Requirement
Quantity
Rotary hammer drill
1
11/16 Masonry Bit
1
Vacuum
1
Chemical Anchor (We recommend Hilti HVU2 or Hilti HY 200 R.)
-
½"-13 threaded rod, cut to 12"
4
½-13 locking nuts
4
Heavy gauge washers
4
Marker
1
Concrete punch
1
Adjustable torque wrench
1
Forge/Station mounting template (located in mailing tube in crate)
1
WARNING:
When using a rotary hammer drill or a chemical anchor, ensure that the
operator is trained and understands the manufacturer's warnings and best practices.
Mounting procedure
Use your marker to roughly mark the hole pattern of the four mounting holes located at the base of the
stand. This can be done easily by sliding one of your rods through each mounting hole and tracing its
outline on the floor. We will be making additional, more exact markings in the next step.