background image

Tap

Add Device

to open the Device Library.

2

In the Device Library list, select

Yaskawa Motoman industrial robot

. Then tap

NEXT

.

3

VERSION 1.0.0

© 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED

30

Содержание Forgelos5

Страница 1: ...Yaskawa YRC1000micro Startup Guide...

Страница 2: ...by themselves a fully integrated workcell As required in ISO 10218 2 READY Robotics strongly recommends performing a complete risk assessment of the integrated workcell per ISO 12100 You may wish to u...

Страница 3: ...ing The YRC1000 And Forge OS Through Ethernet 14 Setting Up Forge OS 15 Getting Robot Files From Forge OS 29 Changing Yaskawa Motoman Settings To Prepare For Forge OS 33 Transferring Configuration Fil...

Страница 4: ...to your Forge hub and Yaskawa controller 3 Connect the Yaskawa controller to your Forge hub 4 Power up 5 Make changes to the robot safety and communication settings on the Yaskawa pendant 6 Install a...

Страница 5: ...REFERENCE Note The default Safety Mode password for Non Collaborative robots 5555 5555 5555 5555 Note For Collaborative robots refer to the 16 digit password in the Collaborative Robot Password Agree...

Страница 6: ...s for more information We recommend using an empty USB storage drive with at least 2 GB of storage With the controller powered off insert the USB drive into the back of the Yaskawa Motoman programming...

Страница 7: ...have a gray side menu on the left hand side of the screen VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED 7...

Страница 8: ...s on the pendant to find and highlight EX MEMORY in the menu list Select SAVE 5 Scroll down to highlight SYSTEM BACKUP CMOS BIN then press SELECT 6 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGH...

Страница 9: ...er 9 Remove the USB drive from the pendant 10 Keep your USB backup drive in a secure location You can save the backup files from the USB onto a workstation 11 Install the Yaskawa software version YBS2...

Страница 10: ...t purchase the controller with optional Functional Safety Unit Expansion parts or if you find the parts missing please contact Yaskawa Motoman Robotics to order the parts listed below and receive inst...

Страница 11: ...READY Robotics for the correct startup guide A Forge hub Device YRC1000micro Controller KEBA pendant Electric Shock Warning Disconnect all components from power sources before attempting this installa...

Страница 12: ...tch Circuit 1 24 White Pink Key Switch Circuit 1 22 White Key Switch Circuit 2 20 Blue Key Switch Circuit 2 18 White Blue Not Connected Connect the KEBA pendant s Ethernet connector to the Forge hub P...

Страница 13: ...ncing Connect fence channel 1 to connector pins 61 and 63 1 Connect fence channel 2 to connector pins 65 and 67 2 3 If you are not using external safety fencing Bridge the FSU I O Breakout pins 61 and...

Страница 14: ...thernet cable Route Ethernet cabling from the Forge hub to the Yaskawa controller 1 Connect one end of the Ethernet cable to the LAN port on the back of the YRC1000micro 2 Plug the other end of the Et...

Страница 15: ...ller into the computer Note If you do not have enough USB ports on your computer for all of these devices use a USB hub 2 Turn on or restart the Forge hub and press the key on the keyboard that opens...

Страница 16: ...Select your language Then click Install Forge 6 Choose a keyboard layout Then click Continue 7 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED 16...

Страница 17: ...n click Continue 8 Select Erase disk and install forgeos Then click Install Now Note If Forge OS is already installed the installation wizard may prompt you with additional options The current goal is...

Страница 18: ...erase the entire disk by clicking Continue 10 If you are installing on a Forge Ctrl check the checkbox labeled This hardware is a Forge CTRL Click Continue 11 VERSION 1 0 0 2021 COPYRIGHT READY Roboti...

Страница 19: ...rk Pick a username and password and then click Continue Note The username and password that you create here are for accessing the Forge hub computer on a monitor other than the KEBA pendant They are N...

Страница 20: ...Wait for the installation to complete 14 Once the installation completes click Restart Now 15 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED 20...

Страница 21: ...installer Unplug the USB installer from your computer and press the Enter key on your keyboard 16 You will see a black screen with the Forge OS 5 logo Wait for Forge OS to finish booting up 17 VERSION...

Страница 22: ...y to run on the KEBA pendant Disconnect the monitor keyboard and mouse that you used to install Forge OS 18 On the KEBA pendant tap PAIR PENDANT Note The blue PAIR PENDANT button may take some time to...

Страница 23: ...irected to the Settings app until you activate a valid user license 4 Find another USB drive to use for Forge OS license activation Note Contact READY Robotics for your license code You can use any US...

Страница 24: ...USB Drive when prompted 4 Remove the USB from your Forge hub 5 6 Import the activation certificate and create the unlock certificate Insert the USB into your PC 1 Find the USB in your PC file explorer...

