER CUB7P000 CUB7P010 CUB7P020 CUB7P100 CUB7P110 CUB7P120 CUB7P200 CUB7P210 CUB7P220 BNL10000...

Страница 8: ...armless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal...

Отзывы: