RDS loadmaster 9000i Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Loadmaster 9000i DMM

Approved Weighing System 

Operation

RDS Part No.:

Document Issue:

Software Issue:

S/DC/500-10-589 

1.1: 3/9/08 

PS 306-050 rev. 20 

 

Содержание loadmaster 9000i

Страница 1: ...Loadmaster 9000i DMM Approved Weighing System Operation RDS Part No Document Issue Software Issue S DC 500 10 589 1 1 3 9 08 PS 306 050 rev 20...

Страница 2: ...Service and Technical Support PLEASE CONTACT YOUR NEAREST DISTRIBUTOR If unknown then fax 44 0 1453 733311 for further information Our policy is one of continuous improvement and the information in th...

Страница 3: ...lope 11 ii Low Oil Temperature Sensor Faults 11 iii Crowd Bucket 11 iv Boom Sensor Telehandlers only 11 2 5 Set Target Load 11 2 6 Set Preset Tare 11 2 6 1 Cancel Preset Tare 11 2 6 2 Re weigh functio...

Страница 4: ...ds 26 4 6 1 Select Printer Output Mode 26 4 6 2 View Print Last Load Record 26 4 6 3 View Print Multiple Load Records 27 4 6 4 View Print Clear the Grand Total 28 4 6 5 Overload logging facility 29 4...

Страница 5: ...covers operation for NAWI and AWI weighing modes It does not cover use in non approved weighing mode For non approved weighing please refer to the Loadmaster 8000i instruction manual What is the diff...

Страница 6: ...crease to show how much is left to load Return to MAIN Screen Press at any time to return from the Tare screen or any other screen back to the MAIN weighing screen displayed here Numeric Keypad Used t...

Страница 7: ...tare figure can be entered up to the Maximum weight that the system is verified to i e max d Actual Scale Interval that displayed on screen Verification Scale Interval e Certification number given af...

Страница 8: ...ay functions and settings for each of the primary screen pages Text or icons are displayed adjacent to the sub menu keys to denote their function 1 9 Data Entry Alphanumeric values are entered via the...

Страница 9: ...s YES or NO and wait as the instrument is re configured You must zero after selecting the weighing mode NOTE Please refer to the Loadmaster 8000i manual for weighing in non approved mode 2 3 Zero Prom...

Страница 10: ...e symbol denotes that this is a zero done during normal operation NOTE If the live last bucket is used the dynamic zero is followed by the static zero as described below 2 4 2 Static Zero NAWI Mode Pr...

Страница 11: ...is left to load 2 6 Set Preset Tare This facility is used to display the NET weight of a product within a lifted container The normal gross weight is taken from which the pre programmed empty weight o...

Страница 12: ...be enabled from the SETUP menu ref section 5 3 1 Lower the bucket load with the remaining material 2 Press the Tare 1 key fig 15b 3 Lift to re weigh and then press ENTER The remaining material weight...

Страница 13: ...ing is inhibited The bucket weight is then displayed fig 17 and if AUTO ENTER is set as shown the weight is automatically stored in memory If MANUAL ENTER is set then PRESS the LOAD ENTER BUTTON to st...

Страница 14: ...while the weight is taken The display will show two bars which fill up indicating that the weight is being sampled fig 20 and the bucket weight is then displayed There is no AUTO ENTER option The weig...

Страница 15: ...re the instrument then reverts to the MAIN screen Only the first 3 stores can be displayed On completing the load when the CLR button is pressed the load data is automatically saved to the data card 3...

Страница 16: ...mit is exceeded This will occur 9 divisions 9 x e above the stated maximum figure that the system is certified to Weighing is inhibited in NAWI or AWI mode Example If Max weight 10 0t and e 0 05t the...

Страница 17: ...nnot be rectified re calibration is necessary 3 7 Clear Last Entry If the last bucket weight was entered in error then press the key to delete it Only the last entry can be cleared 3 8 Reset for next...

