Instruction manual
Page 127 / 189
Copyright © REA Elektronik
REA JET HR
pro
2K / 4K
V 3.5x_001 28.05.2015
4.2.18.2 Installation of the stripper plate
Figure 172: Earthing connection on the stripper plate
4.2.18.3 Installation of the product sensor
Figure 173: Connection for the sensor on the RA JET print header
In the delivery state, the sensor connection is sealed with a lid. To obtain the IP protection class,
only the blind cap can be removed from the print head, to which the product sensor is connected.
4.2.18.3.1
Assignment of the product sensor connection on the print header
Pin HR
Name / Function
Value
Wire color
1
Power supply for the product
sensor
+24V DC
Brown
2
Contamination message
–
Output of the sensor
(Is only available when using
sensor type 1!)
High Pegel
White/pink
(depends
on sensor
type)
3
Mass for the product sensor
GND
Blue
4
Product detected
–
Output of the sensors
High Pegel
Black
*) for standard industry sensor
Table 27: Assignment of the sensor connection to the print head
Figure 174: View of the soldering side
of connector
The earthing connection on the stripper plate is a
functional earthing connection.
The wiring is always star-shaped for the "central earthing
point" of the machine / system.
(= separate cable for each component).
It is of utmost importance to ensure the connection has
low impedance as the connection (also) is a "functional
earth" connection.
This applies to all stripper plates!
This sensor is not
galvanically isolated!
For print resolution via SPS
or the like, please use one
of the available digital