31
COMMUNICATION WITH SLAVE PRODUCTS
If you consider to install one or more products in sequence to the main unit or make the
connection in the future, refer to the pictures below to allow the communication between the
master unit and the products in sequence
.
It is recommended to use different cable colours to avoid to exchange the wiring connections.
Attention
– It is necessary to respect the wiring connection between the signals S1-C1 and S2-C2
to avoid damages to the electronic device.
CONFIGURATION OF MASTER- SLAVE
In order to configure as MASTER Unit the selected product, proceed turning on it through the
main switch “0/1” and, once energized, if it hasn’t other products turned on and connected to C1
and C2.
Once the red light is turned out, press the button “AUTO”. If the red light gives the signal
corresponding to the “AUTO” mode, the product is correctly configured as MASTER.
Once the product is configured as MASTER unit, it is possible to start with the configuration of the SLAVE
1.
DO NOT SEND ANY REMOTE COMMAND TO SLAVE PRODUCTS.
Make sure the MASTER unit starts running before turning on the next unit (SLAVE) through the
“0/1” switch in order to give time to MASTER unit to configure the SLAVE products in the desired
sequence.
Turn on, through main switch, all the SLAVE units in sequence as explained below only after that
the previous unit has actually started running.
1) Master Unit
2) Slave 1 which runs in the opposite direction of the Master
3) Slave 2 which runs in the same direction of the Master
4) Slave 3 which runs in the opposite direction of the Master ….
ATTENTION
If the product is not correctly configured (MASTER or SLAVE), the RESET function can be used. In
this way the product can be brought back to original manufacturing conditions. This procedure is
explained in the command/control manual.