Страница 18: ...ata file LMTOTALS CSV Once each load is entered the data bucket weight total weight time date etc along with the selected store reference information in a shorthand form using just the Index No s of e...

Страница 19: ...able S CB 268 1 049 that also provides a power supply from the head unit fig 25 NOTE For more information on the printer please refer to the ICP300 printer manual 4 1 3 Software Setup for Printers in...

Страница 20: ...store Product For the reference store selected above you can then set the line position for the CE logo refer to the following section Reference text order Setup For each Reference store listed on the...

Страница 21: ...Print record LMSETUP CSV Main Configuration file for the instrument LM9KTOTL CSV REFDAT01 CSV REFDAT02 CSV REFDAT03 CSV REFDAT04 CSV REFDAT05 CSV REFDAT06 CSV TICKET NUM This file is necessary for th...

Страница 22: ...s Centre Ryeford Glos GL6 8WS Tel Fax 01453 866677 8 0 Styles and Allen Ltd The Old Coachhouse Witney Glos GL11 3FG Tel 01689 453332 Fax 01689 453330 The information in the Extended Reference field of...

Страница 23: ...ht in the Truck Store otherwise ignore line 2 6 If the CE logo is required on printouts move the cursor to the Logo line and press the key Then press the key until CE is displayed and press the ENTER...

Страница 24: ...TL CSV file Figure 31 Load Data File Example CN CN THIS FILE LOGGED VIA AN RDS PCMCIA ADAPTOR v502 027 CN 0 2 1 0 0 0 6 28 10 04 16 26 A 0 1 0 19 2 4 8 4 8 4 8 4 8 1 2 3 4 0 0 5 28 10 04 17 10 A 0 1 0...

Страница 25: ...2 06 14 45 16 02 06 14 46 35 0 1 1 16 27 Load Ticket Print Record 10 T 2 5 3 4 0 0 0 16 02 06 14 45 16 02 06 14 45 33 A 0 1 0 16 27 5 45 4 19 6 63 Ticket No T Ticket Job No Ref 1 Ref 2 Ref 3 Ref 4 Ref...

Страница 26: ...is printed on the ticket only when in Customer mode A lift record is printed out automatically to the printer and card module after each entered lift Each lift record is saved to the card automatical...

Страница 27: ...ave two options to specify the store indexes s for store 1 store 1 is PRODUCT in this example The default setting is Any the instrument will search for records for all products within the Date Time sp...

Страница 28: ...89 3 Between the dates 16 11 28 04 04 and 15 11 29 04 04 4 6 4 View Print Clear the Grand Total Press the STOR key twice From the Grand Totals line fig 42 press MEM to view the grand total number of l...

Страница 29: ...on the GRAND TOTAL page fig 35 It is reset when you press the CLR button 4 6 6 View Print the 7 day Total From the GRAND TOTAL screen fig 43 press the key to view the daily totals of the last seven da...

Страница 30: ...TE The screen may darken slightly at higher temperatures e g if it is exposed directly to bright sunlight This is a normal characteristic of this type of display 5 2 Set Time and Date From the SETUP s...

Страница 31: ...the ticket numbers will be different but the job number stays the same If for whatever reason the head unit needs replacing both job number and ticket number can be edited to continue from the last n...

Страница 32: ...9000 instrument to enable you to switch to non approved mode LM8000 as required 6 Other Information Screens 6 1 Diagnostics Please refer to the installation manual 6 2 Helpline Contact details for any...

Страница 33: ...format shown at the top of each print A typical file is shown below OE LM9000 RDS Loadmaster 9000 ID Company Name ID 2 Road Town Region Post Code Tel Fax Icon1 8 8 24 24 0 102 102 0 219 219 Icon2 8 7...

Страница 34: ...34 Document History Issue 1 0 28 1 08 Original Issue based on UK506 3 DOC Issue 1 1 3 9 08 Minor corrections ref WB...

Отзывы: