Reach PoE4N/10G Tester Manual 1.1
06/15/2020
Page 25
Appendix B - Test Setups
B.1
Overview
This Appendix gives an overview of basic test setups. No port or group prefixes are
shown. PSE, PD as defined in IEEE 802.3af. The RT-PoE4N/10G commands are issued
in the order shown.
B.2
Signature Detect
RT-PoE commands:
PSE check after commands issued
reset
connect on
Verify that the PSE does not see a valid PD.
detect ok
Verify that the PSE does recognize a valid PD.
detect hi
Verify that the PSE does not see a valid PD.
detect ok
cap on
Verify that the PSE does not see a valid PD.
B.3
Class Detect
RT-PoE commands:
PSE check after commands issued
reset
connect on
detect ok
class 0
Verify that the PSE sees a "class 0" PD.
class 1
Verify that the PSE sees a "class 1" PD.
class 2
Verify that the PSE sees a "class 2" PD.
class 3
Verify that the PSE sees a "class 3" PD.
class 4
Verify that the PSE sees a "class 4" PD.