UNICA
Sanitary water heat pump
27
When the E-heater button on the control panel has been turned on manually, on the display TS2 (E-heater off
temperature) appears and it can be directly modified instead of TS1 (tank setting temperature).
11.4.7
ON/OFF contact
When ON/OFF contact is closed, and the controller is ON, the unit can work and the running mode is decided by the setting of the
controller.
When ON/OFF contact is closed, but the controller is OFF, the unit can’t work.
When ON/OFF contact is opened, but the controller is ON, the unit can’t work (with the exception of external pump).
If the controller is ON, and the ON/OFF status is changed from opened to closed, the unit will work by the previous settings of the
controller (auto-restart).
If the unit was previously in stand-by, in case the ON/OFF status is changed from opened to closed, the unit remains in stand-by.
A signal/warning in case of remote OFF signal (opened contact) is displayed. In such a way the customer can understand why the
unit is not working.
11.4.8
Contact for photovoltaic plant integration
The ON/OFF contact can be configured so that a photovoltaic plant, in max production periods, can be used to obtain the max
value of hot water by the unit (set the parameter 35 to 1). When the contact is closed (activation by FV plant), the tank setting
temperature TS1 is increased to the max possible value compatibly with working limits that are indicated in Paragraph 17.
11.5
PARAMETER CHECKING AND ADJUSTMENT
Some parameters can be checked and adjusted by the controller. Below is the parameter list.
Parameter
no.
Visibility
U=user
I=installer
Description Range
Default
Remarks
0
I/U
Tank water setting temp. (TS1)
10 ~ 65°C
55°C
Adjustable (it can be also modified by
the user in normal function)
1
I
Water temp. difference TS6
2 ~ 15°C
5°C
Adjustable
2
I
E-heater off tank water temp. (TS2)
10 ~ 75°C
65°C
Adjustable
3
I
E-heater delay time
0 ~ 90
6
t * 5 min, Adjustable
4 I
Week disinfection temperature TS3
(related to
upper tank temp T3)
60 ~ 70°C
70°C
Adjustable
5
I
High temp disinfection time t2
30 ~ 90 min
30 min
Adjustable
13
I
Disinfection start up time adjusting
0~23
23
Adjustable
14
I
Pump usage selection
0/1/2
0
Adjustable
(0=disabled, 1=sanitary hot water
circulation usage, 2=solar water
circulation usage)
15
I
Water circulation temp. setting 15
~
50°C
35°C
Adjustable
16
I
Offset for sanitary hot water circulation
1 ~ 15°C
2°C
Adjustable
17
I
Water difference temp. for solar pump restart
5 ~ 20°C
5°C
Adjustable
18
I
Offset for solar water circulation
1 ~ 4°C
2°C
Adjustable
19
I
Low outside temp. electrical heater activation
0/1
1
Adjustable
0=off, 1=on
20
I
Electrical heater activation during defrosting
0/1
1
Adjustable
0=off, 1=on
21
I
Disinfection period
1 ~ 30 days
7 days
Adjustable
32
I
E-heater activation for heat pump integration
0/1
1
Adjustable
0=off, 1=on
33
I
E-heater activation hysteresis 1
~
10°C
3°C
Adjustable
35
I
ON/OFF contact configuration
0/1
0
0=on/off
1=photovoltaic
A
U
Lower tank temp T2
0 ~ 99°C
Actual testing value. Error code P1 will be shown in
case of a malfunction
B
U
Upper tank temp T3
0 ~ 99°C
Actual testing value. Error code P2 will be shown in
case of a malfunction
C
U
Coil temp.
-15 ~ 99°C
Actual testing value. Error code P3 will be shown in
case of a malfunction
D
U
Return gas temp.
-15 ~ 99°C
Actual testing value. Error code P4 will be shown in
case of a malfunction
E
U
Ambient temp.
-15 ~ 99°C
Actual testing value. Error code P5 will be shown in
case of a malfunction
F
U
Hot sanitary/solar water temp.
0 ~ 125°C
Actual testing value. Error code P6 will be shown in
case of a malfunction, no error if parameter14=0
G
U
EXV open steps
10 ~ 47 step
N*10 step
H
U
Effective water set for heat pump
10 ~ 65°C
If the working of the unit exceeds the region that is
indicated in Paragraph 17 for high water and air
temperatures, the effective water set is automatically
lowered on respect of TS1 that was set by the user.
Содержание Unica 200
Страница 2: ......
Страница 11: ...UNICA Sanitary water heat pump 9 8 OVERVIEW OF THE UNIT 8 1 PARTS AND DESCRIPTIONS ...
Страница 37: ...UNICA Sanitary water heat pump 35 19 2 CONNECTION OF AN AUXILIARY HEAT SOURCE ...
Страница 38: ...UNICA Sanitary water heat pump 36 19 3 CONNECTION OF AN AUXILIARY HEAT SOURCE BY MEANS OF AN EXTERNAL SWITCH ...
Страница 40: ...FAG0FA000BZ 00 03 2018 bit ly rdzwebsite ...