Instruction manual
Page 63 / 189
Copyright © REA Elektronik
REA JET HR
pro
2K / 4K
V 3.5x_001 28.05.2015
Step 1:
Figure 61: Fastening of the sensor to the adapter plate
Step 2:
Figure 62: Fastening of the sensor with the adapter plate to the print head (front position)
Step 3:
Figure 63: Fastening of the sensor with the adapter plate to the print head (rear position)
Screw the sensor (located beneath the adapter plate) with
the two long screws
(II)
to the adapter plate.
Direction:
Please ensure that depending on the desired assembly
position (right or left on the print head), the
controls/display elements of the sensor point upward and
that they are well accessible after installing the print head.
Screw the adapter plate incl. sensor to the print head with
the two short countersunk head screws (
I
).
Attention
Only use the short countersunk
head screws (I) to fasten the
adapter plate to the print head.
Longer screws would extend into
the interior of the print head and
make it difficult to insert the
cartridge or damage one that has
already been inserted.
Controls
Controls
When using this adapter plate, the
sensor distance changes from 19
mm (valid when using the
assembly bracket) to 22 mm. This
must be taken into account in both
system settings.