Страница 25: ...tivate 4 The portal generates new text characters Copy all of the text and paste it in the empty Forge_OS License Unlock Certificate txt file 5 Save the unlock certificate file 6 Remove the USB from y...

Страница 26: ...om a USB drive you can do that through the System Update screen Note Contact READY Robotics for an update file Update files are too large for the FAT32 file format Use an exFAT or NTFS formatted USB d...

Страница 27: ...w under Available Versions tap the version to install 3 Wait for the update to finish and restart Forge OS using the power button at the bottom of the screen 4 You can change system preferences from t...

Страница 28: ...and Date settings or the Admin login password Note If you later forget what you change your password to contact READY Robotics to reset it 2 Tap SAVE to save changes and exit the General Settings men...

Страница 29: ...will start to add the robot in Forge OS and get the robot files to put onto the robot controller In the Admin role tap the Device Configuration icon to open the Device Configuration app 1 VERSION 1 0...

Страница 30: ...Tap Add Device to open the Device Library 2 In the Device Library list select Yaskawa Motoman industrial robot Then tap NEXT 3 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED 30...

Страница 31: ...u are using a force sensor device select it from the dropdown 4 Insert a USB flash drive into the Forge hub as instructed on the screen Use an empty flash drive with at least 2GB of storage 5 Tap Star...

Страница 32: ...Insert the USB into the Motoman programming pendant USB port 8 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED 32...

Страница 33: ...are only required if this is your first time setting up Forge OS or if your Yaskawa controller has been factory reset On the Motoman pendant turn the key to the TEACH position fully counter clockwise...

Страница 34: ...e drop down list and press the SELECT button on the pendant keypad 3 Enter the Safety Mode password and press ENTER 4 If successful the visible mode will change to SAFETY MODE If an incorrect password...

Страница 35: ...FSU and press the SELECT button to set it to INVALID 4 Power off the YRC1000 controller and wait 10 seconds 5 Press and hold the MAIN MENU button while powering up the controller to enter Maintenance...

Страница 36: ...SAFETY MODE from the drop down list and press the SELECT button on the pendant keypad 3 Enter the Safety Mode password and press ENTER 4 If successful the visible mode will change to SAFETY MODE If t...

Страница 37: ...From the Main Menu tap SYSTEM then tap SETUP Select OPTION FUNCTION and press the SELECT button on the pendant keypad 1 8 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED 37...

Страница 38: ...e sure it s set to USED If not press the SELECT button 2 At the Modify prompt tap YES 3 Back in the OPTION FUNCTION menu highlight the field next to MotoPlus FUNC and set it to USED 4 VERSION 1 0 0 20...

Страница 39: ...files SRAMDRV DTA prompt tap YES 6 Save settings to the Safety I O board From the Main Menu tap FILE then tap INITIALIZE Highlight Safety Board FLASH Reset and press the SELECT button 1 9 VERSION 1 0...

Страница 40: ...can take up to 60 seconds to complete When the reset is complete the pendant will beep 2 Save settings to the PFL board collaborative robots only HighlightPFL Board FLASH Reset and press the SELECT b...

Страница 41: ...mplete When the reset is complete the pendant will beep 3 From the Main Menu tap MotoPlus APL tap FOLDER to select the folder to load files from Tap the forge os folder to open it then tap to open the...

Страница 42: ...file on the USB and press the SELECT button 1 Verify that a small black star icon appears to the left of the file name and press the ENTER button on the pendant keypad 2 At the Load prompt tap YES If...

Страница 43: ...ELECT 2 Scroll to SAFETY MODE from the drop down list and press the SELECT button on the pendant keypad 3 Enter the Safety Mode password and press ENTER 4 If successful the visible mode will change to...

Страница 44: ...se until you are out of the Monitor 5 If you made any changes restart the controller Once the controller has restarted enable Safety Mode and check again to make sure the correct application is runnin...

Страница 45: ...CT button 3 Highlight each file and press the SELECT button on the keypad so that it is marked with a star 4 Press ENTER on the keypad 5 At the Load prompt tap YES 6 VERSION 1 0 0 2021 COPYRIGHT READY...

Страница 46: ...and the pendant is set to Teach Mode go to Main Menu JOB SELECT JOB Tap the JOB tab in the upper left toolbar and choose DELETE JOB Then select the job to delete 7 From the Main Menu tap EX MEMORY the...

Страница 47: ...TA and press the SELECT button on the pendant keypad 2 Verify that the file is marked with a star 3 Press the ENTER button on the pendant keypad 4 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHT...

Страница 48: ...the EXTERNAL MEMORY DEVICE screen and then you will be returned to the EX MEMORY SCREEN 6 From the Main Menu tap EX MEMORY then tap LOAD Highlight FILE GENERAL DATA and press the SELECT button 1 10 V...

Страница 49: ...e and press SELECT Make sure the file is marked with a star 2 Press ENTER 3 At the Load prompt tap YES 4 From the Main Menu tap SAFETY FUNC then choose SPEED LIMIT 11 VERSION 1 0 0 2021 COPYRIGHT READ...

