3
Description
14 / 28
BAL_FlowControl_EN_1V3_REC_121-006454644
Engineer - Available settings
– Number of doors being monitored
– Sensor CAN bus addresses
– Sensor settings (Sensitivity, Sensor field boundaries, Object height, Sensor height)
– Language
– Show software version
3.5
Count data analysis and data transfer (optional)
Data-Box (optional) - Available settings
– With optional 2G/3G/4G/Wi-Fi interface
– Current number of people in store
– Current setting for MAX allowable people in store
– Total number of people who entered store (incl. and excl. manual adjustments made to count)
– Total number of people who left store (incl. and excl. manual adjustments made to count))
– + Manual adjustments made to count
– - Manual adjustments made to count
NOTICE
Remote Data: All data is live, currently updated once every 30 seconds
3.6
Operating modes
Display
Operating mode
Function
Status
002 / 050
OFF
Counting
– Inactive
LED displays
– Inactive
Interaction with door
– Inactive
Current counter
value
– Current counter value is set to zero
002 / 050
EXIT ONLY
Counting
– Active
LED displays
– Red
Interaction with door
– Exit only. Entrance radar inactive
002 / 050
COUNTING
Counting
– Active
LED displays
– Green, when the maximum number of persons is
reached: Red.
Interaction with door
– When max. number of persons reached: Only exit,
entrance radar inactive.
NOTICE
During system start-up, the counting is inactive, the LED displays are off and there is no inter-
action with the door. After initialization, the OFF mode is activated and the system is ready for
operation.