BAL_FlowControl_EN_1V3_REC_121-006454644
5.8
BDE-D FC Menu
BDE-D FC Menu
Menu item
Default
Description
Select the Manager authorisation level
Parameters > Counting
Press key sequence (double-click)
Max. no people
10
Setting the maximum number of persons allowed
Parameters > Signalisation
Door control
ON
ON = door is automatically deactivated when the person
limit is reached
From Software version 2.3.0
LED output
ON
ON = LED on in counting
mode
OFF = LED off in counting
mode
parameters
Menu
statistics
counting
max. no. people
state
signalisation
door Contr.
LED output
LED blinking
blink duration
blink interval
voice output
repeat delay
repeat delay ok
%-Alarm 1
%-Alarm 2
%-Alarm 3
BDE-D FC
brightness
contrast
total cnt.
cnt. log
reset cnt.
status
LED blinking
OFF
ON = LEDs flash red when the counter reaches the set limit.
Blink duration
5 s
Duration of how long the LEDs flash. After that, continuous
light.
Blink Interval
500 ms
Flashing frequency (speed of flashing)
Voice output
ON
ON/OFF Voice output
Repeat Pause
30 s
Pause time of voice output message 1 (if max. pers.
reached)
Repeat Pause OK
0 s
Pause time for voice output message 2 (if max. pers. is un-
derrun)
% Alarm X
100%
Output switches depending on the current counter reading
to max. number of persons
Parameters > BDE-D FC
Brightness
60%
Adjusting the brightness of the display
Contrast
40%
Setting the display contrast
Statistics
Total counter
n/a
Continuously detects all passes in the direction of entry
Counter log
n/a
Records all counts in the direction of entry per usage (max.
15 entries), switching off the machine creates a new entry
Reset counter
n/a
Total counter and log counter are reset to 0
Status
Status
n/a
Display of active status information