Страница 50: ...2 in the File column and press the SELECT button 1 Select the field next to FILE VALID COND and select SIGNAL 2 and press the SELECT button 2 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RE...

Страница 51: ...Tap the READBACK button on the screen 3 Tap the WRITE button on the screen 4 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED 51...

Страница 52: ...eat all sub steps in the previous step for 3 in the File column READYP OFF 12 From the Main Menu tap EX MEMORY then tap LOAD Highlight I O DATA and press the SELECT button 1 13 VERSION 1 0 0 2021 COPY...

Страница 53: ...LE YSFLOGIC DAT Note For YRC1000micro with PFL option collaborative robot also highlight and select PSEUDO INPUT SIGNAL PSEUDOIN DAT 2 Press the ENTER button on the pendant keypad 3 At the Load prompt...

Страница 54: ...CUIT Tap the WRITE button on the bottom of screen 1 Tap the CONFIRM button on the bottom of screen 2 At the Update the file prompt tap YES 3 14 From the Main Menu tap EX MEMORY then tap LOAD 15 VERSIO...

Страница 55: ...MENU when you hear the teach pendant beep 17 Change the security mode to Safety Mode again From the Main Menu select SYSTEM then SECURITY 1 Tap the field next to MODE or press SELECT 2 Scroll to SAFE...

Страница 56: ...ghlight Safety Board FLASH Reset and press SELECT 1 At the Reset prompt tap YES 2 Wait for the flash reset to complete This process can take up to 60 seconds to complete When the reset is complete the...

Страница 57: ...flash reset to complete This process will take up to 120 seconds to complete When the reset is complete the pendant will beep 3 20 Power off the YRC1000 controller and wait 10 seconds 21 Turn the Yas...

Страница 58: ...obot Forge OS attempts to communicate with the robot controller 1 When the robot connects you can add Tool Center Points TCPs or Payloads for the robot You can come back to this later by editing the d...

Страница 59: ...anel check the DCP box next to that signal Note To use these I O signals you must integrate your automation equipment with the robot controller 2 Tap SAVE 3 3 Forge OS returns to the Device Configurat...

Страница 60: ...the robot s configuration in Forge OS and save Forge creates a TOOL CND file and saves it to USB on the Yaskawa Motoman controller Load the tool file onto the controller while in the Safety mode Reset...

Страница 61: ...Payloads onto the USB attached to the Yaskawa Motoman pendant If you didn t see one before you will see a Tool Mismatch error now Note Forge OS saves the updated TCPs and Payloads to tool cnd in the...

Страница 62: ...avigate to SYSTEM INFO then SECURITY 2 Select SAFETY MODE from the drop down list 3 Enter the SAFETY MODE password and press the ENTER button on the pendant keypad 4 From the Main Menu tap EX MEMORY t...

Страница 63: ...ECT Then press ENTER 2 At the Load screen select YES 3 Power off the Yaskawa controller and wait 10 seconds 8 Power on the controller while holding the Main Menu button on the Yaskawa Motoman 9 VERSIO...

Страница 64: ...e sure that the key is still in the TEACH position fully counter clockwise 1 From the Main Menu tap SYSTEM then tap SECURITY 2 Select SAFETY MODE from the drop down list 3 Enter the SAFETY MODE passwo...

Страница 65: ...rd FLASH Reset 1 When prompted select YES 2 Wait for the reset to complete 15 20 seconds 3 Save settings to the PFL board collaborative robots only 12 VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL R...

Страница 66: ...rompt tap YES 2 Wait for the flash reset to complete This process will take up to 120 seconds to complete When the reset is complete you ll hear a beep 3 Turn the key to the REMOTE position fully cloc...

Страница 67: ...0 seconds 14 Power on the controller When Forge OS reconnects to the robot controller after the final power cycle you will be able to clear the TOOL MISMATCH warning 15 VERSION 1 0 0 2021 COPYRIGHT RE...

Страница 68: ...ur 16 digit custom safety mode password from the Collaborative Password Agreement If you do not have that on hand call Yaskawa with your Warranty ID number and they will provide it to you 1 If you are...

Страница 69: ...X MEMORY and select DEVICE If you find that the Target Device is set to read an SD card SD Pendant change the field to USB Pendant 1 If the Target Device is set to USB and you continue getting this al...

Страница 70: ...t to disabled 2 Check if you set the correct active payload correctly in Forge OS Make sure the Device Configuration provides accurate payload mass and center of mass settings for the tool 1 If using...

Страница 71: ...s and hardware integration guides check out our Support page support ready robotics com For articles whitepapers and other resources check out our Resources page ready robotics com resources For produ...

Страница 72: ...VERSION 1 0 0 2021 COPYRIGHT READY Robotics ALL RIGHTS RESERVED 72...